| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.75 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| Описание оборудования | ||
|---|---|---|
| Ultrasonic direct detection sensor | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 1/2"-20 UN , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 7/8 inch-16 UN , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| Описание оборудования | ||
|---|---|---|
| Twin-head system | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 10 m | |
| Cable version | PA | |
| Core cross-section | 0.75 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 1/2"-20 UN , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 7/8 inch-16 UN , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.4 | |
| Nominal ratings | ||
| Installation conditions | ||
| B | 25 mm | |
| C | 16 mm | |
| F | 37 mm | |
| Operating voltage | 15 ... 30 V | |
| Switching frequency | 0 ... 300 Hz | |
| Hysteresis | 0.05 ... 2.2 mm | |
| Reverse polarity protection | yes | |
| Short-circuit protection | no | |
| Overload resistance | no | |
| Wire breakage protection | yes | |
| Inductive overvoltage protection | yes | |
| Surge suppression | yes | |
| Ripple | 10 % | |
| Voltage drop | &le 8 V | |
| Repeat accuracy | 0.3 mm | |
| Operating current | 2 ... 25 mA | |
| Lowest operating current | 2 mA | |
| No-load supply current | &le 1.5 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.25 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Mass | 145 g | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1050 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1050 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Sensing range | 60 ... 500 mm | |
| Adjustment range | 60 ... 500 mm | |
| Dead band | 0 ... 60 mm | |
| Standard target plate | 10 mm x 10 mm | |
| Transducer frequency | approx. 300 kHz | |
| Indicators/operating means | ||
| LED green | Power on | |
| LED yellow 1 | solid: switching state switch output 1 flashing: misadjustment | |
| LED yellow 2 | solid: switching state switch output 2 flashing: misadjustment | |
| Electrical specifications | ||
| Operating voltage | 12 ... 30 V (including ripple) In supply voltage interval 12 ... 20 V sensitivity reduced to 20% ... 0% | |
| No-load supply current | &le 60 mA | |
| Input | ||
| Input type | 1 program input Teach-In of Smin | |
| Pulse length | &ge 150 ms | |
| Output | ||
| Output type | 2 switch outputs PNP, NO | |
| Rated operating current | 150 mA , short-circuit/overload protected | |
| Default setting | Switching distance "full", Smax: 80 mm Switching distance "empty", Smin: 450 mm Switching hysteresis "full", HSmax: 20 mm Switching hysteresis "empty", HSmin: 100 mm average value "full", MSmax: 20 average value "empty", MSmin: 110 | |
| Voltage drop | &le 3 V | |
| Switch-on delay | 80 ms | |
| Repeat accuracy | ± 0.45 mm | |
| Temperature influence | &le ± 1.5 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 5-pin | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PBT | |
| Transducer | epoxy resin/hollow glass sphere mixture polyurethane foam | |
| Mass | 500 g | |
| Описание оборудования | ||
|---|---|---|
| Single head system | ||
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Sensing range | 20 ... 60 mm , optimal distance: 45 mm | |
| Transducer frequency | 395 kHz | |
| Indicators/operating means | ||
| LED green | indication: single sheet detected | |
| LED yellow | Indication: No sheet detected (Air) | |
| LED red | indication: double sheet detected | |
| Electrical specifications | ||
| Operating voltage | 18 ... 30 V DC , ripple 10 %SS | |
| No-load supply current | < 80 mA | |
| Input | ||
| Input type | Function input 0-level: -UB ... -UB + 1V 1-level: +UB - 1 V ... +UB | |
| Pulse length | &ge 100 ms | |
| Impedance | &ge 4 k&Omega | |
| Output | ||
| Output type | 3 switch outputs PNP, NC | |
| Rated operating current | 3 x 100 mA , short-circuit/overload protected | |
| Voltage drop | &le 2 V | |
| Switch-on delay | approx. 1.5 ms | |
| Switch-off delay | approx. 1.5 ms | |
| Pulse extension | min. 120 ms programmable | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 60 °C (32 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | nickel plated brass plastic components: PBT | |
| Transducer | epoxy resin/hollow glass sphere mixture polyurethane foam | |
| Mass | 150 g | |
| General specifications | ||
|---|---|---|
| Sensing range | 20 ... 60 mm , optimal distance: 45 mm | |
| Transducer frequency | 255 kHz | |
| Indicators/operating means | ||
| LED green | Display: readiness | |
| LED yellow | Display: splice detected | |
| LED red | Indication: No sheet detected (Air) | |
| Electrical specifications | ||
| Operating voltage | 18 ... 30 V DC , ripple 10 %SS | |
| No-load supply current | < 60 mA | |
| Input | ||
| Input type | Teach-In input 0-level: -UB ... -UB + 1V 1-level: +UB - 1 V ... +UB | |
| Pulse length | &ge 500 ms | |
| Impedance | &ge 10 k&Omega | |
| Output | ||
| Output type | 2 switch outputs PNP, NC | |
| Rated operating current | 2 x 100 mA , short-circuit/overload protected | |
| Voltage drop | &le 3 V | |
| Switch-on delay | &le 600 µs | |
| Switch-off delay | &le 600 µs | |
| Pulse extension | &ge 120 ms programmable | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 60 °C (32 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M12 x 1 , 5-pin with PVC Cable, 150 mm | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | nickel plated brass plastic components: PBT | |
| Transducer | epoxy resin/hollow glass sphere mixture polyurethane foam | |
| Mass | 150 g | |
| Cable length | l1 = 0.3 m l2 = 0.15 m | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Sensing range | 20 ... 60 mm , optimal distance: 45 mm | |
| Transducer frequency | 255 kHz | |
| Indicators/operating means | ||
| LED green | Display: readiness | |
| LED yellow | Display: splice detected | |
| LED red | Indication: No sheet detected (Air) | |
| Electrical specifications | ||
| Operating voltage | 18 ... 30 V DC , ripple 10 %SS | |
| No-load supply current | < 60 mA | |
| Input | ||
| Input type | Teach-In input 0-level: -UB ... -UB + 1V 1-level: +UB - 1 V ... +UB | |
| Pulse length | &ge 500 ms | |
| Impedance | &ge 10 k&Omega | |
| Output | ||
| Output type | 2 switch outputs PNP, NC | |
| Rated operating current | 2 x 100 mA , short-circuit/overload protected | |
| Voltage drop | &le 3 V | |
| Switch-on delay | &le 600 µs | |
| Switch-off delay | &le 600 µs | |
| Pulse extension | &ge 120 ms programmable | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 60 °C (32 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP67 | |
| Connection | 2 m PVC cable 0.14 mm2 | |
| Material | ||
| Housing | nickel plated brass plastic components: PBT | |
| Transducer | epoxy resin/hollow glass sphere mixture polyurethane foam | |
| Mass | 150 g | |
| Mechanical specifications | ||
|---|---|---|
| Material | black PVC | |
| Cable | Li Y 11Y 3 x 0.14 | |
| Color | black | |
| Mass | 20 g | |
| Cable length | 1 m | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 7.6 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Mechanical specifications | ||
|---|---|---|
| Connection | 9-pin Sub-D socket | |
| Material | ||
| Cable | PUR | |
| Cable | ||
| Color | black | |
| Cable length | 3 m | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm typ. 10 mm | |
| Reduction factor rAl | 0.36 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.67 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 1 ... 10 typ. 6 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.8 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1881 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PMMA | |
| Sensing face | PMMA | |
| Degree of protection | IP67 | |
| Описание оборудования | ||
|---|---|---|
| Programming adapter | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm typ. 10 mm | |
| Reduction factor rAl | 0.36 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.67 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 1 ... 10 typ. 6 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.8 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1881 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PMMA | |
| Sensing face | PMMA | |
| Degree of protection | IP67 | |
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 170 a | |
| Mission Time (TM) | 20 a | |
| L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 180 mA | |
| Linearity | ± 0.5 LSB (12 Bit) | |
| Output code | Gray code | |
| Code course (counting direction) | cw descending (clockwise rotation, code course descending) | |
| Interface | ||
| Interface type | SSI | |
| Monoflop time | 20 ± 10 µs | |
| Resolution | ||
| Single turn | 12 Bit | |
| Overall resolution | 12 Bit | |
| Transfer rate | 0.1 ... 2 MBit/s | |
| Voltage drop | UB - 2.5 V | |
| Standard conformity | RS 422 | |
| Input 1 | ||
| Input type | Selection of counting direction (cw/ccw) | |
| Signal voltage | ||
| High | 10 ... 30 V | |
| Low | 0 ... 2 V | |
| Input current | < 6 mA | |
| Switch-on delay | < 0.001 ms | |
| Connection | ||
| Connector | 8-pin, M12 x 1 connector | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
| Mass | approx. 460 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | 50 gcm2 | |
| Starting torque | < 5 Ncm | |
| Shaft load | ||
| Axial | 40 N | |
| Radial | 110 N | |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.