Каталожный номер: 45028
| Описание оборудования |
|---|
| Synchro clamping element |
Каталожный номер: 240277
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 17 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 990 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR black , 25 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 45018
| Описание оборудования |
|---|
| Spring steel coupling |
Каталожный номер: 806489
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 17 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 990 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR black , 3 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 103947
| Описание оборудования |
|---|
| Female connector |
Каталожный номер: 85321
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Constant magnetic field | 200 mT |
| Alternating magnetic field | 200 mT |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 990 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Brass, PTFE coated |
| Sensing face | PPS |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 191139
| General specifications |
|---|
| Switching element function | Analog current output with PNP binary NO |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm |
| Measurement range | 0 ... 120 mm |
| Linearity range | 1 ... 119 mm |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
| Repeat accuracy | ± 0.1 mm |
| Resolution | 125 µm |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED green |
| Functional safety related parameters |
|---|
| MTTFd | 270 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Switching output |
|---|
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
| Operating current | &le 100 mA |
| Switching window | ± 1 mm |
| Switching hysteresis | 0.4 mm |
| Voltage drop | &le 3 V |
| Short-circuit protection | pulsing |
| Analog output |
|---|
| Output type | 1 current output: 4 ... 20 mA |
| Load resistor | &le 400 &Omega |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 5-pin, M12 x 1 connector |
| Degree of protection | IP67 |
| Material | |
| Housing | ABS |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Каталожный номер: 191136
| General specifications |
|---|
| Switching element function | analog, current or voltage output |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm |
| Measurement range | 0 ... 120 mm |
| Linearity range | 1 ... 119 mm |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
| Repeat accuracy | ± 0.1 mm |
| Resolution | 125 µm |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED green |
| Analog output |
|---|
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega |
| Short-circuit protection | voltage output: pulsing |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 4-pin, M12 x 1 connector |
| Degree of protection | IP67 |
| Material | |
| Housing | ABS |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Каталожный номер: 910206
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | Multihole-LED, yellow |
| Mag. Field strength, AC fields | 200 mT |
| Mag. Field strength, DC fields | 200 mT |
| Functional safety related parameters |
|---|
| MTTFd | 2430 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Brass, PTFE coated |
| Sensing face | Ceramic coated |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 191138
| General specifications |
|---|
| Switching element function | Analog current output with PNP binary NO |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm |
| Measurement range | 0 ... 104 mm |
| Linearity range | 1 ... 103 mm |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
| Repeat accuracy | ± 0.1 mm |
| Resolution | 125 µm |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED green |
| Functional safety related parameters |
|---|
| MTTFd | 280 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Switching output |
|---|
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
| Operating current | &le 100 mA |
| Switching window | ± 1 mm |
| Switching hysteresis | 0.4 mm |
| Voltage drop | &le 3 V |
| Short-circuit protection | pulsing |
| Analog output |
|---|
| Output type | 1 current output: 4 ... 20 mA |
| Load resistor | &le 400 &Omega |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 5-pin, M12 x 1 connector |
| Degree of protection | IP67 |
| Material | |
| Housing | ABS |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Каталожный номер: 191141
| General specifications |
|---|
| Switching element function | analog, current or voltage output |
| Object distance | max. 6 mm |
| Measurement range | 0 ... 360 mm |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | ± 0.4 mm |
| Repeat accuracy | ± 0.2 mm |
| Resolution | 360 µm |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED green |
| Functional safety related parameters |
|---|
| MTTFd | 210 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Analog output |
|---|
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega |
| Short-circuit protection | voltage output: pulsing |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 4-pin, M12 x 1 connector |
| Housing length L | 400 mm |
| Degree of protection | IP65 |
| Material | |
| Housing | PA 6 / AL |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. |
Каталожный номер: 236481
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
| Reduction factor rAl | 0.35 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.4 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 65 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 0.02 ... 0.44 |
| Reverse polarity protection | yes |
| Short-circuit protection | yes |
| Overload resistance | yes |
| Wire breakage protection | yes |
| Inductive overvoltage protection | yes |
| Surge suppression | yes |
| Ripple | 10 % |
| Voltage drop | &le 2.5 V |
| Repeat accuracy | 0.1 mm |
| Operating current | 0 ... 300 mA |
| Off-state current | 0.01 mA |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1510 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | 4-pin, M12 x 1 connector |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| Mass | 20 g |
Каталожный номер: 199092
| General specifications |
|---|
| Installation | non-flush |
| Measurement range | 360° |
| Rotational speed | max. 100 min-1 |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V |
| Reverse polarity protection | reverse polarity protected |
| Repeat accuracy | ± 0.25 ° |
| Resolution | 0.4° |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) |
| No-load supply current | &le 45 mA |
| Operating voltage indicator | LED green |
| Functional safety related parameters |
|---|
| MTTFd | 265 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Switching output |
|---|
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
| Operating current | &le 100 mA |
| Voltage drop | &le 3 V |
| Short-circuit protection | pulsing |
| Analog output |
|---|
| Output type | 1 current output: 4 ... 20 mA |
| Linearity error | ± 0.6 ° , (with original actuator) |
| Load resistor | &le 400 &Omega |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | 5-pin, M12 x 1 connector |
| Housing material | PBT |
| Shaft diameter | max. 27.5 mm Steel |
| Degree of protection | IP67 |
| Mass | 180 g |
Каталожный номер: 89923
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 17 mA |
| Switching state indicator | Multihole-LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 4-pin, M12 x 1 connector |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 215314
| General specifications |
|---|
| Adjustment range | 3 switch frames programmable , min. 5°, max. 360° |
| Rotational speed | max. 100 min-1 |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Repeat accuracy | ± 0.25 ° |
| Resolution | 0.2 ° |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) |
| No-load supply current | &le 45 mA |
| Functional safety related parameters |
|---|
| MTTFd | 450 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Indicators/operating means |
|---|
| LED yellow 1 | switching state, Switching output 1 |
| LED yellow 2 | switching state, Switching output 2 |
| LED yellow 3 | switching state, Switching output 3 |
| LED PWR/ERR | Status display LED, green/red (Power on / missing actuator / keylock) |
| Switching output |
|---|
| Output type | 3 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable |
| Operating current | &le 100 mA |
| Switching hysteresis | 1 ° |
| Voltage drop | &le 3 V |
| Short-circuit protection | pulsing |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 5-pin, M12 x 1 connector |
| Degree of protection | IP67 |
| Material | |
| Housing | PBT |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Mass | 180 g |
Каталожный номер: 205697
| General specifications |
|---|
| Switching element function | analog, current or voltage output |
| Object distance | max. 6 mm |
| Measurement range | 0 ... 510 mm |
| Nominal ratings |
|---|
| Operating voltage | 18 ... 30 V DC |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | ± 0.6 mm |
| Repeat accuracy | ± 0.5 mm |
| Resolution | 550 µm |
| Temperature drift | ± 0.7 mm (-25 °C ... 70 °C) |
| No-load supply current | &le 65 mA |
| Operating voltage indicator | LED green |
| Functional safety related parameters |
|---|
| MTTFd | 165 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Analog output |
|---|
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega |
| Short-circuit protection | voltage output: pulsing |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | 4-pin, M12 x 1 connector |
| Housing length L | 550 mm |
| Degree of protection | IP65 |
| Material | |
| Housing | PA 6 / AL |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. |
Каталожный номер: 199290-0025
| Описание оборудования |
|---|
| Reading head, SSI interface, binary code |
Каталожный номер: 87771
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 17 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 990 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 202964
| Описание оборудования |
|---|
| WCS Profibus interface module |
Каталожный номер: 87772
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 17 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 990 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 305274
| Описание оборудования |
|---|
| Transparent protective case and seal for WCS3B reader |
Каталожный номер: 83761
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.66 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 20 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 3220 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 229390
| Описание оборудования |
|---|
| USB cable unit with power supply |
Каталожный номер: 84007
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.66 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 3220 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 251412
| Описание оборудования |
|---|
| Read head for incident light positioning system |
Каталожный номер: 83762
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.66 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 20 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 3220 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 259676
| Описание оборудования |
|---|
| Read head for incident light positioning system |
Каталожный номер: 84008
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.66 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 3220 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: T157523
| Описание оборудования |
|---|
| Data Matrix code tape |
Каталожный номер: 236478
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
| Reduction factor rAl | 0.35 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.4 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 65 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 0.02 ... 0.44 |
| Reverse polarity protection | yes |
| Short-circuit protection | yes |
| Overload resistance | yes |
| Wire breakage protection | yes |
| Inductive overvoltage protection | yes |
| Surge suppression | yes |
| Ripple | 10 % |
| Voltage drop | &le 2.5 V |
| Repeat accuracy | 0.1 mm |
| Operating current | 0 ... 300 mA |
| Off-state current | 0.01 mA |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1510 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.25 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Mass | 75 g |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.