| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.4 mm | |
| No-load supply current | &le 20 mA | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 1 m, PUR cable | |
| Core cross-section | 5 x 0.25 mm2 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 65 g | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 210 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.2 mm | |
| Resolution | 210 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 310 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing length L | 250 mm | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PA 6 / AL | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. | |
| General specifications | ||
|---|---|---|
| Measurement range | max. 360° min. 45° | |
| Adjustment range | 360° | |
| Rotational speed | max. 100 min-1 | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Repeat accuracy | ± 0.25 ° | |
| Resolution | 0.2 ° | |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) | |
| No-load supply current | &le 45 mA | |
| Functional safety related parameters | ||
| MTTFd | 450 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| LED PWR/ERR | LED green / red | |
| LED U/I | Activator within measuring range | |
| Analog output | ||
| Output type | current output or voltage output (load dependend) 4 ... 20 mA (RL < 400 &Omega) 0 ... 10 V (RL > 3.3 k&Omega) | |
| Linearity error | ± 0.6 ° , (with original actuator) | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 180 g | |
| General specifications | ||
|---|---|---|
| Measurement range | max. 360° min. 90° | |
| Adjustment range | 2 switch frames programmable , min. 5°, max. 360° | |
| Rotational speed | max. 100 min-1 | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Repeat accuracy | ± 0.25 ° | |
| Resolution | 0.2 ° | |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) | |
| No-load supply current | &le 45 mA | |
| Indicators/operating means | ||
| LED yellow 1 | switching state, Switching output 1 | |
| LED yellow 2 | switching state, Switching output 2 | |
| LED PWR/ERR | Status display LED, green/red (Power on / missing actuator / keylock) | |
| LED U/I | Activator within measuring range | |
| Switching output | ||
| Output type | 2 switch outputs NPN, NO , reverse polarity protected , short-circuit protected , programmable | |
| Operating current | &le 100 mA | |
| Switching hysteresis | 1 ° | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Analog output | ||
| Output type | current output or voltage output (load dependend) 4 ... 20 mA (RL < 400 &Omega) 0 ... 10 V (RL > 3.3 k&Omega) | |
| Linearity error | ± 0.6 ° , (with original actuator) | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 180 g | |
| General specifications | ||
|---|---|---|
| Measurement range | max. 360° min. 45° | |
| Adjustment range | 2 switch frames programmable , min. 5°, max. 360° | |
| Rotational speed | max. 100 min-1 | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Repeat accuracy | ± 0.25 ° | |
| Resolution | 0.2 ° | |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) | |
| No-load supply current | &le 45 mA | |
| Functional safety related parameters | ||
| MTTFd | 450 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| LED yellow 1 | switching state, Switching output 1 | |
| LED yellow 2 | switching state, Switching output 2 | |
| LED PWR/ERR | Status display LED, green/red (Power on / missing actuator / keylock) | |
| LED U/I | Activator within measuring range | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable | |
| Operating current | &le 100 mA | |
| Switching hysteresis | 1 ° | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Analog output | ||
| Output type | current output or voltage output (load dependend) 4 ... 20 mA (RL < 400 &Omega) 0 ... 10 V (RL > 3.3 k&Omega) | |
| Linearity error | ± 0.6 ° , (with original actuator) | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 180 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog current output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 40 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 60 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 202 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | current output 4 ... 20 mA | |
| Load resistor | current output &le 500 &Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 40 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 60 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 202 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | voltage output 0 ... 10 V | |
| Load resistor | voltage output: &ge 1000 &Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 810 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.8 mm | |
| Repeat accuracy | ± 0.4 mm | |
| Resolution | 950 µm | |
| Temperature drift | ± 1 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 70 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 120 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing length L | 850 mm | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PA 6 / AL | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. The path measurement system must be secured at 20 cm intervals to prevent mechanical load. | |
| General specifications | ||
|---|---|---|
| Measurement range | max. 180° min. 90° | |
| Adjustment range | 180° , 2 switch frames programmable | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Repeat accuracy | ± 0.25 ° | |
| Resolution | 0.2 ° | |
| Temperature drift | 0.02 ° / °C (-25 °C ... 70 °C) | |
| No-load supply current | &le 45 mA | |
| Functional safety related parameters | ||
| MTTFd | 234 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| LED yellow 1 | switching state, Switching output 1 | |
| LED yellow 2 | switching state, Switching output 2 | |
| LED PWR/ERR | Status display LED, green/red (Power on / missing actuator / keylock) | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable | |
| Operating current | &le 100 mA | |
| Switching hysteresis | 1 ° | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Analog output | ||
| Output type | current output 3.8 ... 20.5 mA (RL < 400 &Omega) | |
| Linearity error | ± 1.5 ° , (with original actuator) | |
| Transfer characteristics | ||
| Internal measurement cycle | 30 ms | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 180 g | |
| Описание оборудования | ||
|---|---|---|
| Position sensor for PAX001 | ||
| Описание оборудования | ||
|---|---|---|
| R2000 Detection, 2-D LiDAR sensor for precise field monitoring, measuring range to object up to 10 m | ||
| Описание оборудования | ||
|---|---|---|
| R2000 Detection, 2-D LiDAR sensor for precise field monitoring, measuring range to object up to 30 m | ||
| Описание оборудования | ||
|---|---|---|
| Measurement to object, 100 mm detection range, red light, measured value via IO-Link, 2 x push-pull output, M8 plug | ||
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 960 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.9 mm | |
| Repeat accuracy | ± 0.4 mm | |
| Resolution | 960 µm | |
| Temperature drift | ± 0.9 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 70 mA | |
| Operating voltage indicator | LED green | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M12 connector | |
| Housing material | PA 6 / AL | |
| Housing length L | 1000 mm | |
| Degree of protection | IP65 | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. The path measurement system must be secured at 20 cm intervals to prevent mechanical load. | |
| Описание оборудования | ||
|---|---|---|
| Measurement to object, 100 mm detection range, red laser light, laser class 1, measured value via IO-Link, 2 x push-pull output, M8 plug | ||
| Описание оборудования | ||
|---|---|---|
| Measurement to object, 100 mm detection range, red light, measured value via IO-Link, 2 x push-pull output, M8 plug | ||
| Описание оборудования | ||
|---|---|---|
| Measurement to object, 100 mm detection range, red laser light, laser class 1, measured value via IO-Link, 2 x push-pull output, M8 plug | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, PROFIBUS, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 150 m, SSI interface - switchable to RS-422, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, PROFIBUS, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 300 m, SSI interface - switchable to RS-422, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, PROFIBUS, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Distance sensor for positioning tasks accurate to the millimeter, PRT, measuring range up to 50 m, SSI interface - switchable to RS-422, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Universal distance sensor, measurement to object, 100 mm detection range, red laser light, laser class 2, PNP output, analog output, control input, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Universal distance sensor, measurement to object, 300 mm detection range, red laser light, laser class 2, RS485 interface, 2 x PNP outputs, analog output, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Universal distance sensor, measurement to object, 300 mm detection range, red laser light, laser class 2, PNP output, analog output, control input, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Universal distance sensor, measurement to object, IO-Link interface, measuring method PRT, 15 m detection range, red laser light, laser class 1, push-pull output, analog output, M12 plug | ||
| Описание оборудования | ||
|---|---|---|
| Universal distance sensor, measurement to reflector, IO-Link interface, measuring method PRT, 50 m detection range, red laser light, laser class 1, push-pull output, analog output, M12 plug | ||
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.