Запасные части Pepperl+Fuchs
Каталожный номер: 126100
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 2 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Actual operating distance | 1.8 ... 2.2 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.39 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 126097
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 2 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Actual operating distance | 1.8 ... 2.2 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.39 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 126101
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 2 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.62 mm |
| Actual operating distance | 1.8 ... 2.2 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.39 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 84406
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 20 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 16.2 mm |
| Actual operating distance | 18 ... 22 mm |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.79 |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 5 mm |
| B | |
| C | |
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 250 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 3387 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | screw terminals |
| Core cross-section | &le 2.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 94271
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 20 mm |
| Installation | non-flush |
| Output polarity | AC/DC |
| Assured operating distance | 0 ... 16.2 mm |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.79 |
| Nominal ratings |
|---|
| Operating voltage | 20 ... 253 V |
| Operating voltage DC | 20 ... 300 V |
| Switching frequency | 0 ... 25 Hz |
| Hysteresis | typ. 3 % |
| Short-circuit protection | yes |
| Voltage drop | &le 4 V |
Momentary current (20 ms, 0.1 Hz) | 0 ... 3000 mA |
| Operating current | 5 ... 500 mA |
| Off-state current | 0 ... 2.5 mA typ. 1.5 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Quick disconnect type BHMS3 |
| Core cross-section | up to 2.5 mm2 |
| Housing material | PBT/metal |
| Sensing face | PBT |
| Degree of protection | IP68 |
Каталожный номер: 187851
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 20 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 16.2 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.5 |
| Reduction factor r304 | 0.6 ... 1 |
| Mounting angle | Al |
| Amplifier housing | Stainless steel |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 20 Hz |
| Hysteresis | 0.3 ... 5 typ. 2 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 25 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 7515 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | 0 ... 250 °C (32 ... 482 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Cable version | PFA cable, with armour of stainless steel |
| Core cross-section | 3 x 0.34 , screened |
| Housing material | PTFE / Al / 1.4305 / AISI 303 |
| Sensing face | PTFE |
| Degree of protection | amplifier IP67 sensor IP40 |
| Cable length | L = 10 m |
| Note | - amplifier 0 °C ... 70 °C - r1.4305 dep. on thickness of measurement plate d: r1.4305 = 1 for d < 1mm Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. |
Каталожный номер: 187524
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 20 mm |
| Installation | flush mountable |
| Output polarity | DC |
| Assured operating distance | 0 ... 16.2 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.5 |
| Reduction factor r304 | 0.6 ... 1 |
| Mounting angle | Al |
| Amplifier housing | Stainless steel |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 20 Hz |
| Hysteresis | 0.3 ... 5 typ. 2 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 25 mA |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 7515 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | 0 ... 250 °C (32 ... 482 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Cable version | PFA cable, with armour of stainless steel |
| Core cross-section | 3 x 0.34 , screened |
| Housing material | PTFE / Al / 1.4305 / AISI 303 |
| Sensing face | PTFE |
| Degree of protection | amplifier IP67 sensor IP40 |
| Cable length | L = 20 m |
| Note | - amplifier 0 °C ... 70 °C - r1.4305 dep. on thickness of measurement plate d: r1.4305 = 1 for d < 1mm Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. |
Каталожный номер: 127394
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 25 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 20 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 3.5 ... 30 V |
| Switching frequency | 500 Hz |
| Hysteresis | typ. 3 % |
| Reverse polarity protection | reverse polarity-conductive |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3.5 V |
| Temperature drift | ± 15% |
| Operating current | 2 ... 100 mA |
| Off-state current | typ. 0.8 mA |
| Switching state indicator | LED, yellow |
| Pre-fault indicator | LED, red |
| Stability control-switch point | 0,8 sr ... 0,9 sr |
| Functional safety related parameters |
|---|
| MTTFd | 1182 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 131623
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 25 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 20 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 3.5 ... 30 V |
| Switching frequency | 500 Hz |
| Hysteresis | typ. 3 % |
| Reverse polarity protection | reverse polarity-conductive |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3.5 V |
| Temperature drift | ± 15% |
| Operating current | 2 ... 100 mA |
| Off-state current | typ. 0.8 mA |
| Switching state indicator | LED, yellow |
| Pre-fault indicator | LED, red |
| Stability control-switch point | 0,8 sr ... 0,9 sr |
| Functional safety related parameters |
|---|
| MTTFd | 1182 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 182916
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 25 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 20 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 3.5 ... 30 V |
| Switching frequency | 500 Hz |
| Reverse polarity protection | reverse polarity-conductive |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3.5 V |
| Temperature drift | ± 15% |
| Operating current | 2 ... 100 mA |
| Off-state current | typ. 0.8 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 182917
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 25 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 20 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 3.5 ... 30 V |
| Switching frequency | 500 Hz |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3.5 V |
| Temperature drift | ± 15% |
| Operating current | 2 ... 100 mA |
| Off-state current | typ. 0.8 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 106307
| General specifications |
|---|
| Switching function | 2 x normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 3 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 2.43 mm |
| Actual operating distance | 2.7 ... 3.3 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 1 |
| Reduction factor rSt37 | 1.1 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| No-load supply current | &le 3 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | MINI-COMBICON |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 (Sensor side) IP20 (Connection side) |
| Tightening torque, fastening screws | M5 x 25 : 2.7 Nm |
| Note | Please use Phönix FK-MCP 1,5/4-ST-3,81 connector |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G |
Каталожный номер: 226325
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 226326
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 904455
| Описание оборудования |
|---|
| Proximity switch |
Каталожный номер: 906645
| Описание оборудования |
|---|
| Proximity switch |
Каталожный номер: 184675
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 30 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 24.3 mm |
| Actual operating distance | 27 ... 33 mm typ. |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.42 |
| Reduction factor r304 | 0.79 |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 10 mm |
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | screw terminals |
| Core cross-section | &le 2.5 mm2 |
| Housing material | PBT/metal |
| Sensing face | PBT |
| Degree of protection | IP68 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 184676
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 30 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 24.3 mm |
| Actual operating distance | 27 ... 33 mm typ. |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.42 |
| Reduction factor r304 | 0.79 |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 10 mm |
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PBT/metal |
| Sensing face | PBT |
| Degree of protection | IP68 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 181170
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | all direction LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2520 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 12 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 1D |
Каталожный номер: 89252
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | all direction LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2020 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 126081
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 3.5 ... 4.7 V typ. 4.3 V |
| Operating current | 2 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | all direction LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2020 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 10 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 126070
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 3.5 ... 4.7 V typ. 4.3 V |
| Operating current | 2 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | Multihole-LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2020 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 89256
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | all direction LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 89257
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.75 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | Multihole-LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 226331
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.36 |
| Reduction factor r304 | 0.74 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.0 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Voltage drop at IL | |
| Voltage drop IL = 20 mA, switching element on | 3.4 ... 5 V typ. 4.3 V |
| No-load supply current | &le 25 mA |
| Alternating magnetic field | 100 mT |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 226329
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.36 |
| Reduction factor r304 | 0.74 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Alternating magnetic field | 100 mT |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 87489
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | typ. 5 % |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165F |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 130 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 87490
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | typ. 5 % |
| Current consumption | |
| Measuring plate not detected | &ge 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1750 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | 4.8 mm Faston |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 129889
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.8 |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 10 mm |
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 85932
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.8 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Installation conditions | |
| A | 10 mm |
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | screw terminals |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
| Core cross-section | up to 2.5 mm2 |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.