Electrical specifications | ||
---|---|---|
Nominal voltage | 7.2 V | |
Nominal current | 250 mA | |
Nominal capacity | 19 Ah , capacity can varies with usage conditions | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Storage temperature | 15 ... 30 °C (59 ... 86 °F) recommended -40 ... 80 °C (-40 ... 176 °F) at accelerated derating | |
Mechanical specifications | ||
Mass | approx. 285 g | |
Dimensions | 75 x 71 x 39 mm (2.95 x 2.8 x 1.5 inch) |
Описание оборудования | ||
---|---|---|
Coaxial cable, N plug to N plug |
General specifications | ||
---|---|---|
Equipment architecture | switching element: changeover switching on point: 15 mbar ± 3 mbar, switching off point: 9 mbar ± 3 mbar max. hydrostatic pressure: 500 mbar | |
Supply | ||
Rated voltage | 253 V AC , 50/60 Hz | |
Current consumption | max. 1 A | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Operating conditions | ||
Process conditions | ||
Process temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP54 | |
Connection | flat plug 6.3 x 0.8 mm (0.25 x 0.03 inch), DIN 46244 | |
Material | housing: PA pipe: stainless steel 1.4571/316Ti or PVC | |
Dimensions | housing: 100 x 75 x 80 mm (4 x 3 x 3.1 inch) pipe: length L 180 ... 5000 mm (0.6 ... 16.5 ft) | |
Process connection | thread G1/2 to ISO 228 |
Supply | ||
---|---|---|
Rated voltage | 8.2 V ± 2 V | |
Current consumption | < 1.0 mA unswitched (de-energized at the bottom), > 2.2 mA switched (floated up at the top) | |
Reverse polarity protection | yes | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 60947-5-2:2007+A1:2012 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | Proximity switch with operation ball | |
Function and system design | ||
Equipment architecture | A measuring system consists of a float switch LFL1-**-N and a transformer isolated barrier, e. g. KFD2-SR2-Ex1.W. | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland &ge G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. | |
Process conditions | ||
Process pressure (static pressure) | sleeve design: &le 3 bar at 20 °C (68 °F) ball design: &le 2 bar at 20 °C (68 °F) | |
Density | sleeve design: &ge 0.8 g/cm3 ball design: &ge 0.6 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Altitude | &le 2000 m above MSL | |
Mechanical specifications | ||
Degree of protection | IP68 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | TÜV 99 ATEX 1407 | |
Group, category, type of protection | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
Mechanical construction | ||
Material | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (2 x 0.75 mm2) - PUR version: PUR cable, highly flexible (2 x 0.50 mm2) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (2 x 0.75 mm2)) |
Electrical specifications | ||
---|---|---|
Contact loading | 250 V AC/3 A 150 V DC/0.25 A resistive load 60 V DC/1 A resistive load | |
Rated insulation voltage | 300 V | |
Pulse withstand voltage | 4 kV | |
Directive conformity | ||
Low voltage | ||
Directive 2014/35/EU | EN 60947-5-1:2004 + Cor.:2005 + A1:2009 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | microswitch with switching ball, change-over contact | |
Function and system design | ||
Equipment architecture | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland &ge G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. | |
Process conditions | ||
Process pressure (static pressure) | sleeve design: &le 3 bar at 20 °C (68 °F) ball design: &le 2 bar at 20 °C (68 °F) | |
Density | sleeve design: &ge 0.8 g/cm3 ball design: &ge 0.6 g/cm3 | |
Ambient conditions | ||
Ambient temperature | PVC version: 5 ... 70 °C (41 ... 158 °F) PUR version: 5 ... 70 °C (41 ... 158 °F) CSM/CM version: -20 ... 70 °C (-4 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Altitude | &le 2000 m above MSL | |
Mechanical specifications | ||
Degree of protection | IP68 | |
Mechanical construction | ||
Material | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (3 x 0.75 mm2) - PUR version: PUR cable, highly flexible (3 x 0.50 mm2) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (3 x 0.75 mm2)) |
Electrical specifications | ||
---|---|---|
Contact loading | 230 V AC/3 A/200 VA 150 V DC/3 A/100 W resistive load | |
Rated insulation voltage | 300 V | |
Pulse withstand voltage | 4 kV | |
Directive conformity | ||
Low voltage | ||
Directive 2014/35/EU | EN 60947-5-1:2004 + Cor.:2005 + A1:2009 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | mercury (Hg) change-over contact | |
Function and system design | ||
Equipment architecture | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes - TPK version: &ge 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland &ge G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. | |
Process conditions | ||
Process pressure (static pressure) | sleeve design: &le 3 bar at 20 °C (68 °F) ball design: &le 2 bar at 20 °C (68 °F) | |
Density | sleeve design: &ge 0.8 g/cm3 ball design: &ge 0.6 g/cm3 | |
Ambient conditions | ||
Ambient temperature | PVC version: 5 ... 70 °C (41 ... 158 °F) PUR version: 5 ... 70 °C (41 ... 158 °F) CSM/CM version: -20 ... 70 °C (-4 ... 158 °F) TPK version: 5 ... 70 °C (41 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Altitude | &le 2000 m above MSL | |
Mechanical specifications | ||
Degree of protection | IP68 | |
Mechanical construction | ||
Material | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (3 x 0.75 mm2) - PUR version: PUR cable, highly flexible (3 x 0.50 mm2) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (3 x 0.75 mm2)) - TPK version: TPK cable, (3 x 0.75 mm2) |
Supply | ||
---|---|---|
Rated voltage | see datasheets of float switches | |
Electrical specifications | ||
Contact loading | see datasheets of float switches | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | see datasheets of float switches | |
Low voltage | ||
Directive 2014/35/EU | see datasheets of float switches | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Application | ||
Description | switching element: LFL1: floating up closing, normally open LFL2: microswitch with switching ball, change-over contact LFL3: mercury (Hg) change-over contact | |
Operating conditions | ||
Installation conditions | ||
Installation instructions | range of application and minimum length between mounting and float: - PVC version: &ge 50 mm (2 inch), preferred for water - PUR version: &ge 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: &ge 100 mm (4 inch), preferred for many acids and lyes Float switches are fastened onto the lower end of the guide pipe in the factory. The position of the switch points required for the application must be adjusted by the user by moving the set collars (in some cases, it may be necessary to shorten the float switch wire). | |
Process conditions | ||
Process pressure (static pressure) | &le 1 bar at 20 °C (68 °F) | |
Ambient conditions | ||
Ambient temperature | 5 ... 70 °C (41 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | Float Switch : IP68 terminal box: IP66 | |
Mechanical construction | ||
Dimensions | guide tube: &empty16 mm (0.6 inch), Lmax = 3000 mm (10 feet) | |
Material | float: PP (Polypropylene) guide tube: PVC process connection: PVC set collars and clamping screw: PVC |
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Equipment architecture | A measuring system consists of a rod electrode HR-6**1** with electrode relay KFA6-ER 1.6, KFD2-ER 1.6, KFD2-ER-Ex1.W.LB or KFA6-ER-Ex1.W.LB. | |
Input | ||
Measured variable | measuring voltage directly from the electrode relay | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Operating conditions | ||
Process conditions | ||
Process temperature | process connection 6: <= 150 °C (423 K) process connection 7: <= 90 °C (363 K) process connection 8: <= 150 °C (423 K) | |
Process pressure (static pressure) | process connection 6: &le 30 bar process connection 7: &le 16 bar process connection 8: &le 6 bar | |
Mechanical specifications | ||
Degree of protection | IP65 with terminal box IP52 with plug connector | |
Connection | terminals in plug connector or in terminal box plug connector: terminal, max. 1 mm2 terminal box: terminal, max. 2.5 mm2 | |
Material | housing: stainless steel 1.4571/316Ti, PP or PTFE process connection: stainless steel 1.4571/316Ti, PP or PTFE electrode rod: stainless steel 1.4571/316Ti, Hastelloy C, titanium or tantalum | |
Dimensions | housing: max. Ø43 mm (1.7 inch), height max. 55 mm (2.2 inch) rod: length L max. 3000 mm (10 foot) | |
Process connection | thread G1/2 to ISO 228 |
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Equipment architecture | A measuring system consists of a rod electrode HR-6*5*** with electrode relay KFA6-ER 1.6, KFD2-ER 1.6, KFD2-ER-Ex1.W.LB or KFA6-ER-Ex1.W.LB. | |
Input | ||
Measured variable | measuring voltage directly from the electrode relay | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Operating conditions | ||
Process conditions | ||
Process temperature | process connection 6: <= 150 °C (423 K) process connection 7: <= 90 °C (363 K) process connection 8: <= 150 °C (423 K) | |
Process pressure (static pressure) | process connection 6: <= 40 bar process connection 7: <= 10 bar process connection 8: <= 6 bar | |
Mechanical specifications | ||
Degree of protection | IP65 with terminal box | |
Connection | terminals in the terminal box: connection, max. 2.5 mm2 | |
Material | housing: stainless steel 1.4571/316Ti, PP or PTFE process connection: stainless steel 1.4571/316Ti, PP or PTFE electrode rod: stainless steel 1.4571/316Ti, Hastelloy C, titanium or tantalum | |
Dimensions | housing: max. Ø65 mm (2.6 inch), height max. 75 mm (3 inch) rods: length L1 ... L5 max. 3000 mm (10 foot) | |
Process connection | thread G1-1/4A to DIN/ISO 228/1 | |
Accessories | ||
Designation | - spacer, PTFE for Ø4 mm (0.16 inch) rods - spacer with clamp screw, PTFE, for Ø4 mm (0.16 inch) rods - spacer with clamp screw, PTFE, for Ø6 mm (0.24 inch) rods - counter nut G1-1/4A made of PVC - counter nut G1-1/4A made of stainless steel - LZ-1201, mounting angle of stainless steel 1.4571/316Ti with drilling for G1/2A - LZ-1203, mounting angle of stainless steel 1.4571/316Ti with drilling for G1-1/4A |
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Input | ||
Measured variable | Measuring voltage from the switch amplifier via converter | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Operating conditions | ||
Process conditions | ||
Process temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Process pressure (static pressure) | process connection 6: &le 30 bar process connection 7: &le 16 bar process connection 8: &le 6 bar | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) use thermal protection tube for medium temperatures between +60 ... +150 ° C | |
Mechanical specifications | ||
Degree of protection | IP65 with terminal box | |
Connection | electrodes - converter: connection to the converter via connector plug in the terminal box converter - switch amplifier: terminals in the terminal box below the converter | |
Material | housing: PBT process connection: stainless steel 1.4571/316Ti, PP or PTFE electrode rod: stainless steel 1.4571/316Ti, Hastelloy C, titanium or tantalum | |
Dimensions | housing: max. Ø65 mm (2.6 inch), height max. 75 mm (3 inch) rods: length L max. 3000 mm (10 foot) | |
Process connection | thread G1-1/4A to DIN/ISO 228/1 | |
Certificates and approvals | ||
Overspill protection | Z-65.13-6 (overspill protection in acc. with WHG) | |
Accessories | ||
Designation | - spacer, PTFE for Ø4 mm (0.16 inch) rods - spacer with clamp screw, PTFE, for Ø4 mm (0.16 inch) rods - spacer with clamp screw, PTFE, for Ø6 mm (0.24 inch) rods - counter nut G1-1/4A made of PVC - counter nut G1-1/4A made of stainless steel - LZ-1201, mounting angle of stainless steel 1.4571/316Ti with drilling for G1/2A - LZ-1203, mounting angle of stainless steel 1.4571/316Ti with drilling for G1-1/4A - electronical converter HR-011420 |
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Input | ||
Measured variable | Measuring voltage from the switch amplifier via converter | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Operating conditions | ||
Process conditions | ||
Process temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Process pressure (static pressure) | &le 30 bar | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 with terminal box | |
Connection | electrodes - converter: connection to the converter via connector plug in the terminal box converter - switch amplifier: terminals in the terminal box below the converter | |
Material | housing: PBT process connection: stainless steel 1.4571/316Ti electrode rod: stainless steel 1.4571/316Ti, Hastelloy C or tantalum | |
Dimensions | housing: max. Ø65 mm (2.6 inch), height max. 75 mm (3 inch) rods: length L max. 3000 mm (10 foot) | |
Process connection | thread G1-1/4A to DIN/ISO 228/1 | |
Data for application in connection with hazardous areas | ||
Certificate of Compliance | PTB Nr. Ex-88.B:2003 | |
Group, category, type of protection | ![]() | |
Certificates and approvals | ||
Overspill protection | 01/PTB Nr.: Ex-79/2011X (overspill protection acc. to VbF) | |
Accessories | ||
Designation | - spacer, PTFE for Ø4 mm (0.16 inch) rods - spacer with clamp screw, PTFE, for Ø4 mm (0.16 inch) rods - spacer with clamp screw, PTFE, for Ø6 mm (0.24 inch) rods - counter nut G1-1/4A made of PVC - counter nut G1-1/4A made of stainless steel - LZ-1201, mounting angle of stainless steel 1.4571/316Ti with drilling for G1/2A - LZ-1203, mounting angle of stainless steel 1.4571/316Ti with drilling for G1-1/4A - electronical converter HR-011420 |
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Equipment architecture | A measuring system consists of a suspension electrode HR-690121 with electrode relay KFA6-ER 1.6, KFD2-ER 1.6, KFD2-ER-Ex1.W.LB or KFA6-ER-Ex1.W.LB. | |
Versions | HR-690121/05, suspension electrode, 5 m (5.5 yd) cable, PVC HR-690121/10, suspension electrode, 10 m (11 yd) cable, PVC HR-690121/20, suspension electrode, 20 m (22 yd) cable, PVC | |
Input | ||
Measured variable | measuring voltage directly from the electrode relay | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Operating conditions | ||
Process conditions | ||
Process temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Material | thread, cable insulation and electrode: PVC electrode tip: stainless steel 1.4571/316Ti | |
Dimensions | electrode: Ø20 mm (0.8 inch), length 160 mm (6.3 inch) cable: length max. 20 m (21.9 yard) |
Описание оборудования | ||
---|---|---|
230 V AC |
General specifications | ||
---|---|---|
Function principle | ring magnet as switching element in the float, reed contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts switching function: - version DO: with rising level NC contact - version DS: with rising leve NO contact - version DW: with rising level change-over contact | |
Equipment architecture | A measuring system consists of a magnet-operated immersion probe LML*S*-**S-**-Ex and a (up to 3) isolated amplifier(s) with certified intrinsically safe circuit, for example KFD2-SR2-Ex1.W. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
Conformity | ||
Degree of protection | IEC 60529:2000 | |
Operating conditions | ||
Process conditions | ||
Process temperature | -30 ... 150 °C (-22 ... 302 °F) | |
Process pressure (static pressure) | &le 25 bar (362.6 psi) | |
Density | version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
Ambient conditions | ||
Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | max. 6 terminals, max. 2.5 mm2 | |
Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
Dimensions | float: - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | KEMA 03 ATEX 1496 X | |
Group, category, type of protection, temperature class | ![]() | |
Voltage | 36 V | |
Current | 100 mA | |
Internal capacitance | 0 nF | |
Internal inductance | 0 µH | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
Accessories | ||
Optional accessories | LML-Z11 set collar, 1.4571/316Ti LML-FS2 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti LML-FS3 float, ball, Ø52 mm, 1.4571/316Ti |
General specifications | ||
---|---|---|
Function principle | ring magnet as switching element in the float, reed contact, change-over contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts | |
Supply | ||
Rated voltage | 250 V AC/DC | |
Current consumption | 1 A | |
Output | ||
Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
Directive conformity | ||
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2000 | |
Operating conditions | ||
Process conditions | ||
Process temperature | version PP: -10 ... 80 °C (14 ... 176 °F) version PVDF: -10 ... 100 °C (14 ... 212 °F) | |
Process pressure (static pressure) | &le 3 bar (43.5 psi) | |
Density | &ge 0.8 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | version LML: terminal box, max. 9 terminals version LML-PVC1: connection cable 1 m (3.3 ft), 0.75 mm2 | |
Material | float, guide tube, process connection: - version PP: PP (Polypropylene) - version PVDF: PVDF (Polyvinylidenfluoride) connection cable: PVC terminal box: Polyester | |
Dimensions | float: - version PP: cylinder &empty44 mm x 44 mm - version PVDF: cylinder &empty55 mm x 70 mm guide tube: - version D: &empty12 mm, max. length 1000 mm - version P: &empty16 mm, max. length 1000 mm terminal box: 80 x 82 x 55 mm | |
Process connection | thread G3/8A, G1-1/2A, G2A to DIN/ISO 228/1 | |
Accessories | ||
Optional accessories | LML-Z21 set collar, PP LML-Z22 set collar, PVDF LML-FD5 float, cylinder, Ø55 mm x 70 mm, PVDF LML-FP7 float, cylinder, Ø44 mm x 44 mm, PP |
General specifications | ||
---|---|---|
Function principle | ring magnet as switching element in the float, reed contact, change-over contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts | |
Supply | ||
Rated voltage | 250 V AC/DC | |
Current consumption | 1 A | |
Output | ||
Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
Directive conformity | ||
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2000 | |
Operating conditions | ||
Process conditions | ||
Process temperature | version LML: -30 ... 150 °C (-22 ... 302 °F) version LML-PVC1: -10 ... 80 °C (14 ... 176 °F) | |
Process pressure (static pressure) | &le 25 bar (362.6 psi) | |
Density | version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | version LML: terminal box, max. 9 terminals version LML-PVC1: connection cable 1 m (3.3 ft), 0.75 mm2 | |
Material | float, guide tube, process connection: stainless steel 1.4571/316Ti connection cable: PVC terminal box: aluminum die-casting | |
Dimensions | float: - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm | |
Process connection | thread G3/8A, G1-1/2A, G2A to DIN/ISO 228/1 | |
Accessories | ||
Optional accessories | LML-Z11 set collar, 1.4571/316Ti LML-FS2 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti LML-FS3 float, ball, Ø52 mm, 1.4571/316Ti |
General specifications | ||
---|---|---|
Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-G6*-O4 and a potentiometer converter KFD2-PT2-Ex1. | |
Versions | LMC10P6-G6P-O4 LMC10D5-G6D-O4 | |
Output | ||
Connection | 3-wire, potentiometer connection approx. 40 k&Omega | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
Conformity | ||
Degree of protection | IEC 60529:2000 | |
Measurement accuracy | ||
Accuracy | resolution: 10 mm | |
Operating conditions | ||
Process conditions | ||
Process temperature | version PP: -10 ... 80 °C (14 ... 176 °F) version PVDF: -10 ... 100 °C (14 ... 212 °F) | |
Process pressure (static pressure) | &le 3 bar (43.5 psi) | |
Density | &ge 0.8 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 3 terminals, max. 2.5 mm2 | |
Material | float, guide tube, process connection: - version PP: PP (Polypropylene) - version PVDF: PVDF (Polyvinylidenfluoride) terminal box: Polyester | |
Dimensions | float: - version PP: cylinder &empty55 mm x 54 mm - version PVDF: cylinder &empty55 mm x 70 mm guide tube: &empty14 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm | |
Process connection | thread G2A to DIN/ISO 228/1 | |
Accessories | ||
Optional accessories | LML-FD5 float, cylinder, Ø55 mm x 70 mm, PVDF LML-FP6 float, cylinder, Ø55 mm x 54 mm, PP |
General specifications | ||
---|---|---|
Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I with built-in converter and a transmitter power supply KFD2-STC4-1 or of a magnet-operated immersion probe LMC****-***-O4 and a potentiometer converter KFD2-PT2-Ex1. | |
Output | ||
Connection | version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 k&Omega | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
Conformity | ||
Degree of protection | IEC 60529:2000 | |
Measurement accuracy | ||
Accuracy | resolution: - version LMC5: 5 mm - version LMC15: 15 mm | |
Operating conditions | ||
Process conditions | ||
Process temperature | -20 ... 120 °C (-4 ... 248 °F) | |
Process pressure (static pressure) | &le 16 bar (232.1 psi) | |
Density | version S1: &ge 0.6 g/cm3 version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 | |
Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
Dimensions | float: - version S1: ball &empty80 mm - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: - version LMC5: &empty14 mm, max. length 3000 mm - version LMC15: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm | |
Process connection | thread G1/2A, G1-1/2A to DIN/ISO 228/1 | |
Accessories | ||
Optional accessories | LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, polypropylene | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | G1½A connection |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, stainless steel 1.4571 | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | G1½A connection |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, polypropylene | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | screwed connection 1½" NPT |
General specifications | ||
---|---|---|
Sensing range | 0.3 ... 4 m , with fluids | |
Transducer frequency | approx. 85 kHz | |
Indicators/operating means | ||
LED green | Power on | |
LED red | 2 Hz flashing: error | |
Electrical specifications | ||
Operating voltage | 20 ... 30 V DC , ripple 10 %SS | |
Power consumption | &le 1200 mW | |
Output | ||
Output type | 1 analog output 4 ... 20 mA, RL &le 500 Ohm, error &ge 21 mA 1 voltage output 0 ... 10 V, RL &ge 1000 Ohm, error &ge 10.5 V | |
Resolution | 2 mm | |
Deviation of the characteristic curve | 0.5 % of upper limit of measuring range | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Connection | 5-pin V15 (M12 x 1) connector | |
Material | ||
Housing | PBT, stainless steel 1.4571 | |
Transducer | PTFE (diaphragm surface) | |
Mass | 220 g | |
Mounting | screwed connection 1½" NPT |
Описание оборудования | ||
---|---|---|
230 V AC |
Описание оборудования | ||
---|---|---|
230 V AC |
Описание оборудования | ||
---|---|---|
230 V AC |
Описание оборудования | ||
---|---|---|
230 V AC |
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | Power Rail or terminals 11+, 12- | |
Rated voltage | 20 ... 30 V DC | |
Input | ||
Connection side | field side | |
Connection | terminals 1 (mass), 2 (min), 3 (max) | |
Open circuit voltage/short-circuit current | approx. 10 V AC (approx. 1 Hz) / approx. 5 mA | |
Control input | min./max. control system: terminals 1, 2, 3 on/off control system: terminals 1, 3 | |
Response sensitivity | 5 ... 150 k&Omega , adjustable via potentiometer (20 turns) | |
Output | ||
Connection side | control side | |
Connection | terminals 7, 8, 9 | |
Output | 1 changeover contact | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Energized/De-energized delay | approx. 1 s / approx. 1 s | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch potentiometer | |
Configuration | via DIP switches via potentiometer | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals , max. 2.5 mm2 | |
Mass | approx. 110 g | |
Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Описание оборудования | ||
---|---|---|
24 V DC |
Описание оборудования | ||
---|---|---|
24 V DC |
Описание оборудования | ||
---|---|---|
24 V DC |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.