General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC , safe galvanic isolation per EN 50178 | |
Power consumption | max. 3 W | |
Linearity | ± 0.5 LSB (12 Bit) , ± 2 LSB (16 Bit) | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | Ethernet Powerlink | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 5-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Operating temperature | -40 ... 79 °C (-40 ... 174.2 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Mass | approx. 700 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Tightening torque, fastening screws | max. 1.8 Nm | |
Shaft load | ||
Angle offset | ± 0.9 ° | |
Axial offset | static: ± 0.3 mm, dynamic: ± 0.1 mm | |
Radial offset | static: ± 0.5 mm, dynamic: ± 0.2 mm |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | max. 4 W | |
Linearity | ± 0.5 LSB (12 Bit) , | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | TCP/IP | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 MBit/s / 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 5-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | 0 ... 60 °C (32 ... 140 °F) Standard , with Option T 40 ... 85 °C (104 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Mass | approx. 700 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Tightening torque, fastening screws | max. 1.8 Nm | |
Shaft load | ||
Angle offset | ± 0.9 ° | |
Axial offset | static: ± 0.3 mm, dynamic: ± 0.1 mm | |
Radial offset | static: ± 0.5 mm, dynamic: ± 0.2 mm |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10 | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | EtherCAT CoE (CANopen over EtherCAT, according to CiA DS-301 and DS-406 device profile CiA) | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 ... 100 MBit/s | |
Connection | ||
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Marking | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Output type | Analog voltage output | |
Installation | quasi flush | |
Output polarity | DC | |
Measurement range | 0 ... 6 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Limit frequency (3dB) | 1000 Hz at s = 3 mm | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Repeat accuracy | 0 ... 1 µm | |
No-load supply current | &le 10 mA | |
Analog output | ||
Output type | 0 ... 5 V | |
Load resistor | &ge 500 &Omega | |
Temperature drift | ± 5 % (0 ... 70 °C) ± 10 % (-25 ... 0 °C) | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | chromium plated brass | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC , safe galvanic isolation per EN 50178 | |
Power consumption | max. 2.5 W | |
Linearity | ± 0.5 LSB ( up to 12 Bit ) ± 2 LSB ( up to 16 Bit ) | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | EtherCAT CoE (CANopen over EtherCAT, according to CiA DS-301 and DS-406 device profile CiA) | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 MBit/s / 100 MBit/s | |
Cycle time | &ge 65 µs | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP65 (without shaft seal)/ IP66/67 (with shaft seal) housing side: IP66/67 Stainless steel version (INOX): completely IP66/67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Shaft dimensions | &empty6f6 mm x 10 mm or &empty10h8 mm x 20 mm | |
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel 1.4305 / AISI 303 flange: stainless steel 1.4301 / AISI 304 shaft: stainless steel 1.4305 / AISI 303 | |
Mass | approx. 370 g (combination 1) approx. 840 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | max. 4 W | |
Linearity | ± 0.5 LSB (12 Bit) , | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | EtherNet/IP | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 Stainless steel version (INOX): completely IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel 1.4305 / AISI 303 flange: stainless steel 1.4301 / AISI 304 shaft: stainless steel 1.4305 / AISI 303 | |
Mass | approx. 370 g (combination 1) approx. 840 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10 | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | max. 4 W | |
Linearity | ± 2 LSB ( up to 16 Bit ) | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFINET IO | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 100 MBit/s | |
Cycle time | &le 1 ms (IRT) &le 10 ms (RT) | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 Stainless steel version (INOX): completely IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel 1.4305 / AISI 303 flange: stainless steel 1.4301 / AISI 304 shaft: stainless steel 1.4305 / AISI 303 | |
Mass | approx. 370 g (combination 1) approx. 840 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC , safe galvanic isolation per EN 50178 | |
Power consumption | max. 3 W | |
Linearity | ± 0.5 LSB (12 Bit) , ± 2 LSB (16 Bit) | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | Ethernet Powerlink | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 5-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Mass | approx. 700 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 80 N |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NPN | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1400 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR 2 m | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 3 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | max. 4 W | |
Linearity | ± 0.5 LSB ( up to 12 Bit ) ± 2 LSB ( up to 16 Bit ) | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | TCP/IP | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 MBit/s / 100 MBit/s | |
Connection | ||
Connector | Ethernet: 1 socket M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 5-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | 0 ... 60 °C (32 ... 140 °F) Standard , with Option T -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Mass | approx. 700 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 120 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 270 mA at 10 V DC max. 115 mA at 24 V DC | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFINET | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 100 MBit/s | |
Cycle time | &le 1 ms (IRT) , &le 10 ms (RT) | |
Connection | ||
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NPN | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1400 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 300 mm | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 3 mm | |
Degree of protection | IP67 |
Functional safety related parameters | ||
---|---|---|
MTTFd | 110 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 140 mA | |
Power consumption | &le 2.5 W , without output drivers | |
Linearity | ± 0.5 LSB | |
Output code | Gray code, binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) | |
Code preparation time | 0.3 ms | |
Interface | ||
Interface type | Push-pull, parallel , short-circuit protected | |
Resolution | ||
Multiturn | 25 Bit | |
Load current | 20 mA | |
Voltage drop | &le 2.5 V | |
Signal voltage | ||
High | operating voltage minus voltage drop | |
Low | &le 2.8 V | |
Rise time | 300 ns | |
De-energized delay | 300 ns | |
Code change frequency | 400 kHz | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | &ge 1 ms | |
Switch-off delay | &ge 1 ms | |
Input 2 | ||
Input type | Temporary storage (LATCH) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 0.1 ms | |
Switch-off delay | < 0.1 ms | |
Input 3 | ||
Input type | zero-set (PRESET) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 1 ms | |
Connection | ||
Connector | type 9426, 26-pin | |
Cable | &empty9 mm, 15 x 2 x 0.14 mm2, 2 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) cable models: -30 ... 70 °C (rigid wiring) -5 ... 70 °C (flexible wiring) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) (cable models: -5 ... 70 °C) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 400 g (combination 1) approx. 800 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 5 Ncm |
Functional safety related parameters | ||
---|---|---|
MTTFd | 110 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 140 mA | |
Power consumption | &le 2.5 W , without output drivers | |
Linearity | ± 0.5 LSB | |
Output code | Gray code, binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) | |
Code preparation time | 0.3 ms | |
Interface | ||
Interface type | Push-pull, parallel , short-circuit protected | |
Resolution | ||
Multiturn | 25 Bit | |
Load current | 20 mA | |
Voltage drop | &le 2.5 V | |
Signal voltage | ||
High | operating voltage minus voltage drop | |
Low | &le 2.8 V | |
Rise time | 300 ns | |
De-energized delay | 300 ns | |
Code change frequency | 400 kHz | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Input 2 | ||
Input type | Temporary storage (LATCH) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 0.1 ms | |
Switch-off delay | < 0.1 ms | |
Input 3 | ||
Input type | zero-set (PRESET) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 1 ms | |
Connection | ||
Connector | type 9426, 26-pin | |
Cable | &empty9 mm, 15 x 2 x 0.14 mm2, 2 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) cable models: -30 ... 70 °C (rigid wiring) -5 ... 70 °C (flexible wiring) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) (cable models: -5 ... 70 °C) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 400 g (combination 1) approx. 800 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 5 Ncm | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NPN | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1400 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m black | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 3 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Multiturn absolute encoder | |
Measurement range | min. 0 ... 22.5 ° max. 16 x 360 ° | |
Resolution | 16 Bit (12 bits/revolution) | |
Functional safety related parameters | ||
MTTFd | 566 a at 40 °C | |
Mission Time (TM) | 20 a | |
Electrical specifications | ||
Operating voltage | 15 ... 30 V DC , PELV | |
Current consumption | typ. 40 mA | |
Input 1 | ||
Input type | lower limit of measurement range (Set 1) | |
Signal voltage | ||
High | 15 ... 30 V DC | |
Input 2 | ||
Input type | upper limit of measurement range (Set 2) | |
Signal voltage | ||
High | 15 ... 30 V DC | |
Analog output | ||
Output type | 1 analog output, current | |
Default setting | rising ramp at ccw rotation | |
Linearity error | &le 0.15 % | |
Load resistor | max. 500 &Omega Max. value for operating voltage 15 V. For higher operating voltage higher load resistance can be used. | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2, 1 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Marking | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 70 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Power consumption | max. 2.5 W | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 IP66 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-30 , no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 600 g (combination 1) approx. 1200 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Tightening torque, fastening screws | max. 1.8 Nm | |
Shaft load | ||
Angle offset | ± 0.9 ° | |
Axial offset | static: ± 0.3 mm, dynamic: ± 0.1 mm | |
Radial offset | static: ± 0.5 mm, dynamic: ± 0.2 mm |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NPN | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1300 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 3 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 70 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Current consumption | max. 230 mA at 10 V DC, max. 100 mA at 24 V DC | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -30 ... 55 °C (-22 ... 131 °F) | |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Mass | approx. 600 g (combination 1) | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Tightening torque, fastening screws | max. 1.8 Nm | |
Shaft load | ||
Angle offset | ± 0.9 ° | |
Axial offset | static: ± 0.3 mm, dynamic: ± 0.1 mm | |
Radial offset | static: ± 0.5 mm, dynamic: ± 0.2 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2009 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 37 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Cable | &empty9.6 mm, 7-core | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 190 mA | |
Linearity | ± 1 LSB | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | 13 Bit | |
Multiturn | 12 Bit | |
Overall resolution | 25 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062 | |
Connection | ||
Cable | &empty11.2 mm, 9-core, 2 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | ||
Gas Ex-area | -40 ... 55 °C (-40 ... 131 °F) | |
Dust Ex-area | -30 ... 55 °C (-22 ... 131 °F) | |
Storage temperature | ||
Gas Ex-area | -40 ... 70 °C (-40 ... 158 °F) | |
Dust Ex-area | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Material | ||
Housing | aluminum | |
Flange | aluminum | |
Shaft | Stainless steel | |
Mass | approx. 3400 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 400 gcm2 | |
Starting torque | &le 5 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ZELM 02 ATEX 0078 X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2012 EN 60079-1:2007 EN 60079-31:2009 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1400 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 300 mm | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 3 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 70 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Power consumption | max. 2.5 W | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 IP66, IP67 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-30 , no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 600 g (combination 1) approx. 1200 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 70 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Current consumption | max. 230 mA at 10 V DC, max. 100 mA at 24 V DC | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, shaft side: IP64 (without shaft seal)/IP66 (with shaft seal) housing side: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -30 ... 55 °C (-22 ... 131 °F) | |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Mass | approx. 600 g (combination 1) | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2012 , EN 60079-15:2010 , EN 60079-31:2009 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 37 a | |
Mission Time (TM) | 20 a | |
L10 | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Cable | &empty9.6 mm, 7-core | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Marking | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | PNP | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1300 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 3 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Multiturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 37 a | |
Mission Time (TM) | 20 a | |
L10 | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 1000 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFIBUS | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 0.0096 ... 12 MBit/s | |
Standard conformity | PNO profile 3.062, RS-485 | |
Connection | ||
Cable | &empty9.6 mm, 7-core | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: Stainless steel 1.4305 / AISI 303 flange: Stainless steel 1.4305 / AISI 303 shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ITS 15 ATEX 18371X IECEx ITS 11.0060X | |
Marking | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Pulse count | 1024 | |
Functional safety related parameters | ||
MTTFd | 140 a | |
Mission Time (TM) | 20 a | |
L10h | 2 E+9 | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 60 mA | |
Output | ||
Output type | push-pull, incremental | |
Voltage drop | < 4.4 V | |
Load current | max. per channel 40 mA , short-circuit prtected (not with Ub), reverse polarity protected | |
Output frequency | max. 200 kHz | |
Rise time | 400 ns | |
Connection | ||
Connector | type 9416 (M23), 12-pin | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP66, IP68 | |
Climatic testing | ||
Static climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
Cyclic climatic testing | DIN EN 60068-2-30 55 °C, 6 cycles | |
Salt spray test | DIN EN 60068-2-52 , 672 h | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Material | ||
Housing | aluminum, coated, salt water resistant | |
Flange | aluminum, coated, salt water resistant | |
Shaft | stainless steel 1.4404 / AISI 316L | |
Mass | approx. 280 g | |
Rotational speed | max. 100 min -1 | |
Moment of inertia | &le 35 gcm2 | |
Starting torque | &le 4.5 Ncm | |
Shaft load | ||
Angle offset | 1 ° | |
Axial offset | max. 1 mm |
General specifications | ||
---|---|---|
Pulse count | 1024 and 2048 | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Performance level (PL) | PL e | |
MTTFd | 1000 a | |
Mission Time (TM) | 20 a | |
PFHd | 2.41 E-9 | |
L10h | 7.5 E+9 at 6000 rpm | |
Diagnostic Coverage (DC) | 98 % | |
Electrical specifications | ||
Operating voltage | 5 V DC ± 5 % | |
No-load supply current | max. 70 mA | |
Output | ||
Output type | sine / cosine | |
Amplitude | 1 Vss ± 10 % | |
Load current | max. per channel 10 mA , short-circuit protected, reverse polarity protected | |
Output frequency | max. 200 kHz (3 dB limit) | |
Connection | ||
Cable | Single stranded wires with crimp contact, 10 x AWG26, 230 mm | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP40 | |
Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
Noise immunity | DIN EN 61000-6-2 , advanced testing level to IEC 61326-3-1 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 55 ... 2000 Hz | |
Functional safety | IEC 61508:2000 IEC 62061:2005 ISO 13849-1:2006 IEC 61800-5-2:2007 EN 50178:1997 IEC 61326-3-1:2007 Suitable up to SIL 3, PL e depending from configuration, see manual and report | |
Approvals and certificates | ||
UL approval | cULus Recognized, General Purpose, Class 2 Power Source | |
TÜV approval | Cert. No. Z10 08 10 68273 001 | |
Ambient conditions | ||
Operating temperature | -20 ... 115 °C (-4 ... 239 °F) , fixed cable | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Material | ||
Housing | aluminum, blank | |
Flange | 3.1645 aluminum | |
Shaft | Stainless steel 1.4305 / AISI 303 | |
Mass | approx. 350 g | |
Rotational speed | max. 8000 min -1 | |
Moment of inertia | &le 25 gcm2 | |
Starting torque | &le 1.5 Ncm | |
Shaft load | ||
Axial | at 40 N max. 6000 rpm at 10 N max. 8000 rpm | |
Radial | at 60 N max. 6000 rpm at 20 N max. 8000 rpm |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NPN | |
Rated operating distance | 0.6 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 0.486 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.29 | |
Reduction factor r304 | 0.76 | |
Reduction factor rBrass | 0.46 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1400 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.055 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PC | |
Housing diameter | 4 mm | |
Degree of protection | IP67 |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.