Запчасти и компоненты для торгового оборудования. Более 8 500 клиентов и более 1 000 000 товаров! Скрыть

Тип запчасти - Адаптер

Сортировать по: Название   Цена   Блоки Таблица
Каталожный номер: AT-WNP300N
Узнать цену
Каталожный номер: EBXA-USB-WIFI
Розничная цена
117 $ с НДС 11116 с НДС
В корзину
Купить в 1 клик
Каталожный номер: T159381
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Connectable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.1, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialaluminum
Massapprox. 1000 g
Dimensions91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
versions see type code
Data for application in connection with hazardous areas
EC-Type Examination CertificateBVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection, temperature classEx-Hexagon II 2 G Ex ia IIC T4 Gb
Ex-Hexagon II 2 D Ex tb [ia] IIIC T70°C Db IP6x
Directive conformity
Directive 94/9/ECEN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009
International approvals
IECEx approvalBVS 11.0061
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-MKF8
Узнать цену
Каталожный номер: T46566
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Connectable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.1, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
versions see type code
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-MKF8
Узнать цену
Каталожный номер: T155586
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Connectable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.1, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
versions see type code
Data for application in connection with hazardous areas
EC-Type Examination CertificateBVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection, temperature classEx-Hexagon II 2 G Ex ia IIC T4 Gb
Directive conformity
Directive 94/9/ECEN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009
International approvals
IECEx approvalBVS 11.0061
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-MKF8
Узнать цену
Каталожный номер: 261308
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
MaterialAluminum
Massapprox. 1000 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 17 ATEX E 029
MarkingEx-Hexagon II 2G Ex ia IIC T4/T3 Gb
Ex-Hexagon II 2D Ex tb [ia] IIIC T70°C Db
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
CSA approval
Control drawing116-0435
IECEx approval
IECEx certificateIECEX BVS 17.0023
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Каталожный номер: 261305
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Каталожный номер: 261306
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 17 ATEX E 029
MarkingEx-Hexagon II 2G Ex ia IIC T4/T3 Gb
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approval
IECEx certificateIECEX BVS 17.0023
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Каталожный номер: T0058764712
Розничная цена
94 $ с НДС 8931 с НДС
В корзину
Купить в 1 клик
Каталожный номер: 41908
Розничная цена
27 $ с НДС 2566 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3CI-FF
Розничная цена
24 $ с НДС 2238 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3CI-MF
Розничная цена
29 $ с НДС 2744 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3MX3-FM
Розничная цена
29 $ с НДС 2796 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3MX3-MM
Розничная цена
32 $ с НДС 3077 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3X3-FF
Розничная цена
29 $ с НДС 2796 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3X3-FM
Розничная цена
26 $ с НДС 2514 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3X3-MM
Розничная цена
27 $ с НДС 2591 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3X5-FM
Розничная цена
29 $ с НДС 2796 с НДС
В корзину
Купить в 1 клик
Каталожный номер: HI-X3X5-MF
Розничная цена
29 $ с НДС 2796 с НДС
В корзину
Купить в 1 клик
Розничная цена
56 $ с НДС 5313 с НДС
В корзину
Купить в 1 клик
Розничная цена
50 $ с НДС 4755 с НДС
В корзину
Купить в 1 клик
Каталожный номер: CN-000803-05
Розничная цена
12 $ с НДС 1141 с НДС
В корзину
Купить в 1 клик
Каталожный номер: ADP-RFD40-EC5X-1E
Розничная цена
6 $ с НДС 523 с НДС
В корзину
Купить в 1 клик
Каталожный номер: ADP-RFD40-EC5X-1E
Розничная цена
6 $ с НДС 523 с НДС
В корзину
Купить в 1 клик
Каталожный номер: ADP-MC32-CUP0-01
Розничная цена
60 $ с НДС 5679 с НДС
В корзину
Купить в 1 клик
Каталожный номер: ADP-MC32-CUP0-04
Основные характеристики Напряжение на входе: 220 В Дополнительные характеристики Цвет: Черный Вес брутто: 500 г
Розничная цена
239 $ с НДС 22713 с НДС
В корзину
Купить в 1 клик
Каталожный номер: ADP-MC93-CRDCUP-01
Розничная цена
13 $ с НДС 1236 с НДС
В корзину
Купить в 1 клик
Каталожный номер: CHG-AUTO-USB1-01
Розничная цена
20 $ с НДС 1901 с НДС
В корзину
Купить в 1 клик
Розничная цена
994 $ с НДС 94433 с НДС
В корзину
Купить в 1 клик
Розничная цена
1 182 $ с НДС 112294 с НДС
В корзину
Купить в 1 клик
ООО "Зипстор"
127282, RU, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru