General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 40 a | |
Mission Time (TM) | 20 a | |
L10h | 6.8 E+9 at 6000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 90 mA | |
Linearity | ± 0.5 LSB | |
Output code | Gray code, binary code | |
Code course (counting direction) | cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | SSI | |
Monoflop time | 20 ± 10 µs | |
Resolution | ||
Single turn | 12 Bit | |
Transfer rate | 0.05 ... 1.5 MBit/s | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 0.1 ms | |
Switch-off delay | < 0.1 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Switch-on delay | < 10 ms | |
Connection | ||
Cable | &empty11.2 mm, 9-core, 2 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | ||
Gas Ex-area | -40 ... 55 °C (-40 ... 131 °F) | |
Dust Ex-area | -30 ... 55 °C (-22 ... 131 °F) | |
Storage temperature | ||
Gas Ex-area | -40 ... 70 °C (-40 ... 158 °F) | |
Dust Ex-area | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Material | ||
Housing | aluminum | |
Flange | aluminum | |
Shaft | Stainless steel | |
Mass | approx. 3400 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 400 gcm2 | |
Starting torque | &le 5 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ZELM 02 ATEX 0078 X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2012 EN 60079-1:2007 EN 60079-31:2009 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 170 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.5 ... 30 V DC | |
No-load supply current | max. 180 mA | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | Gray code, binary code | |
Code course (counting direction) | cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | SSI | |
Monoflop time | 20 ± 10 µs | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Voltage drop | UB - 2.5 V | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.5 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) | |
Signal voltage | ||
High | 4.5 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Connection | ||
Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin | |
Cable | &empty7 mm, 6 x 2 x 0.14 mm2, 1 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 (without shaft seal) DIN EN 60529, IP66/IP67 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | DIN EN 61000-6-4 | |
Noise immunity | DIN EN 61000-6-2 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 460 g (combination 1) approx. 800 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 4 mm | |
Installation | quasi flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 3.24 mm | |
Reduction factor rAl | 0.25 | |
Reduction factor rCu | 0.22 | |
Reduction factor r304 | 0.65 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 500 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.1 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 311 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M8 x 1 , 3-pin | |
Housing material | chromium plated brass | |
Sensing face | PBT | |
Housing diameter | 8 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 170 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.5 ... 30 V DC (SSI, SSI + RS422) 10 ... 30 V DC (SSI + Push/Pull) | |
No-load supply current | max. 180 mA | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | Gray code, binary code | |
Code course (counting direction) | cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | SSI SSI + incremental track | |
Monoflop time | 20 ± 10 µs | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Voltage drop | UB - 2.5 V | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.5 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Output | ||
Output type | RS422, Push/Pull | |
Signal output | A+B+/A+/B | |
Pulses | 1024, 2048, 4096 | |
Connection | ||
Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin | |
Cable | &empty7 mm, 6 x 2 x 0.14 mm2, 1 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 (without shaft seal) DIN EN 60529, IP66/IP67 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | DIN EN 61000-6-4 | |
Noise immunity | DIN EN 61000-6-2 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 460 g (combination 1) approx. 800 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 170 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | supply voltage/preset key pressed | |
LED red | internal diagnostic test failed | |
Electrical specifications | ||
Operating voltage | 4.5 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | Gray code, binary code | |
Code course (counting direction) | cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | SSI | |
Monoflop time | 20 ± 10 µs | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Voltage drop | UB - 2.5 V | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.5 ... 30 V or open input (cw ascending) | |
Low | 0 ... 1 V (cw descending) | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) | |
Signal voltage | ||
High | 4.5 ... 30 V | |
Low | 0 ... 1 V or open input | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms after falling input flank | |
Connection | ||
Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin | |
Cable | &empty7 mm, 6 x 2 x 0.14 mm2, 1 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 (without shaft seal) DIN EN 60529, IP66/IP67 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | DIN EN 61000-6-4 | |
Noise immunity | DIN EN 61000-6-2 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 460 g (combination 1) approx. 800 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | &le 30 gcm2 | |
Starting torque | < 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 40 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 90 mA | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | Gray code, binary code | |
Code course (counting direction) | see input 1 | |
Interface | ||
Interface type | SSI | |
Monoflop time | 20 ± 10 µs | |
Resolution | ||
Single turn | up to 16 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 10 ... 30 V or open input cw descending (clockwise rotation, code course descending) | |
Low | 0 ... 2 V cw ascending (clockwise rotation, code course ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Input 2 | ||
Input type | zero-set (PRESET) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Connection | ||
Cable | &Empty 10.2 mm, Radox 9 x 0.5 mm2 | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 6 mm | |
Installation | quasi flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 4.8 mm | |
Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm | |
Reduction factor rAl | 0.28 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Reduction factor rBrass | 0.35 | |
Nominal ratings | ||
Installation conditions | ||
A | in steel 1.0037 (St37): 2.4 mm in other metal: 1.2 mm | |
B | 12 mm | |
C | 18 mm | |
F | 24 mm | |
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 800 Hz | |
Hysteresis | 0.06 ... 1.2 mm | |
Reverse polarity protection | yes | |
Short-circuit protection | pulsing | |
Overload resistance | yes | |
Wire breakage protection | yes | |
Surge suppression | yes | |
Ripple | 10 % | |
Voltage drop | &le 2 V | |
Repeat accuracy | 0.3 mm | |
Operating current | 0 ... 200 mA , above 70°C max. 150 mA | |
Off-state current | &le 10 µA | |
No-load supply current | &le 15 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1740 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
EAC conformity | TR CU 020/2011 | |
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
Mass | 20 g |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 32.4 mm | |
Reduction factor rAl | 0.36 | |
Reduction factor rCu | 0.32 | |
Reduction factor r304 | 0.69 | |
Nominal ratings | ||
Installation conditions | ||
A | in aluminum: 25 mm in steel 1.0037 (St37): 35 mm in brass 25 mm in stainless steel 20 mm | |
B | 40 mm | |
C | 120 mm | |
F | 150 mm | |
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 100 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.1 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 211 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | chromium plated brass | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 40 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 90 mA | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | Gray code, binary code | |
Code course (counting direction) | see input 1 | |
Interface | ||
Interface type | SSI | |
Monoflop time | 20 ± 10 µs | |
Resolution | ||
Single turn | up to 16 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 10 ... 30 V or open input cw descending (clockwise rotation, code course descending) | |
Low | 0 ... 2 V cw ascending (clockwise rotation, code course ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Input 2 | ||
Input type | zero-set (PRESET) | |
Signal voltage | ||
High | 10 ... 30 V | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Switch-on delay | < 10 ms | |
Connection | ||
Cable | &Empty 10.2 mm, Radox 9 x 0.5 mm2 | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: Stainless steel 1.4305 / AISI 303 flange: Stainless steel 1.4305 / AISI 303 shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18371X IECEx ITS 11.0060X | |
Group, category, type of protection | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 0.8 mm | |
Installation | flush | |
Assured operating distance | 0 ... 0.65 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 3 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 1050 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 5 mm | |
Degree of protection | IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.22 mm | |
Reduction factor rAl | 0 | |
Reduction factor rCu | 0 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 400 Hz | |
Hysteresis | typ. % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Limit data | ||
Operating pressure | 350 bar (5076.4 psi) | |
Functional safety related parameters | ||
MTTFd | 10880 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Ceramic | |
Housing diameter | 18 mm | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 80 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 1 MBit/s | |
Standard conformity | communication profile: DS 301 Device profiles: DS 406 and DS 417 , programmable according to class 2 | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 IP66 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-30 , no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 550 g (combination 1) approx. 1100 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Tightening torque, fastening screws | max. 1.8 Nm | |
Shaft load | ||
Angle offset | ± 0.9 ° | |
Axial offset | static: ± 0.3 mm, dynamic: ± 0.1 mm | |
Radial offset | static: ± 0.5 mm, dynamic: ± 0.2 mm |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.22 mm | |
Reduction factor rAl | 0 | |
Reduction factor rCu | 0 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 400 Hz | |
Hysteresis | typ. % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Limit data | ||
Operating pressure | 350 bar (5076.4 psi) | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Ceramic | |
Housing diameter | 18 mm | |
Degree of protection | IP67 | |
Mass | 41.81 g | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 80 a | |
Mission Time (TM) | 20 a | |
L10h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 350 mA | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 1 MBit/s | |
Standard conformity | communication profile: DS 301 Device profiles: DS 406 and DS 417 , programmable according to class 2 | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 IP66 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-30 , no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 550 g (combination 1) approx. 1100 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 25 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 350 mA | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 1 MBit/s | |
Standard conformity | communication profile: DS 301 Device profiles: DS 406 and DS 417 , programmable according to class 2 | |
Connection | ||
Cable | &Empty 10.2 mm, Radox 9 x 0.5 mm2 | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 25 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 350 mA | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 1 MBit/s | |
Standard conformity | communication profile: DS 301 Device profiles: DS 406 and DS 417 , programmable according to class 2 | |
Connection | ||
Cable | &Empty 10.2 mm, Radox 9 x 0.5 mm2 | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: Stainless steel 1.4305 / AISI 303 flange: Stainless steel 1.4305 / AISI 303 shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18371X IECEx ITS 11.0060X | |
Group, category, type of protection | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.215 mm | |
Actual operating distance | 1.35 ... 1.65 mm typ. | |
Reduction factor rAl | 0.22 | |
Reduction factor rCu | 0.19 | |
Reduction factor r304 | 0.65 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 6.5 mm | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 80 a | |
Mission Time (TM) | 20 a | |
L10 | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | DeviceNet | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 0.5 MBit/s | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 IP66 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-30 , no moisture condensation | |
Emitted interference | DIN EN 61000-6-4 | |
Noise immunity | DIN EN 61000-6-2 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 550 g (combination 1) approx. 1100 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Tightening torque, fastening screws | max. 1.8 Nm | |
Shaft load | ||
Angle offset | ± 0.9 ° | |
Axial offset | static: ± 0.3 mm, dynamic: ± 0.1 mm | |
Radial offset | static: ± 0.5 mm, dynamic: ± 0.2 mm |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.215 mm | |
Actual operating distance | 1.35 ... 1.65 mm typ. | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 80 a | |
Mission Time (TM) | 20 a | |
L10 | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Time delay before availability | < 250 ms | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | DeviceNet | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 0.5 MBit/s | |
Connection | ||
Terminal compartment | in removable housing cover | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 IP66 (with shaft seal) | |
Climatic testing | DIN EN 60068-2-30 , no moisture condensation | |
Emitted interference | DIN EN 61000-6-4 | |
Noise immunity | DIN EN 61000-6-2 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: powder coated aluminum flange: aluminum shaft: stainless steel | |
Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
Mass | approx. 550 g (combination 1) approx. 1000 g (combination 2) | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | &le 3 Ncm (version without shaft seal) | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.215 mm | |
Actual operating distance | 1.35 ... 1.65 mm typ. | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 25 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | DeviceNet | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 0.5 MBit/s | |
Connection | ||
Cable | &Empty 10.2 mm, Radox 9 x 0.5 mm2 | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: anodized aluminum flange: aluminum, blank shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18372X IECEx ITS 15.0061X | |
Group, category, type of protection | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Device type | Singleturn absolute encoder | |
Functional safety related parameters | ||
MTTFd | 25 a | |
Mission Time (TM) | 20 a | |
L10h | 7.7 E+9 at 3000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 230 mA at 10 V DC max. 100 mA at 24 V DC | |
Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit | |
Output code | binary code | |
Code course (counting direction) | cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | DeviceNet | |
Resolution | ||
Single turn | up to 16 Bit | |
Overall resolution | up to 16 Bit | |
Transfer rate | max. 0.5 MBit/s | |
Connection | ||
Cable | &Empty 10.2 mm, Radox 9 x 0.5 mm2 | |
Terminal compartment | see ordering information | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Combination 1 | housing: Stainless steel 1.4305 / AISI 303 flange: Stainless steel 1.4305 / AISI 303 shaft: Stainless steel 1.4401 / AISI 316 | |
Combination 2 (Inox) | housing: stainless steel 1.4404 / AISI 316L flange: stainless steel 1.4404 / AISI 316L shaft: Stainless steel 1.4401 / AISI 316 | |
Mass | approx. 2600 g (combination 1) approx. 3900 g (combination 2) | |
Rotational speed | max. 3000 min -1 | |
Moment of inertia | 180 gcm2 | |
Starting torque | &le 4 Ncm | |
Shaft load | ||
Axial | 60 N | |
Radial | 80 N | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ITS 15 ATEX 18371X IECEx ITS 11.0060X | |
Group, category, type of protection | ![]() ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | IEC 60079-0:2011 EN 60079-0:2012+A11:2013 IEC 60079-1:2014 EN 60079-1:2014 IEC 60079-31:2013 EN 60079-31:2014 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 10 mm | |
Installation | flush | |
Assured operating distance | 0 ... 8.1 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 300 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 5070 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | powder coated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 180 N | |
Radial | 180 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 10 mm | |
Installation | flush | |
Assured operating distance | 0 ... 8.1 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 300 Hz | |
Hysteresis | 3 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | powder coated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 180 N | |
Radial | 180 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 12 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | powder coated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 180 N | |
Radial | 180 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 10 mm | |
Installation | flush | |
Assured operating distance | 0 ... 8.1 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 300 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP65 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 19 N | |
Radial | 44 N | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.