Описание оборудования | ||
---|---|---|
6000 Series intrinsically safe cable harness |
Описание оборудования | ||
---|---|---|
6000 Series intrinsically safe cable harness |
Описание оборудования | ||
---|---|---|
6000 Series intrinsically safe cable harness |
Ambient conditions | ||
---|---|---|
Ambient temperature | -60 ... 200 °C (-76 ... 392 °F) | |
Mechanical specifications | ||
Degree of protection | IP64 | |
Material | brass, nickel-plated | |
Dimensions | 40 mm long x 32 mm across the flats | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | Sira 10ATEX1225X Sira 00ATEX1073U IECEx SIR 09.084U GOST TC C-GB.06.B00105 INMETRO NCC 12.0764U | |
Group, category, type of protection | Exd I&IIc / Exe I&II / Ex tD A21 |
Ambient conditions | ||
---|---|---|
Ambient temperature | -60 ... 200 °C (-76 ... 392 °F) | |
Mechanical specifications | ||
Degree of protection | IP64 | |
Material | brass, nickel-plated | |
Dimensions | 40 mm long x 32 mm across the flats | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | Sira 10ATEX1225X Sira 00ATEX1073U IECEx SIR 09.084U GOST TC C-GB.06.B00105 INMETRO NCC 12.0764U | |
Group, category, type of protection | Exd I&IIc / Exe I&II / Ex tD A21 |
Electrical specifications | ||
---|---|---|
Connection | Shield / ground: capacitively coupled to ground | |
Mechanical specifications | ||
Connection type | Screw Terminals Field devices: 0.13 - 2.08 mm² max (26 - 14 AWG) Torque 5-7 in-lb (0.6 to 0.8 Nm) Screw Terminals EPCU: 0.08 - 1.31 mm² (28 - 16 AWG) Torque 4 in-lb (0.5 Nm) | |
Degree of protection | IP20 | |
Terminal assembly | ||
Terminal type | Field connection | |
Terminal capacity | Min: 24 AWG (0.2 mm2) Max: 12 AWG (3.3 mm2) | |
Mass | 800 g | |
Dimensions | 83 x 126 x 67 mm (3.3" x 5.0" 2.6") | |
Mounting | DIN rail mounting , 2 mounting clips | |
General information | ||
System information | Must be used with 6000 series purge system to meet certification requirements. |
Описание оборудования | ||
---|---|---|
Temperature Hub for 6000 Series Purge system |
Описание оборудования | ||
---|---|---|
Temperature Sensor for 6000 Series Purge system |
Описание оборудования | ||
---|---|---|
Pressure relief vent |
General specifications | ||
---|---|---|
Operating mode | automatic purging | |
Hazardous environment | gas or dust | |
Supply | ||
Rated power | 24 VDC: 5.6 W 120 VAC: 7.2 VA, 60 Hz 230 VAC: 7.2 VA, 60 Hz Voltage tolerance: +/-10% | |
Electrical specifications | ||
Fuse rating | DC: 500 mA AC: 80 mA (fuse rating on 5500 control unit) | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 1.4 bar (20 psi) to 8.2 bar (120 psi) | |
Purge flow rate | solenoid valve : Cv (flow coefficient) = 1.4 needle valve : Cv (flow coefficient) = 0.24 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Mechanical specifications | ||
Connection type | Pneumatic Input port: 3/8" Tube compression fitting Output port: 3/8" Tube compression fitting Electrical connection ½" NPTF thread connection w/ 24" (0.61m) flying leads | |
Degree of protection | type 7 & 9 | |
Material | Housing: anodized aluminum 3/8" compression fittings: 316 stainless steel Pressure ports: 3/8" NPTF Bulkhead fitting: 316 stainless steel Mounting bolts: 1/4 - 20, 316 stainless steel Sealing washers: UL recognized type 4X | |
Mass | 1250 g (2.8 lb) | |
Dimensions | see dimensions | |
International approvals | ||
UL approval | ||
cULus | Class I Division 2, Group A-D Class II Division 2, Group F+G | |
CSA approval | Class I Division 2, Group A-D Class II Division 2, Group F+G |
General specifications | ||
---|---|---|
Operating mode | automatic purging | |
Hazardous environment | gas or dust | |
Supply | ||
Rated power | 24 VDC: 4.6 W 120 VAC: 6.8 VA, 60 Hz 230 VAC: 6.8 VA, 60 Hz Voltage tolerance: +/-10% | |
Electrical specifications | ||
Fuse rating | DC: 500 mA AC: 80 mA (fuse rating on 5500 control unit) | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 1.4 bar (20 psi) to 8.2 bar (120 psi) | |
Purge flow rate | solenoid valve : Cv (flow coefficient) = 1.4 needle valve : Cv (flow coefficient) = 0.25 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Connection type | Pneumatic Input port: 3/8" Tube compression fitting Output port: 3/8" Tube compression fitting Electrical connection ½" NPTF thread connection w/ 24" (0.61m) flying leads | |
Degree of protection | type 7 & 9 | |
Material | Housing: anodized aluminum 3/8" compression fittings: 316 stainless steel Pressure ports: 3/8" NPTF Bulkhead fitting: 316 stainless steel Mounting bolts: 1/4 - 20, 316 stainless steel Sealing washers: UL recognized type 4X | |
Mass | 1250 g (2.8 lb) | |
Dimensions | see dimensions | |
International approvals | ||
FM approval | FM3006713 Explosion proof: Class I, Divison 1, Group A-D, T4, Ta = 60C DIP: Class II, Division 1, Groups F+G, T4, Ta = 60C Nonincendive: Class I, Division 2, Groups A-D, T4, Ta = 60C Suitable for Class II, Division 2, Groups F+G, T4, Ta = 60C | |
CSA approval | CSA 202633 Class I, Division 1, Groups A-D: Class II, Groups E,F,G Class I, Division 2, Groups A-D |
General specifications | ||
---|---|---|
Operating mode | automatic purging | |
Hazardous environment | gas or dust | |
Supply | ||
Rated power | 24 VDC: 2.6 W 3.1 VA, 50...60 Hz 3.0 VA, 50...60 Hz Voltage tolerance: +/-10% | |
Electrical specifications | ||
Fuse rating | DC: 500 mA AC: 80 mA (fuse rating on 5500 control unit) | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 1.7 bar (25 psi) to 8.0 bar (115 psi) | |
Purge flow rate | solenoid valve : Cv (flow coefficient) = 1.4 needle valve : Cv (flow coefficient) = 0.25 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) T5 | |
Mechanical specifications | ||
Connection type | Pneumatic Input port: 3/8" Tube compression fitting Output port: 3/8" Tube compression fitting | |
Degree of protection | type 7 & 9 | |
Material | Housing: anodized aluminum 3/8" compression fittings: 316 stainless steel Pressure ports: 3/8" NPTF Bulkhead fitting: 316 stainless steel Mounting bolts: 1/4 - 20, 316 stainless steel Sealing washers: UL recognized type 4X | |
Cable | 3 m | |
Mass | 1250 g (2.8 lb) | |
Dimensions | see dimensions | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() ![]() Protection by encapsulation PTB 03 ATEX 2018 X | |
International approvals | ||
IECEx approval | ![]() ![]() Protection by encapsulation IECEx PTB 04.0002X |
General specifications | ||
---|---|---|
Hazardous environment | gas or dust | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Maximum pressure | depends on the integrity of the enclosure (strength) | |
Purge flow rate | See graphs | |
Flow rate for leakage compensation | EPV-5500....-01: approx. 21 scfh (593 l/hr) @ 0.25" w.c. (0.63 mbar) approx. 58 scfh (1640 l/hr) @ 0.75" w.c. (1.9 mbar) EPV-5500....-02: approx. 14 scfh (395 l/hr) @ 0.25" w.c. (0.63 mbar) approx. 34 scfh (961 l/hr) @ 0.75" w.c. (1.9 mbar) EPV-5500....-03: approx. 9.2 scfh (260 l/hr) @ 0.25" w.c. (0.63 mbar) approx. 22 scfh (622 l/hr) @ 0.75" w.c. (1.9 mbar) | |
Breaking pressure | EPV-5500....-01: 0.8" w.c. (2.0 mbar) EPV-5500....-02: 1.4" w.c. (3.5 mbar) EPV-5500....-03: 1.5" w.c. (3.8 mbar) | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | 5 ... 90 %, non-condensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Degree of protection | EPV-5500....-01/02: mounting only Type 4X EPV-5500....-03: Type 4X | |
Material | ||
Housing | EPV-5500-AA... body and cap: 6061T6 aluminum EPV-5500-SS... body: 6061T6 aluminum, cap: 316L stainless steel | |
Spark arrestor | 316L, (1.4404) stainless steel | |
Installation | - any orientation to enclosure - not gravity dependent - internal and external mounting possible | |
Mass | approx. 1005 g (2.2 lb) | |
Dimensions | see dimensions | |
Mounting | mounting hole 1 ½" NPT knockout (50.8mm) hole sealing nut (provided) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ATEX UL / DEMKO 14 ATEX 1282X | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006 | |
International approvals | ||
UL approval | RFPW, E184741, RFPW7, E184741 | |
IECEx approval | IECEx UL/DEMKO 14.0019X |
Описание оборудования | ||
---|---|---|
Ex pz purge system for Zone 2 and 22 |
Supply | ||
---|---|---|
Rated voltage | 230 VAC - 230 VAC ± 10 % 115 VAC - 115 VAC ± 10% 24 VDC - 24 VDC ± 10% | |
Power consumption | 230 VAC - 230 VAC @ 5 W 115 VAC - 115 VAC @ 6 W 24 VDC - 24 VDC @ 8 W | |
Ambient conditions | ||
Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Material | body: brass valve (internal): brass seal: NBR |
Ambient conditions | ||
---|---|---|
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Mechanical specifications | ||
Material | body: Grivory® (PA66) seal: NBR |
General specifications | ||
---|---|---|
Number of volume exchanges | min. 5 | |
Hazardous environment | gas or dust | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Maximum pressure | 25 mbar (10" H2O) | |
Safe pressure | - gas 0.25 mbar (0.1" H2O) (Zone 2) - dust 0.5 mbar (0.2" H2O) (Zone 22) | |
Purge flow and enclosure pressure rate | - for 3.0 mm orifice at 2 bar (29 psig): 105 l/min, 8 ... 10 mbar - for 4.5 mm orifice at 2 bar (29 psig): 220 l/min, 8 ... 10 mbar | |
Flow rate for leakage compensation | 0.3 l/min typ. (enclosure pressure at 1 mbar, depends on enclosure seal) | |
Breaking pressure | 3 mbar (1.2" H2O) | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | 5 ... 95 %, noncondensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Material | ||
Housing | polyester | |
Spark arrestor | Stainless steel (multi screen) | |
Installation | - any orientation to enclosure - not gravity dependent - internal and external mounting possible | |
Mass | approx. 320 g (0.7 lb) | |
Dimensions | 66 x 111 x 55 mm (2.6 x 4.4 x 2.2 inch) | |
Mounting | mounting hole 37 mm with locking ring | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | EPS 10 ATEX 1263 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection, temperature class | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006 |
Описание оборудования | ||
---|---|---|
Pressure relief vent for use with the Pepperl+Fuchs Bebco EPS® purge and pressurization systems |
Описание оборудования | ||
---|---|---|
3003 Series purge and pressurization system |
Описание оборудования | ||
---|---|---|
3004 Series purge and pressurization system |
Описание оборудования | ||
---|---|---|
Environmental purge for nonhazardous dusty/dirty areas |
Описание оборудования | ||
---|---|---|
Pressure relief vent for use with the Pepperl+Fuchs Bebco EPS® purge and pressurization systems |
Описание оборудования | ||
---|---|---|
Industrial Box Thin Client |
Описание оборудования | ||
---|---|---|
12 inch flat panel monitor for Class I, Div 2 Class II, Div 2 and Atex Zone 2 applications. |
Описание оборудования | ||
---|---|---|
15 inch flat panel monitor for Class I, Div 2 Class II, Div 2 and Atex Zone 2 applications. |
General specifications | ||
---|---|---|
Type | Remote Monitor | |
Supply | ||
Rated voltage | 24 V DC ( 20 ... 30 V DC ) | |
Power consumption | max. 75 W | |
Indicators/operating means | ||
Display | ||
Type | TFT, LCD | |
Screen diagonal | 48.3 cm (19 inch) | |
Resolution | 1280 x 1024 pixels representable: 640 x 480 up to 1280 x 1024 pixels | |
Color depth | 16 Mio. | |
Contrast | 1000:1 | |
Brightness | 300 cd/m2 | |
Reading angle | 89° / 89° / 89° / 89° | |
Life span | 50.000 h @ 25 °C | |
Input devices | Analog resistive touchscreen (optional) , Keyboard with integrated mouse functionality: touchpad/joystick versions available | |
Interface | ||
Interface type | USB , RS-485, RS-422, RS 232, Ethernet , TTY | |
Ambient conditions | ||
Operating temperature | -10 ... 50 °C (14 ... 122 °F) (at switching on) -20 ... 50 °C (-4 ... 122 °F) (when operating) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | max. 85 % non-condensing (48 h endurance test) | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Installation | Mountable on floor, wall or ceiling several mounting options (turnable/fix) available | |
Mass | approx. 41 kg | |
Dimensions | 537 x 457 x 158 mm (display) 590 x 700 x 470 mm (surface-mounted case) | |
Cut out dimensions | 466 mm x 389 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 07 ATEX E 008 X 2nd Edition | |
Group, category, type of protection | ![]() ![]() ![]() ![]() | |
International approvals | ||
IECEx approval | IECEx BVS 08.0030X |
Описание оборудования | ||
---|---|---|
19 inch flat panel monitor for Class I, Div 2 Class II, Div 2 and ATEX Zone 2 applications. |
Описание оборудования | ||
---|---|---|
Industrial monitor designed for continuous use in harsh environments |
Описание оборудования | ||
---|---|---|
Industrial monitor designed for continuous use in harsh environments |
Описание оборудования | ||
---|---|---|
Operator workstation designed for continuous use in harsh environments |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.