| Описание оборудования | ||
|---|---|---|
| Stainless steel bellows coupling | ||
| Описание оборудования | ||
|---|---|---|
| Stainless steel bellows coupling | ||
| Standard conformity | ||
|---|---|---|
| Degree of protection | DIN EN 60529, IP65 , IP66 | |
| Climatic testing | ||
| Static climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Cyclic climatic testing | DIN EN 60068-2-30 55 °C, 6 cycles | |
| Salt spray test | DIN EN 60068-2-52 , 672 h | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Ambient conditions | ||
| Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 95 °C (-40 ... 203 °F) | |
| Mechanical specifications | ||
| Shaft dimensions | Option 1: 12 x 24 mm with bore hole &empty 4 mm Option 2: 10 x 20 mm with flat area 0.5 mm | |
| Material | ||
| Housing | aluminum, coated, salt water resistant | |
| Flange | aluminum, coated, salt water resistant | |
| Shaft | stainless steel 1.4404 / AISI 316L | |
| Mass | approx. 425 g | |
| Rotational speed | max. 6000 min -1 | |
| Starting torque | &le 10 Ncm | |
| Shaft load | ||
| Axial | 200 N | |
| Radial | 350 N | |
| Life span | 3 x 109 @ 3000 min-1 | |
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Описание оборудования | ||
|---|---|---|
| Guide pulley for cable pulls SL30.../GS130 and SL30.../GS190 | ||
| Описание оборудования | ||
|---|---|---|
| Guide pulley | ||
| Описание оборудования | ||
|---|---|---|
| Stainless steel bellows coupling | ||
| Описание оборудования | ||
|---|---|---|
| Helical coupling | ||
| Functional safety related parameters | ||
|---|---|---|
| Safety Integrity Level (SIL) | SIL 3 | |
| Performance level (PL) | PL e | |
| Mission Time (TM) | 20 a | |
| PFHd | 7.85 E-9 | |
| Electrical specifications | ||
| Rated operating current | &le 350 mA / &le 4 A from AUX | |
| Interface 1 | ||
| Interface type | Chip card slot | |
| Interface 2 | ||
| Interface type | Micro USB | |
| Input | ||
| Number/Type | 2 inputs for incremental rotary encoders AMP mini-IO connector | |
| Signal delay | 100 ms at 1015 Hz < flimit 140 ms at 45 Hz < flimit < 1015 Hz 700 ms at flimit < 45 Hz | |
| Signal frequency | Parameterization range 25 Hz &hellip 200 kHz | |
| Output | ||
| Number/Type | Output circuits 1 and 2 max. contact rating: 700 m ADC-13 at 24  V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | removable terminals | |
| Material | ||
| Housing | PA 66-FR | |
| Mounting | DIN mounting rail | |
| General information | ||
| Scope of delivery | 1 AS-Interface safety module VAS/M-2A8L-KE4-8SE-C1 1 AS-Interface safety module VBA-2E-KE4-ENC-S | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 104 mm | |
| Linearity range | 1 ... 103 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 125 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 320 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | ABS | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.4 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 2000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 3-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog current output with PNP binary NO | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 80 mm | |
| Linearity range | 1 ... 79 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 125 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Switching window | ± 1 mm | |
| Switching hysteresis | 0.4 mm | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA | |
| Load resistor | &le 400 &Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | ABS | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 80 mm | |
| Linearity range | 1 ... 79 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 125 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 419 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | ABS | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Switching output | ||
| Output type | 2 Push-pull (4 in 1) outputs , short-circuit protected , reverse polarity protected , overvoltage protected , programmable | |
| Operating current | &le 100 mA / output | |
| Switching hysteresis | 3-step, adjustable 0.2 m ... 0.8 mm | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 4-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Switching output | ||
| Output type | 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable | |
| Operating current | &le 100 mA / output | |
| Switching hysteresis | 3-step, adjustable 0.2 m ... 0.8 mm | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 2 m PUR cable , screened | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Switching output | ||
| Output type | 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable | |
| Operating current | &le 100 mA / output | |
| Switching hysteresis | 3-step, adjustable 0.2 m ... 0.8 mm | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Analog output | ||
| Output type | voltage output 0 ... 10 V | |
| Load resistor | &ge 2000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 2 m PUR cable , screened | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Analog output | ||
| Output type | voltage output 0 ... 10 V | |
| Load resistor | &ge 2000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 4-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Analog output | ||
| Output type | voltage output 0 ... 5 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 4-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | PNP | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Voltage drop | &le 3 V | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 880 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Switching output | ||
| Output type | PNP (2 Channels) | |
| Operating current | per channel 50 mA , Combined max. 80 mA | |
| Switching window | position programmable, width 2 mm | |
| Switching hysteresis | 0.4 mm | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5 x 0.14 mm2 , screened 2 m PUR cable | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 95 g | |
| General specifications | ||
|---|---|---|
| Switching element function | PNP | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Voltage drop | &le 3 V | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 880 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Switching output | ||
| Output type | PNP (2 Channels) | |
| Operating current | per channel 50 mA , Combined max. 80 mA | |
| Switching window | position programmable, width 2 mm | |
| Switching hysteresis | 0.4 mm | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Male cordset, M12 , 5-pin 1 m, PUR cable, shielded | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 75 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | current limit | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5 x 0.14 mm2 , screened 2 m PUR cable | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 95 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | current limit | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Male cordset, M12 , 5-pin 1 m, PUR cable, shielded | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 75 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.4 mm | |
| No-load supply current | &le 20 mA | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Male cordset, M12 , 5-pin 1 m, PUR cable | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 71 g | |
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.