| Описание оборудования | ||
|---|---|---|
| Safety control unit module | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit module | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit module | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with 1 optional module slot for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with 1 optional module slot for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| SB4 series safety control unit with optional module slots for functional enhancement | ||
| Описание оборудования | ||
|---|---|---|
| Self-monitored safety relay module | ||
| Описание оборудования | ||
|---|---|---|
| Empty housing for Evaluation unit SB4 | ||
| Описание оборудования | ||
|---|---|---|
| Safety control unit from the PSE2/PSE4 series | ||
| System components | ||
|---|---|---|
| Emitter | SLC-2-T | |
| Receiver | SLC-2-R | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 500 mm | |
| Number of beams | 2 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP each, max. 100 mA for start readiness and OSSD status | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 | |
| System components | ||
|---|---|---|
| Emitter | SLC-2-T/92 | |
| Receiver | SLC-2-R/129/151 | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 500 mm | |
| Number of beams | 2 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP, max. 100 mA for start readiness | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin | |
| System components | ||
|---|---|---|
| Emitter | SLC-2-T/92 | |
| Receiver | SLC-2-R/151 | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 500 mm | |
| Number of beams | 2 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP, max. 100 mA for start readiness | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin | |
| System components | ||
|---|---|---|
| Emitter | SLC-2-T | |
| Receiver | SLC-2-R/31 | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 500 mm | |
| Number of beams | 2 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 relay outputs, force-guided NO-contact | |
| Signal output | 1 PNP each, max. 100 mA for start readiness and OSSD status | |
| Switching voltage | 50 V | |
| Switching current | max. 2 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 | |
| System components | ||
|---|---|---|
| Emitter | SLC-3-T | |
| Receiver | SLC-3-R | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 400 mm | |
| Number of beams | 3 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP each, max. 100 mA for start readiness and OSSD status | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 | |
| System components | ||
|---|---|---|
| Emitter | SLC-3-T/92 | |
| Receiver | SLC-3-R/129/151 | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 400 mm | |
| Number of beams | 3 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP, max. 100 mA for start readiness | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin | |
| System components | ||
|---|---|---|
| Emitter | SLC-3-T/92 | |
| Receiver | SLC-3-R/151 | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 400 mm | |
| Number of beams | 3 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 separated fail safe semiconductor outputs | |
| Signal output | 1 PNP, max. 100 mA for start readiness | |
| Switching voltage | Operating voltage -2 V | |
| Switching current | max. 0.5 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin | |
| System components | ||
|---|---|---|
| Emitter | SLC-3-T | |
| Receiver | SLC-3-R/31 | |
| General specifications | ||
| Effective detection range | 0.2 ... 20 m | |
| Light source | IRED | |
| Light type | modulated infrared light | |
| Safety type according to IEC/EN 61496 | 4 | |
| Target size | 50 mm | |
| Beam spacing | 400 mm | |
| Number of beams | 3 | |
| Operating mode | can be selected with or without start/restart disable | |
| Angle of divergence | < 5 ° | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Category | Cat. 4 | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.27 E-9 | |
| Indicators/operating means | ||
| Diagnostics indicator | 7-segment display in receiver | |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready | |
| Pre-fault indicator | LED orange | |
| Electrical specifications | ||
| Operating voltage | 24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %) | |
| Input | ||
| Function input | Start release | |
| Output | ||
| Safety output | 2 relay outputs, force-guided NO-contact | |
| Signal output | 1 PNP each, max. 100 mA for start readiness and OSSD status | |
| Switching voltage | 50 V | |
| Switching current | max. 2 A | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 | |
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.