General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 19 N | |
Radial | 44 N | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 19 N | |
Radial | 44 N | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 15 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 12.15 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Installation conditions | ||
A | 18 mm | |
B | 30 mm | |
C | 45 mm | |
F | 90 mm | |
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 100 Hz | |
Hysteresis | 1 ... 5 typ. 3 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 4560 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Actual operating distance | 1.8 ... 2.2 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 3000 Hz | |
Hysteresis | 0.5 ... 3.5 typ. 2 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 5887 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PVDF | |
Housing diameter | 14 mm | |
Degree of protection | IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 3G 1D 3D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 40 E-8 revolutions at 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 20 N | |
Radial | 40 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 2000 Hz | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 5887 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 40 E-8 revolutions at 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 20 N | |
Radial | 40 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | 3 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 5887 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery | |
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | 3 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 5887 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery | |
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 40 E-8 revolutions at 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 20 N | |
Radial | 40 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.25 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 1000 Hz | |
Hysteresis | 0.01 ... 0.1 mm | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 130 mm | |
Core cross-section | 0.14 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | stainless steel 1.4404 / AISI 316L | |
Flange | stainless steel 1.4404 / AISI 316L | |
Shaft | Stainless steel 1.4412 / AISI 440B | |
Mass | approx. 350 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 270 N | |
Radial | 270 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | stainless steel 1.4404 / AISI 316L | |
Flange | stainless steel 1.4404 / AISI 316L | |
Shaft | Stainless steel 1.4412 / AISI 440B | |
Mass | approx. 350 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 270 N | |
Radial | 270 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 4 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 3.24 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 1500 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 11774 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty7 mm, 6 x 2 x 0.14 mm2, 1 m (cable length, see order code) | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | stainless steel 1.4404 / AISI 316L | |
Flange | stainless steel 1.4404 / AISI 316L | |
Shaft | Stainless steel 1.4412 / AISI 440B | |
Mass | approx. 350 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 270 N | |
Radial | 270 N |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 4.05 mm | |
Reduction factor rAl | 0.21 | |
Reduction factor rCu | 0.18 | |
Reduction factor r304 | 0.63 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 500 Hz | |
Hysteresis | 3 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Functional safety related parameters | ||
MTTFd | 14110 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 18 mm | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel , painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 4.05 mm | |
Reduction factor rAl | 0.21 | |
Reduction factor rCu | 0.18 | |
Reduction factor r304 | 0.63 | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 500 Hz | |
Hysteresis | 3 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 18 mm | |
Degree of protection | IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G 2G |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 256 a at 40 °C | |
Mission Time (TM) | 12 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | approx. 4 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | EtherCAT CoE (CANopen over EtherCAT, according to CiA DS-301 and DS-406 device profile CiA) | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 MBit/s / 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP66, IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | Zinc plated steel, painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel , painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 8 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 6.48 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 200 Hz | |
Hysteresis | 1 ... 7 typ. 4 % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | PBT/PPS | |
Sensing face | PBT | |
Housing diameter | 18 mm | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G 1D |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 130 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | approx. 4 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) | |
Interface | ||
Interface type | PROFINET IO | |
Resolution | ||
Single turn | up to 13 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP66, IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) at model without bus cover -40 ... 85 °C (-40 ... 185 °F) at model with bus cover | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) at model without bus cover -40 ... 85 °C (-40 ... 185 °F) at model with bus cover | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | Zinc plated steel, painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 10 mm | |
Installation | flush (Requirements: see drawing below) | |
Output polarity | DC | |
Assured operating distance | 0 ... 8.1 mm | |
Actuating element | Ferrous and nonferrous targets | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.25 | |
Reduction factor r304 | 0.85 | |
Reduction factor rSt37 | 1 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 240 Hz | |
Hysteresis | 3 ... 15 typ. 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2 V | |
Operating current | &le 200 mA | |
Off-state current | 10 µA | |
No-load supply current | &le 10 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 847 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.5 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Stainless steel 1.4305 / AISI 303 | |
Housing diameter | 18 mm | |
Degree of protection | IP69K |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 280 a at 40 °C | |
Mission Time (TM) | 12 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | approx. 2.5 W | |
Time delay before availability | < 1000 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | PROFIBUS DP DPV0, DPV1, DPV2 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | &le 12 MBit/s | |
Connection | ||
Connector | For model with axial connector outlet or connection cover with radial connector outlet: Profibus: 1 plug M12 x 1, 5-pin, B-coded 1 socket M12 x 1, 5-pin, B-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Terminal compartment | For model with connection cover with radial cable outlet | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , axial connector outlet: IP54 connection cover and shaft seal: IP66/IP67 connection cover, no shaft seal: IP65 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | Zinc plated steel, painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g for model without connection cover approx. 510 g for model with connection cover | |
Rotational speed | max. 12000 min -1 for IP54, IP65 max. 3000 min -1 for IP66/IP67 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static | |
Accessories | ||
Designation | for model without connection cover : Terminator ICZ-TR-V15B, item number 127860 (optional) |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 10 mm | |
Installation | flush (Requirements: see drawing below) | |
Output polarity | DC | |
Assured operating distance | 0 ... 8.1 mm | |
Actuating element | Ferrous and nonferrous targets | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.25 | |
Reduction factor r304 | 0.85 | |
Reduction factor rSt37 | 1 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 240 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2 V | |
Operating current | &le 200 mA | |
Off-state current | &le 10 µA | |
No-load supply current | &le 15 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 847 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Stainless steel 1.4305 / AISI 303 | |
Housing diameter | 18 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.5 ... 30 V DC (SSI, SSI + RS422) 10 ... 30 V DC (SSI + Push/Pull) | |
No-load supply current | typ. 50 mA | |
Power consumption | approx. 1.5 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI SSI + incremental track | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Output | ||
Output type | RS422, Push/Pull | |
Signal output | A+B+/A+/B | |
Pulses | 1024, 2048, 4096 | |
Connection | ||
Connector | M12 connector, 8-pin or M23 connector, 12-pin | |
Cable | &empty7 mm, 6 x 2 x 0.14 mm2, 1 m (cable length, see order code) | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 (not for M23 device plug) | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel , painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g , with cable | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 15 mm | |
Installation | flush (Requirements: see drawing below) | |
Output polarity | DC | |
Assured operating distance | 0 ... 12.15 mm | |
Actuating element | Ferrous and nonferrous targets | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.85 | |
Reduction factor rSt37 | 1 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 150 Hz | |
Hysteresis | 3 ... 15 typ. 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2 V | |
Operating current | &le 200 mA | |
Off-state current | &le 10 µA | |
No-load supply current | &le 10 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 893 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.5 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Stainless steel 1.4305 / AISI 303 | |
Housing diameter | 30 mm | |
Degree of protection | IP69K |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 55 E+8 revolutions at 40/110 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel , painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 15 mm | |
Installation | flush (Requirements: see drawing below) | |
Output polarity | DC | |
Assured operating distance | 0 ... 12.15 mm | |
Actuating element | Ferrous and nonferrous targets | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.85 | |
Reduction factor rSt37 | 1 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 150 Hz | |
Hysteresis | 3 ... 15 typ. 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2 V | |
Operating current | &le 200 mA | |
Off-state current | &le 10 µA | |
No-load supply current | &le 15 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 893 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Stainless steel 1.4305 / AISI 303 | |
Housing diameter | 30 mm | |
Degree of protection | IP67 / IP68 / IP69K - cordset dependent according to cable specification |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 256 a at 40 °C | |
Mission Time (TM) | 12 a | |
L10 | 55 E+8 revolutions at 40/110 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | approx. 4 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | EtherCAT CoE (CANopen over EtherCAT, according to CiA DS-301 and DS-406 device profile CiA) | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 MBit/s / 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | Zinc plated steel, painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 40 N | |
Radial | 110 N |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.