General specifications | ||
---|---|---|
Type | Keyboard with joystick | |
Suitable components | SK-PC-D2-UU1-10-HS | |
Supply | ||
Rated voltage | Ex i, via data line | |
Indicators/operating means | ||
Keyboard | 105 entry keys Keyboard layout: US international (further keyboard layouts on demand) | |
Joystick | ||
Driver | Microsoft Mouse ® , USB | |
Interface | ||
Interface type | USB | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61000-4-2: 2009, EN 61000-4-3: 2006 + A1: 2008, EN 61000-4-4: 2004, EN 61000-4-6: 2009, EN 55011: 2009, EN 61000-6-2: 2005, EN 61000-6-4: 2007, EN 61326-1: 2006 | |
Conformity | ||
Degree of protection | IP66 (front plate) Type 4X | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Relative humidity | max. 85 % , non-condensing (48 h endurance test) | |
Mechanical specifications | ||
Material | anodized aluminum , Polyester foil | |
Mass | 1.2 kg | |
Dimensions | Desktop mount: 559.3 mm x 254.6 mm x 44.5 mm (22.02" x 10.02" x 1.75") Panel mount: 491.4 mm x 186.8 mm x 45 mm (19.35" x 7.35" x 1.77") | |
Cut out dimensions | 483 mm x 178.2 mm | |
Cable length | 1.8 m | |
Data for application in connection with hazardous areas | ||
Certificate of conformity | PF II CERT 1918X | |
Group, category, type of protection | ![]() ![]() | |
Input | ||
Voltage | 5.4 V DC | |
Current | 240 mA | |
Power | 600 mW | |
Internal capacitance | 25 µF | |
Internal inductance | negligible | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0: 2009 EN 60079-11: 2007 | |
International approvals | ||
UL approval | cULus (E190294) | |
Approved for | Class I, Division 2, Groups A, B, C, D, T4 |
General specifications | ||
---|---|---|
No-load protection | yes | |
RoHs | conform | |
Supply | ||
Rated voltage | 100 ... 240 VAC +/- 10%, 50 - 60 Hz wide-range power supply | |
Output | ||
Output rated operating current | 0 ... 5 A, (7,5 A current limitation) | |
Output voltage | 24 V DC ± 3% over the entire input voltage range | |
Efficiency | 88 % (typ.) | |
Holdup time | > 50 ms over the entire input voltage range | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 55022 Class B, Line harminic distortion acc. to EN 61000-3-2, EN 61000-6-1/2 | |
Low voltage | EN60950 | |
Explosion protection | ||
Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Mass | approx. 40 kg | |
Dimensions | 459 mm x 301.5 mm x 226 mm | |
Dimensions with wall mount bracket | 489 mm x 412 mm x 255 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
Group, category, type of protection | ![]() ![]() | |
International approvals | ||
IECEx approval | IECEx BVS 08.0024 |
Supply | ||
---|---|---|
Rated voltage | 20 ... 28 V DC | |
Output | ||
Output voltage | rated voltage | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN55022 Class B, EN61000-6-1/-2 | |
Low voltage | EN60950 | |
Explosion protection | ||
Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Mass | approx. 40 kg | |
Dimensions | 459 mm x 301.5 mm x 226 mm | |
Dimensions with wall mount bracket | 489 mm x 412 mm x 255 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
Group, category, type of protection | ![]() ![]() | |
International approvals | ||
IECEx approval | IECEx BVS 08.0024 |
Описание оборудования | ||
---|---|---|
Industrial Ethernet Media Converter |
Описание оборудования | ||
---|---|---|
DC Power Supply |
Supply | ||
---|---|---|
Rated voltage | 20 ... 28 V DC | |
Output | ||
Output voltage | rated voltage | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN55022 Class B, EN61000-6-1/-2 | |
Low voltage | EN60950 | |
Explosion protection | ||
Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Mass | approx. 40 kg | |
Dimensions | 459 mm x 301.5 mm x 226 mm | |
Dimensions with wall mount bracket | 489 mm x 412 mm x 255 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
Group, category, type of protection | ![]() ![]() | |
International approvals | ||
IECEx approval | IECEx BVS 08.0024 |
General specifications | ||
---|---|---|
No-load protection | yes | |
RoHs | conform | |
Supply | ||
Rated voltage | 100 ... 240 VAC +/- 10%, 50 - 60 Hz wide-range power supply | |
Output | ||
Output rated operating current | 0 ... 5 A, (7,5 A current limitation) | |
Output voltage | 24 V DC ± 3% over the entire input voltage range | |
Efficiency | 88 % (typ.) | |
Holdup time | > 50 ms over the entire input voltage range | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 55022 Class B, Line harminic distortion acc. to EN 61000-3-2, EN 61000-6-1/2 | |
Low voltage | EN60950 | |
Explosion protection | ||
Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | 85 % , noncondensing | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Mass | approx. 16 kg | |
Dimensions | 452 mm x 191 mm x 110 mm | |
Dimensions with wall mount bracket | 469 mm x 223 mm x 144 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
Group, category, type of protection | ![]() ![]() | |
International approvals | ||
IECEx approval | IECEx BVS 08.0024 |
General specifications | ||
---|---|---|
No-load protection | yes | |
RoHs | conform | |
Supply | ||
Rated voltage | 100 ... 240 VAC +/- 10%, 50 - 60 Hz wide-range power supply | |
Output | ||
Output rated operating current | 0 ... 5 A, (7,5 A current limitation) | |
Output voltage | 24 V DC ± 3% over the entire input voltage range | |
Efficiency | 88 % (typ.) | |
Holdup time | > 50 ms over the entire input voltage range | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 55022 Class B, Line harminic distortion acc. to EN 61000-3-2, EN 61000-6-1/2 | |
Low voltage | EN60950 | |
Explosion protection | ||
Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Mass | approx. 40 kg | |
Dimensions | 459 mm x 301.5 mm x 226 mm | |
Dimensions with wall mount bracket | 489 mm x 412 mm x 255 mm | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
Group, category, type of protection | ![]() ![]() | |
International approvals | ||
IECEx approval | IECEx BVS 08.0024 |
Описание оборудования | ||
---|---|---|
AC Power Supply |
Описание оборудования | ||
---|---|---|
AC Power Supply |
Описание оборудования | ||
---|---|---|
DC Power Supply |
General specifications | ||
---|---|---|
Type | Power supply |
Описание оборудования | ||
---|---|---|
Raritan Dominion KVM Switch |
Описание оборудования | ||
---|---|---|
DVI to CAT5 KVM kit |
Описание оборудования | ||
---|---|---|
DVI to fiber KVM kit |
Описание оборудования | ||
---|---|---|
VGA to CAT5 KVM kit |
Electrical specifications | ||
---|---|---|
Operating voltage | 1100 V AC max. | |
Operating current | 350 A max. | |
Mechanical specifications | ||
Enclosure cover | fully detachable , concealed hinges | |
Cover fixing | see PDF data sheet | |
Degree of protection | IP66 | |
Cable entry | see PDF data sheet | |
Gland plate on face(s) | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Terminal assembly | ||
Rail orientation | see PDF data sheet | |
Number of rails | see PDF data sheet | |
Usable length per rail | see PDF data sheet | |
Terminal type | Standard see PDF data sheet, other terminal types optional | |
Number of terminals per rail | see PDF data sheet | |
Material | ||
Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
Gland plate | 3 mm 316L, (1.4404) stainless steel | |
Finish | electropolished | |
Seal | one piece closed cell neoprene , optional silicone | |
Mass | see PDF data sheet | |
Dimensions | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M10 internal/external brass grounding bolt through enclosure body | |
Ambient conditions | ||
Ambient temperature | -40 ... 40 °C (-40 ... 104 °F) , optional -50 ... 120 °C (-58 ... 248 °F) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 99 ATEX 3199 | |
Marking | see PDF data sheet | |
International approvals | ||
IECEx approval | IECEx SIR 06.0074 | |
INMETRO | TÜV 13.1665X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This terminal box will be delivered completely configured and assembled ready for use. For configuration details please contact customer service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Mechanical specifications | ||
---|---|---|
Height | 260 mm (A) | |
Width | 260 mm (B) | |
Depth | 165 mm (C) | |
Fixing holes distance, height | 185 mm (G) | |
Fixing holes distance, width | 310 mm (H) | |
max. external dimension with mounting brackets | 335 mm (K) | |
Enclosure cover | fully detachable , concealed hinges | |
Cover fixing | M6 stainless steel hexagon head screws | |
Fixing holes diameter | 11 mm (J) | |
Degree of protection | IP66 | |
Cable entry | cable glands as per specification | |
Defined entry area | see PDF data sheet | |
Cable gland quantity C/D | 4 x M20 | |
Material | ||
Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
Finish | electropolished | |
Seal | one piece closed cell neoprene , optional silicone | |
Mass | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 13 ATEX 3059X Baseefa14ATEX0368U (FO splice tray) | |
Marking | ![]() Ex op pr IIC T5 Gb | |
International approvals | ||
IECEx approval | IECEx SIR 13.0021 IECEx BAS 14.0169U (FO splice tray) | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 690 V AC max. | |
Operating current | 350 A max. | |
Mechanical specifications | ||
Enclosure cover | fully detachable | |
Cover fixing | see PDF data sheet | |
Degree of protection | IP66 / IP67 | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Terminal assembly | ||
Rail orientation | see PDF data sheet | |
Number of rails | see PDF data sheet | |
Usable length per rail | see PDF data sheet | |
Terminal type | Standard see PDF data sheet, other terminal types optional | |
Number of terminals per rail | see PDF data sheet | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Grounding plate | see PDF data sheet | |
Seal | silicone cord | |
Mass | see PDF data sheet | |
Dimensions | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | none as standard optional M6 internal/external ground bolt | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 99 ATEX 3200X | |
Marking | see PDF data sheet | |
International approvals | ||
IECEx approval | IECEx SIR 06.0106X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This terminal box will be delivered completely configured and assembled ready for use. For configuration details please contact customer service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 6.6 kV | |
Operating current | 650 A max | |
Number of busbars | 3, each with 2 x M10 thru-holes with terminal lugs suitable for 70mm2 cable | |
Mechanical specifications | ||
Height | 977 mm | |
Width | 677 mm | |
Depth | 300 mm | |
Enclosure cover | fully detachable | |
Safety | Padlockable hasp | |
Degree of protection | IP66 | |
Cable entry | thru-holes via gland plate | |
Gland plate on face(s) | A & B | |
Material | ||
Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
Gland plate | 3 mm 316L, (1.4404) stainless steel | |
Finish | electropolished | |
Seal | Silicone rubber, one piece | |
Mass | approx. 44 kg | |
Mounting | thru-holes Ø11 mm | |
Grounding | M10 internal/external brass grounding bolt | |
Ambient conditions | ||
Ambient temperature | -50 ... 55 °C (-58 ... 131 °F) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | SIRA 00 ATEX 3206 | |
Group, category, type of protection, temperature class | ![]() | |
International approvals | ||
IECEx approval | IECEx SIR 06.0109 | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 690 V AC max. | |
Operating current | 109 A max. | |
Mechanical specifications | ||
Enclosure cover | fully detachable | |
Cover fixing | see PDF data sheet | |
Degree of protection | IP66 | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Terminal assembly | ||
Rail orientation | see PDF data sheet | |
Number of rails | see PDF data sheet | |
Usable length per rail | see PDF data sheet | |
Terminal type | Standard see PDF data sheet, other terminal types optional | |
Number of terminals per rail | see PDF data sheet | |
Material | ||
Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
Finish | electropolished | |
Seal | one piece closed cell neoprene | |
Mass | see PDF data sheet | |
Dimensions | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 internal/external brass grounding bolt | |
Ambient conditions | ||
Ambient temperature | -40 ... 40 °C (-40 ... 104 °F) , optional -50 ... 120 °C (-58 ... 248 °F) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 99 ATEX 3199 | |
Marking | see PDF data sheet | |
International approvals | ||
IECEx approval | IECEx SIR 06.0074 | |
INMETRO | TÜV 13.1665X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Terminal Junction Box will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 1100 V AC max. | |
Operating current | 350 A max. | |
Mechanical specifications | ||
Enclosure cover | fully detachable , exposed hinges | |
Cover fixing | see PDF data sheet | |
Degree of protection | IP66 | |
Cable entry | see PDF data sheet | |
Gland plate on face(s) | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Terminal assembly | ||
Rail orientation | see PDF data sheet | |
Number of rails | see PDF data sheet | |
Usable length per rail | see PDF data sheet | |
Terminal type | Standard see PDF data sheet, other terminal types optional | |
Number of terminals per rail | see PDF data sheet | |
Material | ||
Enclosure | 1.5 mm 316L, (1.4404) stainless steel | |
Gland plate | 3 mm 316L, (1.4404) stainless steel | |
Finish | electropolished | |
Seal | one piece closed cell neoprene | |
Mass | see PDF data sheet | |
Dimensions | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M10 internal/external brass grounding bolt through enclosure body | |
Ambient conditions | ||
Ambient temperature | -40 ... 40 °C (-40 ... 104 °F) , optional -50 ... 120 °C (-58 ... 248 °F) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 99 ATEX 3199 | |
Marking | see PDF data sheet | |
International approvals | ||
IECEx approval | IECEx SIR 06.0074 | |
INMETRO | TÜV 13.1665X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Terminal Junction Box will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66/67 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66/67 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Glass | thermo-resistant tempered glass | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Описание оборудования | ||
---|---|---|
Ex e control unit, stainless steel, 1x green LED indicator, with LED module |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.