Каталожный номер: 114863
System components
EmitterSLP10-3-T
ReceiverSLPCM10-3-R/31
General specifications
Effective detection range0.2 ... 10 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114872
System components
EmitterSLP10-4-T
ReceiverSLPCM10-4-R
General specifications
Effective detection range0.2 ... 10 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114876
System components
EmitterSLP10-4-T
ReceiverSLPCM10-4-R-L
General specifications
Effective detection range0.2 ... 10 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114868
System components
EmitterSLP10-4-T
ReceiverSLPCM10-4-R-L/31
General specifications
Effective detection range0.2 ... 10 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114864
System components
EmitterSLP10-4-T
ReceiverSLPCM10-4-R/31
General specifications
Effective detection range0.2 ... 10 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114884
System components
EmitterSLP30-2-T
ReceiverSLPCM30-2-R
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114887
System components
EmitterSLP30-2-T
ReceiverSLPCM30-2-R-L
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114881
System components
EmitterSLP30-2-T
ReceiverSLPCM30-2-R-L/31
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114878
System components
EmitterSLP30-2-T
ReceiverSLPCM30-2-R/31
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114885
System components
EmitterSLP30-3-T
ReceiverSLPCM30-3-R
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114888
System components
EmitterSLP30-3-T
ReceiverSLPCM30-3-R-L
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114882
System components
EmitterSLP30-3-T
ReceiverSLPCM30-3-R-L/31
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114879
System components
EmitterSLP30-3-T
ReceiverSLPCM30-3-R/31
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114886
System components
EmitterSLP30-4-T
ReceiverSLPCM30-4-R
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114889
System components
EmitterSLP30-4-T
ReceiverSLPCM30-4-R-L
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114883
System components
EmitterSLP30-4-T
ReceiverSLPCM30-4-R-L/31
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114880
System components
EmitterSLP30-4-T
ReceiverSLPCM30-4-R/31
General specifications
Effective detection range6 ... 30 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114896
System components
EmitterSLP65-2-T
ReceiverSLPCM65-2-R
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114899
System components
EmitterSLP65-2-T
ReceiverSLPCM65-2-R-L
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114893
System components
EmitterSLP65-2-T
ReceiverSLPCM65-2-R-L/31
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114890
System components
EmitterSLP65-2-T
ReceiverSLPCM65-2-R/31
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114897
System components
EmitterSLP65-3-T
ReceiverSLPCM65-3-R
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114900
System components
EmitterSLP65-3-T
ReceiverSLPCM65-3-R-L
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114894
System components
EmitterSLP65-3-T
ReceiverSLPCM65-3-R-L/31
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114891
System components
EmitterSLP65-3-T
ReceiverSLPCM65-3-R/31
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing400 mm
Number of beams3
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114898
System components
EmitterSLP65-4-T
ReceiverSLPCM65-4-R
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114901
System components
EmitterSLP65-4-T
ReceiverSLPCM65-4-R-L
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114895
System components
EmitterSLP65-4-T
ReceiverSLPCM65-4-R-L/31
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage terminals,
M12 connector for transmitters, muting lamp, etc., muting sensors,
lamp socket for muting lamp, etc.
Узнать цену
Каталожный номер: 114892
System components
EmitterSLP65-4-T
ReceiverSLPCM65-4-R/31
General specifications
Effective detection range12 ... 65 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing300 mm
Number of beams4
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
B10dsee instruction manuals
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 relay outputs, force-guided NO-contact
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltage20 ... 60 V DC, 12 ... 25 V AC rms
Switching current0.01 ... 2 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену
Каталожный номер: 114873
System components
TransceiverSLPCM8-2-A
Mirror pillarSLP8-2-M
General specifications
Effective detection range0.2 ... 8 m
Light sourceLED
Light typemodulated visible red light
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Operating modeStart/restart disable, relay monitor, muting operating modes
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd3.54 E-9
Indicators/operating means
Diagnostics indicator7-segment display
Function indicatorLED red: per receiver channel
off: interruption
flashes: receiver
continuously on: reception with sufficient stability control
on the front plate: LED red: OSSD off
LED green: OSSD on
LED yellow: types of muting operation
Pre-fault indicatorLED red next to receiver flashes
Electrical specifications
Operating voltage24 V DC -15% / +25% , galvanically isolated
Input
Function inputRelay monitor, start release, muting sensors (max. 4)
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp
Switching voltageOperating voltage -2 V
Switching currentmax. 0.5 A
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment with cage-terminals,
M12-connector for emitter, muting lamp as well as other muting sensors
Узнать цену

Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите

Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.

Ключевые преимущества Pepperl+Fuchs

  • Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
  • Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
  • Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
  • Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
  • Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
  • Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.

Продуктовые направления

  • Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
  • Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
  • Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
  • Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
  • Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.

Области применения

Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.

Почему это выгодно

  • Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
  • Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
  • Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
  • Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
  • Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.

Как выбрать решение Pepperl+Fuchs

Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.

Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.

ООО "Зипстор"
127282, RU, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru