Запасные части Pepperl+Fuchs
Каталожный номер: 106366
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106367
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106368
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 205407
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.6 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | &le 0.1 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 205413
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.6 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | &le 0.1 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 205406
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. 1.5 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.6 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 2500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Voltage drop at IL | |
| Voltage drop IL = 10 mA, switching element on | 1 ... 2.2 V typ. 1.6 V |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V |
| Voltage drop IL = 50 mA, switching element on | 1.2 ... 2.4 V typ. 1.8 V |
| Voltage drop IL = 100 mA, switching element on | 1.4 ... 2.6 V typ. 2 V |
| Operating current | 0 ... 100 mA |
| Lowest operating current | 0 mA |
| Off-state current | &le 0.1 mA |
| Off-state current TU =40 °C, switching element off | &le 100 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 14262
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 255897
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 20 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Cable connector PUR , 0.14 m |
| Core cross-section | 0.14 mm2 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 15176
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 16056
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 85583
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Reduction factor rAl | 0.25 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | &le 10 µA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2190 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 916047
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.21 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.5 |
| Reduction factor r304 | 0.75 |
| Output type | 3-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1000 Hz |
| Reverse polarity protection | yes |
| Short-circuit protection | yes |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Indicators/operating means |
|---|
| Operation indicator | LED green: Power on yellow: output active |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | V3- Male connector with 200 mm PUR cable |
| Core cross-section | 0.14 mm2 |
| Housing material | Crastin (PBTB) |
| Sensing face | Crastin (PBTB) |
| Degree of protection | IP67 |
| Note | X = 200 mm |
Каталожный номер: 106374
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 1.22 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 7834 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LIFYW , 500 mm |
| Core cross-section | 0.06 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 1D |
Каталожный номер: 195694
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 1.22 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | cable in motion -5 ... 80 °C (23 ... 176 °F) , cable motionless -25 ... 80 °C (-13 ... 176 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 5 m |
| Core cross-section | 0.09 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 1D |
Каталожный номер: 217733
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 1.22 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | typ. % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | FM Class I, Div.1 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | flexible leads LIFYW , 110 mm |
| Core cross-section | 0.06 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 1D |
Каталожный номер: 86585
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, red |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Polyamide (PA) |
| Degree of protection | IP67 |
| Mass | 15 g |
| Note | Use a stop screw combined with a model -F2 sensor from Pepperl+Fuchs GmbH. The maximum actuation speed of the control slide is 0.1 m/s |
Каталожный номер: 86587
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1000 Hz |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, red |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | PA |
| Degree of protection | IP67 |
| Note | Use a stop screw combined with a model -F2 sensor from Pepperl+Fuchs GmbH. The maximum actuation speed of the control slide is 0.1 m/s |
Каталожный номер: 222511
| Описание оборудования |
|---|
| Inductive sensor |
Каталожный номер: 86589
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.215 mm |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 1000 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, red |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Polyamide (PA) |
| Degree of protection | IP67 |
| Mass | 20 g |
| Note | Use a stop screw combined with a model -F2 sensor from Pepperl+Fuchs GmbH. The maximum actuation speed of the control slide is 0.1 m/s |
Каталожный номер: 120070
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 10 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 9 typ. 5 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 4560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| FM approval | |
| Control drawing | 116-0165 |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP68 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 106473
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 10 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | typ. 3 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 21 mm |
| Degree of protection | IP68 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 1D |
Каталожный номер: 106474
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 10 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | typ. 3 % |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 4560 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.75 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 21 mm |
| Degree of protection | IP68 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G 1D |
Каталожный номер: 6722
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0 ... 10 typ. % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP68 |
Каталожный номер: 6723
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0 ... 10 typ. % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP68 |
Каталожный номер: 35513
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0 ... 10 typ. % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 10 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP68 |
Каталожный номер: 230968
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0 ... 10 typ. % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable SIHF , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP68 |
Каталожный номер: 11312
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 3 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Switching state indicator | no |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable silicone , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 911893
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 3 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Switching state indicator | no |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable silicone , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
| Note | stainless steel nuts included |
Каталожный номер: 10560
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0 ... 10 typ. % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Switching state indicator | no |
| Standard conformity |
|---|
| Standards | IEC / EN 60947-5-2:2004 |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
|---|
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
Каталожный номер: 911892
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 10 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 8.1 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 300 Hz |
| Hysteresis | 0 ... 10 typ. % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 20 mA |
| Switching state indicator | no |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable silicone , 2 m |
| Core cross-section | 0.75 mm2 |
| Housing material | PBT |
| Sensing face | PBT |
| Housing diameter | 30 mm |
| Degree of protection | IP67 |
| Note | stainless steel nuts included |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.