| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 30 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 24.3 mm | |
| Actual operating distance | 27 ... 33 mm typ. | |
| Reduction factor rAl | 0.31 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.74 | |
| Reduction factor rBrass | 0.31 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 5 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1170 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| Protection class | II | |
| Rated insulation voltage | 253 V | |
| Rated impulse withstand voltage | 4000 V | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP69K | |
| Mass | 130 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 15 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.2 mm | |
| Actual operating distance | 13.5 ... 16.5 mm typ. | |
| Reduction factor rAl | 0.38 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.68 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 60 V DC | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | 1 ... 10 typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 5 V | |
| Operating current | 2 ... 100 mA | |
| Lowest operating current | 2 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| Switching state indicator | all direction LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Equipment protection level Gc (nA) | ||
| Certificate of Compliance | PF 15CERT3754 X | |
| Special conditions | ||
| Protection against transients | Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded. | |
| Equipment protection level Dc (tc) | ||
| Instruction | Manual electrical apparatus for hazardous areas | |
| Device category 3D | for use in hazardous areas with combustible dust | |
| Certificate of Compliance | PF 15CERT3774 X | |
| CE marking | [*PD-Z02586A*] | |
| ATEX marking | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. | |
| Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
| General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
| Installation, commissioning | Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! | |
| Maintenance | No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. | |
| Special conditions | ||
| Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
| Maximum operating voltage UBmax | The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. | |
| Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
| at UBmax=60 V, IL=100 mA | 54 °C (129.2 °F) | |
| at UBmax=60 V, IL=50 mA | 59 °C (138.2 °F) | |
| at UBmax=60 V, IL=25 mA | 62 °C (143.6 °F) | |
| at UBmax=30 V, IL=5 mA | 64 °C (147.2 °F) | |
| Protection from mechanical danger | The sensor must not be exposed to ANY FORM of mechanical danger. | |
| Protection from UV light | The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. | |
| Protection of the connection cable | The connection cable must be prevented from being subjected to tension and torsional loading. | |
| Electrostatic charge | Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 3G 3D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, red | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PA | |
| Degree of protection | IP67 | |
| Note | Use a stop screw combined with a model -F2 sensor from Pepperl+Fuchs GmbH. The maximum actuation speed of the control slide is 0.1 m/s | |
| Описание оборудования | ||
|---|---|---|
| Inductive sensor | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 15 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actual operating distance | 13.5 ... 16.5 mm typ. | |
| Reduction factor rAl | 0.38 | |
| Reduction factor rCu | 0.36 | |
| Reduction factor r304 | 0.7 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | 1 ... 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | no | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 3810 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | Two-wire | |
| Rated operating distance | 25 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 20 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Nominal ratings | ||
| Operating voltage | 3.5 ... 30 V | |
| Switching frequency | 500 Hz | |
| Reverse polarity protection | reverse polarity-conductive | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3.5 V | |
| Temperature drift | ± 15% | |
| Operating current | 2 ... 100 mA | |
| Off-state current | typ. 0.8 mA | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 25 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 20 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.5 | |
| Reduction factor r304 | 0.6 ... 1 | |
| Mounting angle | Al | |
| Amplifier housing | Stainless steel | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | 0.3 ... 5 typ. 2 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 7515 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 250 °C (32 ... 482 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Cable version | PFA cable, with armour of stainless steel | |
| Core cross-section | 3 x 0.34 , screened | |
| Housing material | PTFE / Al / 1.4305 / AISI 303 | |
| Sensing face | PTFE | |
| Degree of protection | amplifier IP67 sensor IP40 | |
| Cable length | L = 15 m | |
| Note | - amplifier 0 °C ... 70 °C - r1.4305 dep. on thickness of measurement plate d: r1.4305 = 1 for d < 1mm Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 4.05 mm | |
| Actuating element | Nonferrous targets | |
| Reduction factor rAl | 1 | |
| Reduction factor rCu | 1.1 | |
| Reduction factor r304 | 0 | |
| Reduction factor r316Ti | 0 | |
| Reduction factor rSt37 | 0 | |
| Reduction factor rBrass | 0.9 | |
| Nominal ratings | ||
| Operating voltage | 6 ... 30 V DC | |
| Switching frequency | 30 Hz | |
| Hysteresis | 3 ... 15 typ. 5 % | |
| Reverse polarity protection | yes | |
| Short-circuit protection | no | |
| Voltage drop | &le 5.5 V DC | |
| Operating current | 2 ... 100 mA | |
| Off-state current | &le 1 mA | |
| Indicators/operating means | ||
| Operation indicator | 4-way LED | |
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | Stainless steel 1.4305 / AISI 303 | |
| Housing diameter | 18 mm | |
| Degree of protection | IP67 / IP68 / IP69K - cordset dependent according to cable specification | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 25 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 20 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.5 | |
| Reduction factor r304 | 0.6 ... 1 | |
| Mounting angle | Al | |
| Amplifier housing | Stainless steel | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | 0.3 ... 5 typ. 2 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 7515 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 250 °C (32 ... 482 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Cable version | PFA cable, with armour of stainless steel | |
| Core cross-section | 3 x 0.34 , screened | |
| Housing material | PTFE / Al / 1.4305 / AISI 303 | |
| Sensing face | PTFE | |
| Degree of protection | amplifier IP67 sensor IP40 | |
| Cable length | L = 10 m | |
| Note | - amplifier 0 °C ... 70 °C - r1.4305 dep. on thickness of measurement plate d: r1.4305 = 1 for d < 1mm Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Reduction factor rBrass | 0.63 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2114 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 180 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
| Note | Installation in housing | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 3D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 5 mm | |
| Installation | flush | |
| Output polarity | AC/DC | |
| Assured operating distance | 0 ... 4.05 mm | |
| Actuating element | Ferrous targets | |
| Reduction factor rAl | 0 | |
| Reduction factor rCu | 0 | |
| Reduction factor r304 | 0.4 - 0.7 | |
| Reduction factor rSt37 | 1 | |
| Reduction factor rBrass | 0 | |
| Nominal ratings | ||
| Operating voltage DC | 20 ... 300 V | |
| Operating voltage AC | 20 ... 250 V | |
| Switching frequency | 15 Hz | |
| Hysteresis | 3 ... 15 typ. 5 % | |
| Reverse polarity protection | yes | |
| Short-circuit protection | yes | |
| Voltage drop | &le 7 V | |
| Operating current | 8 ... 200 mA | |
| Off-state current | &le 1.3 mA | |
| Error indicator | LED, green/yellow (Alternate Flashing) - Short circuit/overload indication | |
| Indicators/operating means | ||
| Operation indicator | Dual LED | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 1/2"-20 UN , 3-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | Stainless steel 1.4305 / AISI 303 | |
| Housing diameter | 18 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.45 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| No-load supply current | &le 3 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2114 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
| Note | Mounted on mechanical drive | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| No-load supply current | &le 3 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2114 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 16 m | |
| Cable version | 4 x 0.34 mm2 | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 611 g | |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
| Note | Mounted on mechanical drive | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 2 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 1.62 mm | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V | |
| Operating voltage | 5 ... 15 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 2.7 mA | |
| Measuring plate detected | &le 1.8 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 65 °C (14 ... 149 °F) | |
| Mechanical specifications | ||
| Connection type | Solder connection | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | 10 mm | |
| Degree of protection | IP67 | |
| Описание оборудования | ||
|---|---|---|
| AS-Interface | ||
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| No-load supply current | &le 3 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2114 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Cable version | 4 x 0.34 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | 10 m, PVC cable | |
| Core cross-section (system side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | PVC cable , 5 m | |
| Core cross-section (system side) | 0.75 mm2 | |
| Connection (valve side) | PVC cable , 0.5 m | |
| Core cross-section (valve side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 2 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 1.62 mm | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. % | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 65 °C (14 ... 149 °F) | |
| Mechanical specifications | ||
| Core cross-section | 0.14 mm2 | |
| Housing material | PA | |
| Housing diameter | 10 mm | |
| Degree of protection | IP67 | |
| Описание оборудования | ||
|---|---|---|
| Relay output | ||
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | 4-pin, M12 x 1 connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Connector Rd24 x 1/8 , 7-pin | |
| Connection (valve side) | PVC cable , 0.5 m | |
| Core cross-section (valve side) | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | V16-connector | |
| Connection (valve side) | 1 connector V1 (M12 x 1) | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
Индуктивный датчик Inductive sensor 921LC5 Pepperl+Fuchs снят с производства.
Замена: Индуктивный датчик Inductive sensor NBN5-11K8-N-V8 Pepperl+Fuchs
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 5 mm | |
| Installation | non-flush | |
| Assured operating distance | 0 ... 4.05 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.6 | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V | |
| Operating voltage | 5 ... 15 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 2.7 mA | |
| Measuring plate detected | &le 1.8 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Solder connection | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | 10 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Connector Rd24 x 1/8 , 7-pin | |
| Connection (valve side) | socket connector Rd24 x 1/8 , 7-pin | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | V18 connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 °C). The temperature range specified here (up to +100°C) only applies to sensors with part no. 2239**. | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | V18 connector | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 5 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 4.05 mm | |
| Nominal ratings | ||
| Operating voltage | 4.75 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Voltage drop | &le 1 V | |
| Temperature drift | ± 15% | |
| Operating current | 0 ... 25 mA | |
| No-load supply current | &le 10 mA | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 65 °C (14 ... 149 °F) | |
| Mechanical specifications | ||
| Housing material | Polyamides | |
| Housing diameter | 10.8 mm | |
| Описание оборудования | ||
|---|---|---|
| Relay output | ||
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.3 | |
| Reduction factor rBrass | 0.6 | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 3 kHz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1470 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm | |
| Core cross-section (system side) | rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2 | |
| Connection (valve side) | like connection (system side) | |
| Core cross-section (valve side) | like core cross-section (system side) | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Tightening torque, housing screws | 1 Nm | |
| Tightening torque, cable gland | M20 x 1.5 max. 7 Nm | |
| Note | LED switch-off | |
| Equipment protection level Gb | ||
| Special conditions | ||
| Lead insertion | The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also IEC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of IEC 60079-14, must be used. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.