Запасные части Pepperl+Fuchs
Каталожный номер: 291627
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.75 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | Multihole-LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291609
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 4 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.75 |
| Reduction factor rBrass | 0.49 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 450 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Cable version | 3 x 0.14 mm2 |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291611
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 4 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 3.04 mm ( -40 ... -25 °C (-40 ... -13 °F) ) |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.7 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 450 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | Multihole-LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291617
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291619
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | Multihole-LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291621
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 12 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 9.72 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 10 mA |
| Switching state indicator | all direction LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291623
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 12 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 9.72 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... mm ( -40 ... -25 °C (-40 ... -13 °F) ) |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291637
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 25 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 20.25 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.8 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 10 mA |
| Switching state indicator | all direction LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291639
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 25 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 20.25 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 19 mm ( -40 ... -25 °C (-40 ... -13 °F) ) |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.8 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291631
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.5 |
| Reduction factor r304 | 0.75 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | Multihole-LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291629
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.5 |
| Reduction factor r304 | 0.75 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 291613
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.45 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 450 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 16 mA |
| Switching state indicator | all direction LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 hex nuts included |
Каталожный номер: 95096
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.6 ... 2.6 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.1 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | Cage tension spring terminals |
| Core cross-section (system side) | up to 2.5 mm2 |
| Connection (valve side) | Cage tension spring terminals |
| Core cross-section (valve side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP20 |
Каталожный номер: 44565
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.6 ... 2.6 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.1 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Core cross-section (system side) | up to 2.5 mm2 |
| Core cross-section (valve side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP20 |
| Note | Installation in housing |
Каталожный номер: 95098
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.6 ... 2.6 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.1 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | Cage tension spring terminals |
| Core cross-section (system side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP20 |
Каталожный номер: 44567
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.6 ... 2.6 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.1 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP20 |
Каталожный номер: 104533
| General specifications |
|---|
| Switching function | 2 x normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.7 ... 3.3 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.2 |
| Reduction factor rBrass | 0.63 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | Cage tension spring terminals |
| Core cross-section (system side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 3G |
Каталожный номер: 104485
| General specifications |
|---|
| Switching function | 2 x normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.7 ... 3.3 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.2 |
| Reduction factor rBrass | 0.63 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow can be switched off by of DB1 |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | Cage tension spring terminals |
| Core cross-section (system side) | up to 2.5 mm2 |
| Connection (valve side) | Cage tension spring terminals |
| Core cross-section (valve side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| General information |
|---|
| Use in the hazardous area | see instruction manual
|
| Category | 1G 2G 3G |
Каталожный номер: 44570
| General specifications |
|---|
| Switching function | 2 x normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.6 ... 2.6 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.2 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow can be switched off by of DB1 |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | screw terminals |
| Core cross-section (system side) | up to 2.5 mm2 |
| Connection (valve side) | screw terminals |
| Core cross-section (valve side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Note | Installation in housing |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G |
Каталожный номер: 95100
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.6 ... 2.6 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.1 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | Cage tension spring terminals |
| Core cross-section (system side) | up to 2.5 mm2 |
| Connection (valve side) | Cage tension spring terminals |
| Core cross-section (valve side) | up to 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP20 |
Каталожный номер: 97927
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Installation | |
| Output polarity | DC |
| Inside diameter | 15 mm |
| Measuring cone | 6 mm |
| Material | 1.4401 |
| Passage speed | &le 10 m/s |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Output voltage | |
| Traverse A | 1 V |
| Traverse B | UB - 3 V |
| Power ON | 1 V |
| Voltage drop | &le 1.5 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 10 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Cable diameter | 3 mm |
| Housing material | PBT |
| Degree of protection | IP67 |
Каталожный номер: 180779
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Inside diameter | 10 mm |
| Measuring cylinder | |
| Diameter | 2.5 mm |
| Length | 4 mm |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 6150 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 187456
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Inside diameter | 10 mm |
| Measuring cone | 4 mm, 1.4305 / AISI 303 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 2000 Hz |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 6150 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m Crimp terminal sockets 60888-3, AMP |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| Mass | 36 g |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 95902
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Inside diameter | 10 mm |
| Measuring cone | 4 mm, 1.4305 / AISI 303 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 2000 Hz |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 6150 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 150 mm Crimp terminal sockets 60888-3, AMP |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Mass | 18 g |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 51666
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR, bistable |
| Inside diameter | 10 mm |
| Measuring cylinder | |
| Diameter | 2.5 mm |
| Length | 3 mm |
| Measuring cone | |
| Material | 9S20K |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Hysteresis | typ. 1 % |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | |
| Traverse B | 3 mA |
| Traverse A | 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 2144 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165F |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 110970
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR, bistable |
| Inside diameter | 10 mm |
| Measuring cylinder | |
| Diameter | 2.5 mm |
| Length | 3 mm |
| Measuring cone | |
| Material | 9S20K |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Hysteresis | typ. 1 % |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | |
| Traverse B | 3 mA |
| Traverse A | 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 115614
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR, bistable |
| Inside diameter | 10 mm |
| Measuring cylinder | |
| Diameter | 1/8" (3.175mm) |
| Measuring cone | Carboloy |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Hysteresis | typ. 1 % |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | |
| Traverse B | 3 mA |
| Passage B UB=8V | &ge 3 mA |
| Passage B UB=10V | &ge 4.2 mA |
| Traverse A | 1 mA |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 187454
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR, bistable |
| Inside diameter | 10 mm |
| Measuring cone | 4 mm, 1.4401 |
| Passage speed | &le 10 m/s |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Hysteresis | typ. 1 % |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | |
| Passage B UB=8V | &ge 3 mA |
| Passage B UB=10V | &ge 4.2 mA |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10 |
| Functional safety related parameters |
|---|
| MTTFd | 2130 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 150 mm Crimp terminal sockets 60888-3, AMP |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Mass | 20 g |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 187455
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR, bistable |
| Inside diameter | 10 mm |
| Measuring cone | 4 mm, 1.4401 |
| Passage speed | &le 10 m/s |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Hysteresis | typ. 1 % |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | |
| Passage B UB=8V | &ge 3 mA |
| Passage B UB=10V | &ge 4.2 mA |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10 |
| Functional safety related parameters |
|---|
| MTTFd | 2130 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m Crimp terminal sockets 60888-3, AMP |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| Mass | 36 g |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106545
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR, bistable |
| Installation | non-flush |
| Inside diameter | 10 mm |
| Measuring cylinder | |
| Diameter | 1/8" (3.175mm) |
| Measuring cone | Carboloy/high grade steel |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Hysteresis | typ. 1 % |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | |
| Traverse B | 3 mA |
| Traverse A | 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.