Каталожный номер: 231574
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.37 |
| Reduction factor r304 | 0.78 |
| Nominal ratings |
|---|
| Installation conditions | |
| A | in aluminum: 25 mm in steel 1.0037 (St37): 35 mm in brass 25 mm in stainless steel 20 mm |
| B | 55 mm |
| C | 120 mm |
| F | 150 mm |
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | &le 10 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.1 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 211 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | chromium plated brass |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 231576
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.37 |
| Reduction factor r304 | 0.78 |
| Nominal ratings |
|---|
| Installation conditions | |
| A | in aluminum: 25 mm in steel 1.0037 (St37): 35 mm in brass 25 mm in stainless steel 20 mm |
| B | 55 mm |
| C | 120 mm |
| F | 150 mm |
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | &le 10 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.1 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 10 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 211 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | chromium plated brass |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 9805
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.2 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.2 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 11770 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Axial load, max. | 0 ... 1200 N |
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | Special steel |
| Housing diameter | 10 mm |
| Degree of protection | IP67 |
Каталожный номер: 199308
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.2 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.2 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Axial load, max. | 0 ... 1200 N |
| Connection type | 5 m PVC cable (suitable for drag chain) |
| Core cross-section | 0.34 mm2 |
| Housing material | Special steel |
| Housing diameter | 10 mm |
| Degree of protection | IP67 |
Каталожный номер: 106331
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.65 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. 5 % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1050 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106333
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.65 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1050 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106336
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.65 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1050 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 10 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 5 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106335
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.65 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1050 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 5 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106337
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.65 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1050 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 287110
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 0.8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.65 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 3 % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1050 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 0.085 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 183937
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.81 mm |
| Actual operating distance | 0.9 ... 1.1 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 1.5 kHz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 180094
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.35 mm |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. 5% |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads PVC , 110 mm |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 3G |
Каталожный номер: 205408
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.2 |
| Reduction factor rCu | 0.1 |
| Reduction factor r304 | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | &le 0.1 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
Каталожный номер: 205409
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.2 |
| Reduction factor rCu | 0.1 |
| Reduction factor r304 | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | &le 0.1 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
Каталожный номер: 14260
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
Каталожный номер: 89969
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
Каталожный номер: 23659
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | - |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
Каталожный номер: 14682
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2160 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Sensing face | PBT |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
Каталожный номер: 207301
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.2 |
| Reduction factor rCu | 0.1 |
| Reduction factor r304 | 0.5 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.01 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Sensing face | PBT |
| Degree of protection | IP67 |
Каталожный номер: 11617
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.24 |
| Reduction factor rCu | 0.21 |
| Reduction factor r304 | 0.67 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | 0 ... 0.1 mA typ. 0.01 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 6 mA |
| Switching state indicator | - |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.34 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
Каталожный номер: 106351
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 15 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106352
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 106356
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106358
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m , screened |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106359
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 96220
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106373
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 0.97 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 0.1 mm |
| Current consumption | |
| Measuring plate not detected | min. 2.5 mA |
| Measuring plate detected | &le 1.2 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 6 m |
| Core cross-section | 0.14 mm2 |
| Housing material | brass |
| Sensing face | PBT |
| Housing diameter | 11 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 3G 1D |
Каталожный номер: 106362
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 10 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP66 / IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G |
Каталожный номер: 201493
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 30 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 106363
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP66 / IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.