Запасные части Pepperl+Fuchs
Каталожный номер: 106617
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Installation | |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 3000 Hz |
| Hysteresis | 0.1 ... 0.4 mm |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 123054
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Installation | |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 3000 Hz |
| Hysteresis | 0.41 ... 0.6 mm |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT/PPS |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106593
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Installation | |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 0.41 ... 0.8 |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 13520 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 220 mm with connector sleeves , 7 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT/PPS |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106600
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Installation | |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 3000 Hz |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 220 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT/PPS |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106584
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 3000 Hz |
| Hysteresis | 0 ... 0.05 mm |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 11150 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT/PPS |
| Degree of protection | IP67 |
| Equipment protection level Da |
|---|
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 303205
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NAMUR with safety function |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Reference target | 10 x 7 x 0.3 mm3, Al |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | with NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) |
| Suitable for 2:1 technology | yes , with reverse polarity protection diode |
| Rate of current rise | 2.1 mA / mm |
| Current consumption | |
| Measuring plate not detected | 0.2 ... 1 mA |
| Measuring plate detected | &ge 3 mA |
| Functional safety related parameters |
|---|
| MTTFd | 11850 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standard conformity |
|---|
| EMC in accordance with | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165F |
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Note | only for non-ferrous metal Adjustable stop |
| Data for application in connection with hazardous areas |
|---|
| Equipment protection level | Ga , Gb , Gc (ic) , Da Mb |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
Каталожный номер: 303204
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR with safety function |
| Slot width | 3.5 mm |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
| Reference target | 10 x 7 x 0.3 mm3, Al |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V |
| Switching frequency | 0 ... 3000 Hz |
| Hysteresis | with NAMUR switch amplifier: 0.09 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) |
| Suitable for 2:1 technology | yes , with reverse polarity protection diode |
| Rate of current rise | -4.5 mA / mm |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | 0.2 ... 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 11800 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standard conformity |
|---|
| EMC in accordance with | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -50 ... 100 °C (-58 ... 212 °F) Safety application: -40 ... 100°C |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Note | adjustable stop Security relevant only up to -40°C |
| Data for application in connection with hazardous areas |
|---|
| Equipment protection level | Ga , Gb , Gc (ic) , Da Mb |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
Каталожный номер: 820
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Slot width | 30 mm |
| Depth of immersion (lateral) | 27 ... 31 mm |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 150 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | ABS |
| Degree of protection | IP67 |
Каталожный номер: 47
| Описание оборудования |
|---|
| Mounting flange, 8 mm |
Каталожный номер: 836
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Slot width | 30 mm |
| Depth of immersion (lateral) | 27 ... 31 typ. |
| Installation | |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 150 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 6 m |
| Core cross-section | 0.75 mm2 |
| Housing material | ABS |
| Degree of protection | IP67 |
Каталожный номер: 263361
| Описание оборудования |
|---|
| Activator for F31 series |
Каталожный номер: 84420
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Slot width | 30 mm |
| Depth of immersion (lateral) | 27 ... 31 mm |
| Installation | |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 65 V DC |
| Switching frequency | 0 ... 150 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | ABS |
| Degree of protection | IP67 |
Каталожный номер: 259055
| Описание оборудования |
|---|
| Activator for F31 series |
Каталожный номер: 26178
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Slot width | 30 mm |
| Depth of immersion (lateral) | 27 ... 31 typ. |
| Installation | |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 150 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | ABS |
| Degree of protection | IP67 |
Каталожный номер: 106616
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 30 mm |
| Depth of immersion (lateral) | 27 ... 30 mm |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | 0.1 ... 0.3 mm |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 11060 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | ABS |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| Mass | 450 g |
| Equipment protection level Da |
|---|
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106604
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 5 mm |
| Depth of immersion (lateral) | 5 ... 7 mm , typ. 6 mm |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 0.05 ... 0.65 mm |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 9060 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LiY , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Equipment protection level Da |
|---|
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106605
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 5 mm |
| Depth of immersion (lateral) | 8 ... 10 mm , typ. 9 mm |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 0.05 ... 0.3 mm |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 4560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| Equipment protection level Da |
|---|
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106606
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Slot width | 5 mm |
| Depth of immersion (lateral) | 8 ... 10 typ. 9 mm |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 4560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 6 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| Equipment protection level Da |
|---|
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 293307
| General specifications |
|---|
| Slot width | 5 mm |
| Depth of immersion (lateral) | 5 ... 7 mm , typ. 6 mm |
| Output polarity | NAMUR |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 0.05 ... 0.65 mm |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 9060 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads PTFE , 500 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Data for application in connection with hazardous areas |
|---|
| Equipment protection level | Ga , Gb , Da , Mb |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
Каталожный номер: 306607
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 3 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.7 ... 3.3 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.2 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | all connections |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 780 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | PVC cable with stainless steel (V4A) connector M12x1 , L = 1.5 m |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
Каталожный номер: T2145
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Actual operating distance | 9 ... 11 mm typ. 10 mm |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.66 |
| Reduction factor rBrass | 0.33 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.8 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 0.9 ... 2.5 V typ. 1.7 V |
| Voltage drop IL = 100 mA, switching element on | 1 ... 2.6 V typ. 1.8 V |
| Voltage drop IL = 200 mA, switching element on | 1.2 ... 2.8 V typ. 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.01 mA |
| No-load supply current | &le 9 mA |
| Switching state indicator | - |
| Standard conformity |
|---|
| Standards | IEC / EN 60947-5-2:2004 |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP68 |
Каталожный номер: T1403
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm |
| Installation | flush |
| Assured operating distance | 0 ... 2.4 mm |
| Actual operating distance | 2.7 ... 3.3 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | typ. 0.2 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Limit data |
|---|
| Tightening torque, fastening screws | 0.4 Nm |
| Standard conformity |
|---|
| Standards | EN 50044 |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
Каталожный номер: 210621
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 4 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.88 mm |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 0 mm |
| B | 0 mm |
| C | 15 mm |
| F | 15 mm |
| Operating voltage | 10 ... 36 V DC |
| Switching frequency | 0 ... 50 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 12 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Indicators/operating means |
|---|
| Potentiometer | sensitivity adjustment |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | stainless steel 1.4404 / AISI 316L |
| Sensing face | PEEK |
| Housing diameter | 12 mm |
| Degree of protection | IP65 |
Каталожный номер: 210620
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 4 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.88 mm |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 0 mm |
| B | 0 mm |
| C | 15 mm |
| F | 15 mm |
| Operating voltage | 10 ... 36 V DC |
| Switching frequency | 0 ... 50 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 12 mA |
| Switching state indicator | LED, yellow |
| Indicators/operating means |
|---|
| Potentiometer | sensitivity adjustment |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | stainless steel 1.4404 / AISI 316L |
| Sensing face | PEEK |
| Housing diameter | 12 mm |
| Degree of protection | IP65 |
Каталожный номер: 237036
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1 ... 8 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 1.5 V |
| Temperature drift | max. 20 % at -5 ... 55 °C (23 ... 131 °F) |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 18 mA |
| Indicators/operating means |
|---|
| LED green | Operating display |
| LED yellow | indication switching state |
| Potentiometer | sensitivity adjustment |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
Каталожный номер: 237038
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1 ... 8 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 1.5 V |
| Temperature drift | max. 20 % at -5 ... 55 °C (23 ... 131 °F) |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 18 mA |
| Indicators/operating means |
|---|
| LED green | Operating display |
| LED yellow | indication switching state |
| Potentiometer | sensitivity adjustment |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
Каталожный номер: 51979
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 7 mm |
| Nominal ratings |
|---|
| Installation conditions | |
| B | 5 mm |
| C | 20 mm |
| F | 20 mm / 50 mm |
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 5 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 0.8 ... 2.2 V typ. 1.4 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.01 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1210 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
Каталожный номер: 198431
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 12 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 9.5 mm |
| Nominal ratings |
|---|
| Installation conditions | |
| B | 15 mm |
| C | 30 mm |
| F | 45 mm / 60 mm |
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 20 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 50 µA typ. 5 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1370 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 3.1 m |
| Core cross-section | 0.34 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.