| General specifications |
|---|
| Sensing range | 30 ... 250 mm |
| Adjustment range | 50 ... 250 mm |
| Dead band | 0 ... 30 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 310 kHz |
| Response delay | approx. 50 ms |
| Electrical specifications |
|---|
| Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
| No-load supply current | &le 30 mA |
| Input |
|---|
| Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 k&Omega, pulse duration: &ge 1 s |
| Output |
|---|
| Output type | 1 switch output PNP Normally open/closed , programmable |
| Rated operating current | 100 mA , short-circuit/overload protected |
| Default setting | Switch point A1: 50 mm Switch point A2: 250 mm |
| Voltage drop | &le 3 V |
| Repeat accuracy | &le 1 % |
| Switching frequency | &le 8 Hz |
| Range hysteresis | 1 % of the set operating distance |
| Temperature influence | ± 1.5 % of full-scale value |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Degree of protection | IP68 / IP69K |
| Material | |
| Housing | stainless steel 1.4404 / AISI 316L O-ring for cover seal: Viton |
| Transducer | PTFE (diaphragm surface) |
| Mass | 35 g |