Каталожный номер: 240162
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 7 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 5.67 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Inductive overvoltage protection | yes |
| Surge suppression | yes |
| Voltage drop | &le 2 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 6 µA at 25 °C |
| No-load supply current | &le 7 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1006 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 19 g |
Каталожный номер: 240159
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 7 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 5.67 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Inductive overvoltage protection | yes |
| Surge suppression | yes |
| Voltage drop | &le 2 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 7 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1006 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 3 x 0.75 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 120 g |
Каталожный номер: 240163
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 7 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 5.67 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Inductive overvoltage protection | yes |
| Surge suppression | yes |
| Voltage drop | &le 2 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 7 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1006 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 19 g |
Каталожный номер: 293453-0007
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | &ge 2000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 1.8 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1723 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Mass | 71 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293453-0008
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | &ge 2000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 1.8 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1723 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Mass | 15 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293453-0005
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | &ge 2000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 1.8 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1723 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Mass | 71 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293453-0006
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | &ge 2000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 1.8 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1723 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Mass | 15 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 187652
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| Switching state indicator | all direction LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1702 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0042
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 70 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 187653
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1702 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0060
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 18 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0043
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 70 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0061
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 18 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 88240
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.45 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 16 mA |
| Switching state indicator | all direction LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1702 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 88241
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.45 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 16 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1702 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0056
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP68 / IP69K |
| Mass | 18 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0039
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 70 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 225165
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.39 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.45 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 16 mA |
| Switching state indicator | all direction LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Cable connector M8 x 1 , PVC , 200 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 293454-0040
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 70 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0058
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP68 / IP69K |
| Mass | 18 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0041
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP68 / IP69K |
| Mass | 70 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 293454-0059
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 24 mm x 24 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 7 ... 30 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1484 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| E1 Type approval | 10R-04 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP68 / IP69K |
| Mass | 18 g |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 281565
| General specifications |
|---|
| Output type | Digital current output |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 9 ... 30 V DC |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | 2 ... 15 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Temperature drift | &le 10 % |
| Load resistor | 100 ... 250 Ohm |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1601 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Digital output |
|---|
| Output type | object detected: 10 mA ± 1 mA object not detected: 5 mA ± 1 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 3 x 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP68 / IP69K |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 281566
| General specifications |
|---|
| Output type | Digital current output |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 9 ... 30 V DC |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | 2 ... 15 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Temperature drift | &le 10 % |
| Load resistor | 100 ... 250 Ohm |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1601 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Digital output |
|---|
| Output type | object detected: 10 mA ± 1 mA object not detected: 5 mA ± 1 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP68 / IP69K |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 197869
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | AC/DC |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 20 ... 250 V AC/20 ... 300 V DC |
| Switching frequency | 30 Hz |
| Hysteresis | 3 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | yes |
| Voltage drop | &le 8 V |
| Operating current | 8 ... 200 mA AC/DC |
| Off-state current | &le 0.8 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector 1/2"-20 UN , 3-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 197870
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | AC/DC |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 20 ... 250 V AC/20 ... 300 V DC |
| Switching frequency | 30 Hz |
| Hysteresis | 3 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | yes |
| Voltage drop | &le 8 V |
| Operating current | 8 ... 200 mA AC/DC |
| Off-state current | &le 0.8 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Scope of delivery | 2 self locking nuts in scope of delivery |
Каталожный номер: 806948
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 25 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 4 x 0.34 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP69K |
Каталожный номер: 237200
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 25 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 10 m |
| Core cross-section | 4 x 0.34 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP69K |
Каталожный номер: 88857
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 25 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 15 m |
| Core cross-section | 4 x 0.34 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP69K |
Каталожный номер: 86349
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP68 / IP69K |
| Note | use only delivered nuts |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.