| General specifications | ||
|---|---|---|
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1. | |
| Output | ||
| Connection | version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 k&Omega | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Measurement accuracy | ||
| Accuracy | resolution: - version LMC5: 5 mm - version LMC15: 15 mm | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Process pressure (static pressure) | &le 16 bar (232.1 psi) | |
| Density | version S1: &ge 0.6 g/cm3 version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S1: ball &empty80 mm - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: - version LMC5: &empty14 mm, max. length 3000 mm - version LMC15: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1497 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T4...T6 | |
| Voltage | 28 V | |
| Current | 120 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-G6*-O4 and a potentiometer converter KFD2-PT2-Ex1. | |
| Versions | LMC10P6-G6P-O4 LMC10D5-G6D-O4 | |
| Output | ||
| Connection | 3-wire, potentiometer connection approx. 40 k&Omega | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Measurement accuracy | ||
| Accuracy | resolution: 10 mm | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | version PP: -10 ... 80 °C (14 ... 176 °F) version PVDF: -10 ... 100 °C (14 ... 212 °F) | |
| Process pressure (static pressure) | &le 3 bar (43.5 psi) | |
| Density | &ge 0.8 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | 3 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: - version PP: PP (Polypropylene) - version PVDF: PVDF (Polyvinylidenfluoride) terminal box: Polyester | |
| Dimensions | float: - version PP: cylinder &empty55 mm x 54 mm - version PVDF: cylinder &empty55 mm x 70 mm guide tube: &empty14 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm | |
| Process connection | thread G2A to DIN/ISO 228/1 | |
| Accessories | ||
| Optional accessories | LML-FD5 float, cylinder, Ø55 mm x 70 mm, PVDF LML-FP6 float, cylinder, Ø55 mm x 54 mm, PP | |
| General specifications | ||
|---|---|---|
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I with built-in converter and a transmitter power supply KFD2-STC4-1 or of a magnet-operated immersion probe LMC****-***-O4 and a potentiometer converter KFD2-PT2-Ex1. | |
| Output | ||
| Connection | version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 k&Omega | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Measurement accuracy | ||
| Accuracy | resolution: - version LMC5: 5 mm - version LMC15: 15 mm | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -20 ... 120 °C (-4 ... 248 °F) | |
| Process pressure (static pressure) | &le 16 bar (232.1 psi) | |
| Density | version S1: &ge 0.6 g/cm3 version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S1: ball &empty80 mm - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: - version LMC5: &empty14 mm, max. length 3000 mm - version LMC15: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm | |
| Process connection | thread G1/2A, G1-1/2A to DIN/ISO 228/1 | |
| Accessories | ||
| Optional accessories | LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Function principle | ring magnet as switching element in the float, reed contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts switching function: - version DO: with rising level NC contact - version DS: with rising leve NO contact - version DW: with rising level change-over contact | |
| Equipment architecture | A measuring system consists of a magnet-operated immersion probe LML*S*-**S-**-Ex and a (up to 3) isolated amplifier(s) with certified intrinsically safe circuit, for example KFD2-SR2-Ex1.W. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2006 , EN 61000-6-4:2011 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | -30 ... 150 °C (-22 ... 302 °F) | |
| Process pressure (static pressure) | &le 25 bar (362.6 psi) | |
| Density | version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | terminal box: -50 ... 60 °C (-58 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | max. 6 terminals, max. 2.5 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting | |
| Dimensions | float: - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 57 mm | |
| Process connection | thread G1-1/2A, G2A to DIN/ISO 228/1 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | KEMA 03 ATEX 1496 X | |
| Group, category, type of protection, temperature class | II 1/2G EEx ia IIC T3...T6 | |
| Voltage | 36 V | |
| Current | 100 mA | |
| Internal capacitance | 0 nF | |
| Internal inductance | 0 µH | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 | |
| Accessories | ||
| Optional accessories | LML-Z11 set collar, 1.4571/316Ti LML-FS2 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti LML-FS3 float, ball, Ø52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Function principle | ring magnet as switching element in the float, reed contact, change-over contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts | |
| Supply | ||
| Rated voltage | 250 V AC/DC | |
| Current consumption | 1 A | |
| Output | ||
| Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
| Directive conformity | ||
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | version PP: -10 ... 80 °C (14 ... 176 °F) version PVDF: -10 ... 100 °C (14 ... 212 °F) | |
| Process pressure (static pressure) | &le 3 bar (43.5 psi) | |
| Density | &ge 0.8 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | version LML: terminal box, max. 9 terminals version LML-PVC1: connection cable 1 m (3.3 ft), 0.75 mm2 | |
| Material | float, guide tube, process connection: - version PP: PP (Polypropylene) - version PVDF: PVDF (Polyvinylidenfluoride) connection cable: PVC terminal box: Polyester | |
| Dimensions | float: - version PP: cylinder &empty44 mm x 44 mm - version PVDF: cylinder &empty55 mm x 70 mm guide tube: - version D: &empty12 mm, max. length 1000 mm - version P: &empty16 mm, max. length 1000 mm terminal box: 80 x 82 x 55 mm | |
| Process connection | thread G3/8A, G1-1/2A, G2A to DIN/ISO 228/1 | |
| Accessories | ||
| Optional accessories | LML-Z21 set collar, PP LML-Z22 set collar, PVDF LML-FD5 float, cylinder, Ø55 mm x 70 mm, PVDF LML-FP7 float, cylinder, Ø44 mm x 44 mm, PP | |
| General specifications | ||
|---|---|---|
| Function principle | ring magnet as switching element in the float, reed contact, change-over contact number of contacts: - version LML1: 1 contact - version LML2: 2 contacts - version LML3: 3 contacts | |
| Supply | ||
| Rated voltage | 250 V AC/DC | |
| Current consumption | 1 A | |
| Output | ||
| Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. | |
| Directive conformity | ||
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2000 | |
| Operating conditions | ||
| Process conditions | ||
| Process temperature | version LML: -30 ... 150 °C (-22 ... 302 °F) version LML-PVC1: -10 ... 80 °C (14 ... 176 °F) | |
| Process pressure (static pressure) | &le 25 bar (362.6 psi) | |
| Density | version S2: &ge 0.8 g/cm3 version S3: &ge 0.7 g/cm3 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP65 | |
| Connection | version LML: terminal box, max. 9 terminals version LML-PVC1: connection cable 1 m (3.3 ft), 0.75 mm2 | |
| Material | float, guide tube, process connection: stainless steel 1.4571/316Ti connection cable: PVC terminal box: aluminum die-casting | |
| Dimensions | float: - version S2: cylinder &empty44 mm x 52 mm - version S3: ball &empty52 mm guide tube: &empty12 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm | |
| Process connection | thread G3/8A, G1-1/2A, G2A to DIN/ISO 228/1 | |
| Accessories | ||
| Optional accessories | LML-Z11 set collar, 1.4571/316Ti LML-FS2 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti LML-FS3 float, ball, Ø52 mm, 1.4571/316Ti | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Reed Contact | |
| Rated operating distance | 61 mm | |
| Installation | non-flush | |
| Mechanical life | 1 x 107 switching cycles | |
| Nominal ratings | ||
| Operating voltage | 250 V DC, 1.0 A max, 15 W | |
| Hysteresis | 15.2 mm | |
| Release point | &le max. 76 mm | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 1.83 m | |
| Core cross-section | 16 AWG | |
| Housing material | aluminum | |
| Sensing face | aluminum | |
| Housing diameter | ||
| Degree of protection | IP68 | |
| Material | ||
| Activation target | 21FR1-B | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Reed Contact | |
| Rated operating distance | 19.8 mm | |
| Installation | non-flush | |
| Output polarity | AC/DC | |
| Mechanical life | 3 x 107 operations | |
| Nominal ratings | ||
| Operating voltage | 100 V DC, 250 mA 115 V AC, 250 mA | |
| Hysteresis | &ge2.54 mm | |
| Contact resistance | 0.15 &Omega | |
| Insulation resistance | min. 100 M&Omega at 200 V | |
| Dielectric strength | 200 V AC, 60 Hz | |
| Release point | &le max. 43 mm | |
| Electrical specifications | ||
| Electrical rating | AC supply: 10 VA, 132 V AC, 750 mA DC supply: 10 W, 100 V DC, 300 mA | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 125 °C (-40 ... 257 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVDF , 914 mm according to Mil-W-81044/9 | |
| Core cross-section | 0.5 mm2 | |
| Housing material | Polycarbonate | |
| Sensing face | Polycarbonate | |
| Housing diameter | ||
| Degree of protection | IP68 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Reed Contact | |
| Rated operating distance | 19.8 mm | |
| Installation | non-flush | |
| Output polarity | AC/DC | |
| Mechanical life | 3 x 107 operations | |
| Nominal ratings | ||
| Operating voltage | 100 V DC, 250 mA 115 V AC, 250 mA | |
| Hysteresis | &ge2.54 mm | |
| Contact resistance | 0.15 &Omega | |
| Insulation resistance | min. 100 M&Omega at 200 V | |
| Dielectric strength | 200 V AC, 60 Hz | |
| Release point | &le max. 43 mm | |
| Electrical specifications | ||
| Electrical rating | AC supply: 10 VA, 132 V AC, 750 mA DC supply: 10 W, 100 V DC, 300 mA | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 125 °C (-40 ... 257 °F) | |
| Mechanical specifications | ||
| Housing material | Polycarbonate | |
| Sensing face | Polycarbonate | |
| Housing diameter | ||
| Degree of protection | IP68 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Hysteresis | 5 ... 25 % | |
| Short-circuit protection | yes | |
| Voltage drop | &le 2.5 V DC | |
| Repeat accuracy | +/- 3 % | |
| Operating current | &le 200 mA | |
| Off-state current | &le 30 mA | |
| No-load supply current | &le 40 mA | |
| Indicators/operating means | ||
| LED indicator | switching state | |
| Electrical specifications | ||
| Electrical rating | 10 - 30 V DC | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | Polycarbonate | |
| Sensing face | Polycarbonate | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Hysteresis | 5 ... 25 % | |
| Short-circuit protection | yes | |
| Voltage drop | &le 2.5 V DC | |
| Repeat accuracy | +/- 3 % | |
| Operating current | &le 200 mA | |
| Off-state current | &le 30 mA | |
| No-load supply current | &le 40 mA | |
| Indicators/operating means | ||
| LED indicator | switching state | |
| Electrical specifications | ||
| Electrical rating | 10 - 30 V DC | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | Polycarbonate | |
| Sensing face | Polycarbonate | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Hysteresis | 5 ... 25 % | |
| Short-circuit protection | yes | |
| Voltage drop | &le 2.5 V DC | |
| Repeat accuracy | +/- 3 % | |
| Operating current | &le 200 mA | |
| Off-state current | &le 30 mA | |
| No-load supply current | &le 40 mA | |
| Indicators/operating means | ||
| LED indicator | switching state | |
| Electrical specifications | ||
| Electrical rating | 10 - 30 V DC | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | Polycarbonate | |
| Sensing face | Polycarbonate | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Hysteresis | 5 ... 25 % | |
| Short-circuit protection | yes | |
| Voltage drop | &le 2.5 V DC | |
| Repeat accuracy | +/- 3 % | |
| Operating current | &le 200 mA | |
| Off-state current | &le 30 mA | |
| No-load supply current | &le 40 mA | |
| Indicators/operating means | ||
| LED indicator | switching state | |
| Electrical specifications | ||
| Electrical rating | 10 - 30 V DC | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | Polycarbonate | |
| Sensing face | Polycarbonate | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
| Installation | non-flush | |
| Output polarity | AC | |
| Nominal ratings | ||
| Operating voltage | 93 ... 132 V AC | |
| Hysteresis | 5 ... 25 % | |
| Voltage drop | 6 V at 500 mA | |
| Momentary current (20 ms, 0.1 Hz) | 1.2 A | |
| Repeat accuracy | +/- 3 % | |
| Operating current | max. 500 mA | |
| Off-state current | &le 1.5 mA | |
| Indicators/operating means | ||
| LED indicator | switching state | |
| Electrical specifications | ||
| Electrical rating | 93 - 132 V AC | |
| Ambient conditions | ||
| Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
| Installation | non-flush | |
| Output polarity | AC | |
| Nominal ratings | ||
| Operating voltage | 93 ... 132 V AC | |
| Hysteresis | 5 ... 25 % | |
| Short-circuit protection | NO | |
| Voltage drop | 6 V at 500 mA | |
| Momentary current (20 ms, 0.1 Hz) | 1.2 A | |
| Repeat accuracy | +/- 3 % | |
| Operating current | max. 500 mA | |
| Off-state current | &le 1.5 mA | |
| Indicators/operating means | ||
| LED indicator | switching state | |
| Electrical specifications | ||
| Electrical rating | 93 - 132 V AC | |
| Ambient conditions | ||
| Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 3 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |