General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | AC/DC | |
Reduction factor rAl | 0.5 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 250 V AC/20 ... 300 V DC | |
Switching frequency | 30 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Voltage drop | &le 8 V | |
Operating current | 4 ... 500 mA AC/DC | |
Off-state current | &le 0.8 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 5 m | |
Core cross-section | 0.5 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Rail or terminals 23+, 24- | |
Rated voltage | 19 ... 30 V | |
Rated current | approx. 140 mA at 24 V DC | |
Power dissipation | 2.7 W | |
Power consumption | 3.3 W | |
HART signal channels (intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 1, 2, 3, 4, 5, 6 | |
Open circuit voltage/short-circuit current | typ. 24 V / 28 mA | |
Input resistance | 250 &Omega , 5 % (terminals 2, 3 and with jumper on 5, 6) | |
Available voltage | &ge 15.5 V at 20 mA, short-circuit protected | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 10, 11, output II: terminals 11, 12, output III: terminals 16, 17, output IV: terminals 17, 18 output V: terminals 7, 8, 9, output VI: terminals 13, 14, 15, output VII: terminals 19, 20, 21 | |
Output I, II, III, IV | ||
Output signal | relay and LED yellow | |
Mechanical life | 107 switching cycles | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Output V, VI, VII | ||
Output signal | analog | |
Current range | 4 ... 20 mA , (source or sink mode) | |
Load | max. 650 &Omega , source mode | |
Voltage range | 5 ... 30 V , sink mode from external supply | |
Fault signal | downscale I &le 2 mA, upscale I &ge 21.5 mA (acc. NAMUR NE43) or hold measurement value | |
Other outputs | HART communicator on terminals 22, 24 | |
Collective error message | Power Rail and LED red | |
Transfer characteristics | ||
Relay | programmable either for fault or trip value (with direction, hysteresis and delay) | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons via PACTware | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BASEEFA 07 ATEX 0174 | |
Marking | ![]() | |
Certificate | PF 07 CERT 1141 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 116-0129 | |
IECEx approval | ||
IECEx certificate | IECEx BAS 07.0047 | |
IECEx marking | [Ex ia] IIC , [Ex iaD] |
Functional safety related parameters | ||
---|---|---|
Safety Integrity Level (SIL) | SIL 3 | |
Supply | ||
Connection | SL1: 1a, 1b(-) 2a, 2b(+) | |
Rated voltage | 20.4 ... 30 V DC via Termination Board | |
Rated current | 28 mA at 24 V , RS-485, quiescent current | |
Power dissipation | 0.7 W at 24 V | |
HART signal channels (non-intrinsically safe) | ||
Number of channels | 32 | |
Conformity | HART field device input (revision 5 to 7) | |
Signal range | 0.12 Vpp < signal < 1.5 Vpp | |
Leakage current | < 3 µA at -20 ... 85 °C (-4 ... 185 °F) | |
Terminating resistor | external 230 ... 500 &Omega standard (up to 1000 &Omega possible) | |
Output voltage | &ge 400 mV ss (with the terminator resistance specified above) | |
Output resistance | 100 &Omega or smaller, capacitive coupling | |
DC isolation | dual capacitor each channel | |
Common mode voltage | up to 30 V | |
Input impedance | > 5 k&Omega , according to HART specification | |
Input voltage range | 0.12 ... 1.5 V ss | |
Common mode voltage | max. 30 V | |
Differential mode clamping | ± 5.2 V , for transient or AC signals | |
Common mode clamping | ± 10 V , for transient or AC signals | |
Carrier detect level | signal > 0.12 Vpp, carrier detection activated signal < 0.08 Vpp, carrier detection not activated | |
Transmit amplitude | 200 &Omega load, 0.43 Vpp < signal < 0.49 Vpp 500 &Omega load, 1.1 Vpp < signal < 1.2 Vpp | |
Device type | DC isolated bus device | |
Impedance | high impedance | |
Data link type | HART primary and secondary | |
Field multi point support | option available upon request | |
Interface | ||
Transfer rate | 9600 MBit/s, 19200 MBit/s or 38400 MBit/s, selectable via switch | |
Address | 1 ... 31 , adjustable via DIP switch | |
Type | RS-485 , differential pair and grounding | |
Topology | multi point, master/slave connection | |
Indicators/settings | ||
Display elements | LEDs LED PWR ON (power supply), one green LED LED HART TX (HART transmission), one yellow LED LED FAULT (lead fault), one red LED | |
Control elements | DIP switches at the housing side for: - unit slave address - baud rate - test mode on/off | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 140 g | |
Dimensions | 18 x 106 x 128 mm (0.7 x 4.2 x 5 inch) | |
Mounting | on Termination Board | |
Data for application in connection with hazardous areas | ||
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
CSA approval | 1256050 | |
Approved for | Class I, Division 2, Groups A, B, C, D Class I, Zone 2, IIC |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Electrical specifications | ||
Rated voltage | 33 V | |
Rated current | 500 mA | |
Voltage protection level | ||
Line/Line | max. 58 V category C1/C2 8/20µsec max. 50 V category C3 1kV/µsec max. 51 V category B2 10/700µsec max. 55 V category D1 10/350µsec | |
Line/Earth | max. 1400 V category C1/C2 8/20µsec max. 1100 V category C1/C2 1kV/µsec max. 1000 V category B2 10/700µsec max. 1300 V category D1 10/350µsec | |
Screen/Shield directly grounded | max. 25 V category C1/C2 8/20µsec max. 20 V category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C2 8/20µsec max. 600 V category C3 1kV/µsec max. 500 V category B2 10/700µsec max. 600 V category D1 10/350µsec | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) | |
Series resistance in line | 1 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec | |
Screen/Shield directly grounded | 5 kA category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec | |
Capacitance | ||
Line/Line | 800 pF | |
Line/Earth | 16 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | Protection Module 20 g , base module 40 g | |
Mounting | 35 mm DIN mounting rail | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 09 ATEX 0191 X | |
Marking | ![]() | |
Voltage | 30 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Internal inductance | negligible 0 µH | |
Certificate | KEMA 09 ATEX 0190 X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
International approvals | ||
CSA approval | CSA 2437472 | |
Control drawing | 116-0361 | |
Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | |
IECEx approval | IECEx KEM 09.0088X | |
Approved for | Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc | |
Certificates and approvals | ||
Marine approval | pending |
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Electrical specifications | ||
Rated voltage | 32 V | |
Nominal discharge current (8/20 µs) | ||
per line | 10 kA | |
total | 10 kA | |
Max. surge current (8/20 µs) | 10 kA | |
Voltage protection level at max. rated current | ||
Line/Line | 58 V | |
Line/Earth | 1700 V | |
Voltage protection level at 1 kV/µsec | ||
Line/Line | 50 V | |
Line/Earth | 1.2 kV | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Capacitance | ||
Line/Line | 25 pF | |
Line/Earth | 15 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | IEC 61158-2 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Mechanical specifications | ||
Core cross-section | 1.3 mm2 | |
Housing material | Stainless steel 1.4401 (AISI 316) surface all over polished | |
Degree of protection | IP00/IP67 if correctly installed | |
Mass | 160 g | |
Mounting | screw mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 04 ATEX 2318 X | |
Marking | ![]() | |
Maximum values | ||
Rated voltage | 32 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-1:2007 | |
International approvals | ||
IECEx approval | IECEx KEM 09.0067X | |
Approved for | Ex d IIC T5/T6 Gb | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | AC/DC | |
Reduction factor rAl | 0.5 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 250 V AC/20 ... 300 V DC | |
Switching frequency | 30 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Voltage drop | &le 8 V | |
Operating current | 4 ... 500 mA AC/DC | |
Off-state current | &le 0.8 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 3-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Electrical specifications | ||
Rated voltage | 32 V | |
Rated current | 550 mA | |
Nominal discharge current (8/20 µs) | ||
per line | 10 kA | |
total | 10 kA | |
Max. surge current (8/20 µs) | 10 kA | |
Voltage protection level at max. rated current | ||
Line/Line | 58 V | |
Line/Earth | 1700 V | |
Voltage protection level at 1 kV/µsec | ||
Line/Line | 50 V | |
Line/Earth | 1.2 kV | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Capacitance | ||
Line/Line | 25 pF | |
Line/Earth | 15 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | IEC 61158-2 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Mechanical specifications | ||
Core cross-section | 1.3 mm2 | |
Housing material | Stainless steel 1.4401 (AISI 316) surface all over polished | |
Degree of protection | IP00/IP67 if correctly installed | |
Mass | 160 g | |
Mounting | screw mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 04 ATEX 1317 X | |
Marking | ![]() | |
Voltage | Entity 30 V , FISCO 17.5 V | |
Current | Entity 550 mA , FISCO 380 mA | |
Power | Entity 3 W , FISCO 5.32 W | |
Internal capacitance | negligible 0 nF | |
Internal inductance | negligible 0 µH | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-26:2007 | |
International approvals | ||
IECEx approval | IECEx KEM 09.0081X | |
Approved for | Ex ia [ia Ga] IIC T5/T6 Gb | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version SCP-LBF-IA1.36.IE.1) , max. 0 mA (for version SCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required (for version SCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 250 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 53 V category C1 8/20µsec , 150 A max. 55 V category C2 8/20µsec , 150 A max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 980 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 50 A per line max. 1450 V category C2 8/20µsec , 5 kA per line max. 1200 V category C3 1kV/µsec , 50 A per line max. 980 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 700 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 2 | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 45 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version TCP-LBF-IA1.36.IE.1) , max. 0 mA (for version TCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required , (for version TCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 600 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 50 V category C1 8/20µsec , 300 A max. 55 V category C2 8/20µsec , 5 kA max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 1060 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 300 A per line max. 1.5 kV category C2 8/20µsec , 5 kA per line max. 1.3 kV category C3 1kV/µsec , 50 A per line max. 1080 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 720 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 | |
Series resistance in line | 2 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 80 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | AC/DC | |
Reduction factor rAl | 0.5 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 250 V AC/20 ... 300 V DC | |
Switching frequency | 30 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Voltage drop | &le 8 V | |
Operating current | 4 ... 500 mA AC/DC | |
Off-state current | &le 0.8 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector 7/8 inch-16 UN , 3-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version TPH-LBF-IA1.36.DE.1) , max. 0 mA (for version TPH-LBF-IA1.36.DE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required , (for version TPH-LBF-IA1.36.DE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 600 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 52 V category C1 8/20µsec , 300 A max. 55 V category C2 8/20µsec , 5 kA max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 1060 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 300 A per line max. 1450 V category C2 8/20µsec , 5 kA per line max. 1300 V category C3 1kV/µsec , 50 A per line max. 1080 V category D1 10/350µsec , 500 A per line | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 | |
Series resistance in line | 2 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 45 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 1, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Electrical specifications | ||
Rated voltage | 33 V | |
Rated current | 500 mA | |
Voltage protection level | ||
Line/Line | max. 58 V category C1/C2 8/20µsec max. 50 V category C3 1kV/µsec max. 51 V category B2 10/700µsec max. 55 V category D1 10/350µsec | |
Line/Earth | max. 1400 V category C1/C2 8/20µsec max. 1100 V category C1/C2 1kV/µsec max. 1000 V category B2 10/700µsec max. 1300 V category D1 10/350µsec | |
Screen/Shield directly grounded | max. 25 V category C1/C2 8/20µsec max. 20 V category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C2 8/20µsec max. 600 V category C3 1kV/µsec max. 500 V category B2 10/700µsec max. 600 V category D1 10/350µsec | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) | |
Series resistance in line | 1 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec | |
Screen/Shield directly grounded | 5 kA category D1 10/350µsec | |
Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec | |
Capacitance | ||
Line/Line | 800 pF | |
Line/Earth | 16 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | Protection Module 20 g , base module 40 g | |
Mounting | 35 mm DIN mounting rail | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 09 ATEX 0191 X | |
Marking | ![]() | |
Voltage | 30 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Internal inductance | negligible 0 µH | |
Certificate | KEMA 09 ATEX 0190 X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 500 mA | |
Internal capacitance | negligible 0 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
International approvals | ||
CSA approval | CSA 2437472 | |
Control drawing | 116-0361 | |
Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | |
IECEx approval | IECEx KEM 09.0088X | |
Approved for | Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc | |
Certificates and approvals | ||
Marine approval | pending |
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Electrical specifications | ||
Rated voltage | 32 V | |
Nominal discharge current (8/20 µs) | ||
per line | 10 kA | |
total | 10 kA | |
Max. surge current (8/20 µs) | 10 kA | |
Voltage protection level at max. rated current | ||
Line/Line | 58 V | |
Line/Earth | 1700 V | |
Voltage protection level at 1 kV/µsec | ||
Line/Line | 50 V | |
Line/Earth | 1.2 kV | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Capacitance | ||
Line/Line | 25 pF | |
Line/Earth | 15 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | IEC 61158-2 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Mechanical specifications | ||
Core cross-section | 1.3 mm2 | |
Housing material | Stainless steel 1.4401 (AISI 316) surface all over polished | |
Degree of protection | IP00/IP67 if correctly installed | |
Mass | 160 g | |
Mounting | screw mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 04 ATEX 2318 X | |
Marking | ![]() | |
Maximum values | ||
Rated voltage | 32 V | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-1:2007 | |
International approvals | ||
IECEx approval | IECEx KEM 09.0067X | |
Approved for | Ex d IIC T5/T6 Gb | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | AC/DC | |
Reduction factor rAl | 0.5 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 250 V AC/20 ... 300 V DC | |
Switching frequency | 30 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Short-circuit protection | yes | |
Voltage drop | &le 8 V | |
Operating current | 4 ... 500 mA AC/DC | |
Off-state current | &le 0.8 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1036 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 5 m | |
Core cross-section | 0.5 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Electrical specifications | ||
Rated voltage | 32 V | |
Rated current | 550 mA | |
Nominal discharge current (8/20 µs) | ||
per line | 10 kA | |
total | 10 kA | |
Max. surge current (8/20 µs) | 10 kA | |
Voltage protection level at max. rated current | ||
Line/Line | 58 V | |
Line/Earth | 1700 V | |
Voltage protection level at 1 kV/µsec | ||
Line/Line | 50 V | |
Line/Earth | 1.2 kV | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Capacitance | ||
Line/Line | 25 pF | |
Line/Earth | 15 pF | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | IEC 61158-2 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) | |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) | |
Mechanical specifications | ||
Core cross-section | 1.3 mm2 | |
Housing material | Stainless steel 1.4401 (AISI 316) surface all over polished | |
Degree of protection | IP00/IP67 if correctly installed | |
Mass | 160 g | |
Mounting | screw mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | KEMA 04 ATEX 1317 X | |
Marking | ![]() | |
Voltage | Entity 30 V , FISCO 17.5 V | |
Current | Entity 550 mA , FISCO 380 mA | |
Power | Entity 3 W , FISCO 5.32 W | |
Internal capacitance | negligible 0 nF | |
Internal inductance | negligible 0 µH | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-26:2007 | |
International approvals | ||
IECEx approval | IECEx KEM 09.0081X | |
Approved for | Ex ia [ia Ga] IIC T5/T6 Gb | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version SCP-LBF-IA1.36.IE.1) , max. 0 mA (for version SCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required (for version SCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 250 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 53 V category C1 8/20µsec , 150 A max. 55 V category C2 8/20µsec , 150 A max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 980 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 50 A per line max. 1450 V category C2 8/20µsec , 5 kA per line max. 1200 V category C3 1kV/µsec , 50 A per line max. 980 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 700 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 2 | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 45 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | AC/DC | |
Reduction factor rAl | 0.5 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 250 V AC/20 ... 300 V DC | |
Switching frequency | 30 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Short-circuit protection | yes | |
Voltage drop | &le 8 V | |
Operating current | 4 ... 500 mA AC/DC | |
Off-state current | &le 0.8 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1036 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector 1/2"-20 UN , 3-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version TCP-LBF-IA1.36.IE.1) , max. 0 mA (for version TCP-LBF-IA1.36.IE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required , (for version TCP-LBF-IA1.36.IE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 600 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 50 V category C1 8/20µsec , 300 A max. 55 V category C2 8/20µsec , 5 kA max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 1060 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 300 A per line max. 1.5 kV category C2 8/20µsec , 5 kA per line max. 1.3 kV category C3 1kV/µsec , 50 A per line max. 1080 V category D1 10/350µsec , 500 A per line | |
Screen/Shield indirectly grounded (via GDT) | max. 500 V category B2 10/700µsec , 100 A max. 600 V category C1 8/20µsec , 500 A max. 720 V category C2 8/20µsec , 10 kA max. 550 V category C3 1kV/µsec , 100 A max. 570 V category D1 10/350µsec , 1 kA | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Screen/Shield-Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 | |
Series resistance in line | 2 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Screen/Shield indirectly grounded (via GDT) | 1 kA category D1 10/350µsec 10 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 80 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 | |
Certificates and approvals | ||
Marine approval | DNV A-14038 |
General specifications | ||
---|---|---|
Design / Mounting | Cabinet installation | |
Fieldbus interface | ||
Self current consumption | max. 6 mA (for version TPH-LBF-IA1.36.DE.1) , max. 0 mA (for version TPH-LBF-IA1.36.DE.0) | |
Indicators/operating means | ||
LED ERR | green flashing: status OK , red flashing: maintenance required , (for version TPH-LBF-IA1.36.DE.1) | |
Electrical specifications | ||
Rated voltage | 36 V | |
Rated current | 600 mA | |
Voltage protection level | ||
Line/Line | max. 50 V category B2 10/700µsec , 25 A max. 52 V category C1 8/20µsec , 300 A max. 55 V category C2 8/20µsec , 5 kA max. 46 V category C3 1kV/µsec , 10 A | |
Line/Earth | max. 1060 V category B2 10/700µsec , 50 A per line max. 800 V category C1 8/20µsec , 300 A per line max. 1450 V category C2 8/20µsec , 5 kA per line max. 1300 V category C3 1kV/µsec , 50 A per line max. 1080 V category D1 10/350µsec , 500 A per line | |
Reaction time | ||
Line/Line | max. 1 ns | |
Line/Earth | max. 100 ns | |
Overstressed fault mode | acc. IEC 61643-21 line inoperable mode 3 | |
Series resistance in line | 2 &Omega +/- 5 % | |
Impulse durability | ||
Per line | 5 kA category C2 8/20µsec | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | IEC 60721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Surge protection | IEC 61643-21 | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | &le 95 % non-condensing | |
Shock resistance | 15 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Connection type | screw terminals | |
Core cross-section | flexible wire 2.5 mm2 solid wire max. 4 mm2 | |
Housing material | Polyamide PA 6.6 | |
Degree of protection | IP20 | |
Mass | 45 g | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | SIRA 12 ATEX 2128X | |
Marking | ![]() | |
Voltage | 24 V | |
Current | 500 mA | |
Internal capacitance | 2 nF | |
Internal inductance | 0.1 µH | |
Certificate | SIRA 12 ATEX 4176X | |
Marking | ![]() ![]() | |
Voltage | 33 V | |
Current | 600 mA | |
Internal capacitance | 2 nF | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 | |
Supplementary information | FISCO field device | |
International approvals | ||
CSA approval | CoC 2595441 | |
Control drawing | 116-0365 | |
Approved for | Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 1, Ex ia IIC T4 Class I, Zone 2, Ex ic IIC T4 Class I, Zone 0, AEx ia IIC T4 Class I, Zone 2, AEx ic IIC T4 Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 2, Ex nL IIC T4 Class I, Zone 2, Ex na IIC T4 Class I, Zone 2, AEx nAc IIC T4 | |
IECEx approval | IECEx SIR 12.0051X | |
Approved for | Ex ia IIC T4 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | AC/DC | |
Reduction factor rAl | 0.5 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 250 V AC/20 ... 300 V DC | |
Switching frequency | 30 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Short-circuit protection | yes | |
Voltage drop | &le 8 V | |
Operating current | 4 ... 500 mA AC/DC | |
Off-state current | &le 0.8 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1036 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector 7/8 inch-16 UN , 3-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.3, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
RoHs | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | Aluminum | |
Mass | approx. 1000 g | |
Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BVS 17 ATEX E 029 | |
Marking | ![]() ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0435 | |
IECEx approval | ||
IECEx certificate | IECEX BVS 17.0023 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.3, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
RoHs | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | quasi flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 12.15 mm | |
Actual operating distance | 13.5 ... 16.5 mm | |
Reduction factor rAl | 0.33 | |
Reduction factor rCu | 0.28 | |
Reduction factor r304 | 0.81 | |
Nominal ratings | ||
Operating voltage | 20 ... 253 V | |
Switching frequency | 0 ... 20 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
Operating current | 5 ... 200 mA | |
Off-state current | 0 ... 1.7 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.75 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP67 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.3, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
RoHs | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BVS 17 ATEX E 029 | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014 | |
International approvals | ||
IECEx approval | ||
IECEx certificate | IECEX BVS 17.0023 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) |
Supply | ||
---|---|---|
Rated voltage | 7 ... 30 V DC | |
Rated current | < 1 mA , max. 25 mA | |
Electrical specifications | ||
Output rated operating current | 3.2 ... 25 mA | |
Supply | loop power for field devices voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V | |
Input | ||
Connection | - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | up to 8 HART field devices (depending on installation) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013+A11:2013 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300 328 V1.8.1:2012 EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012-09 | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Material | Aluminum alloy with polyurethane enamel paint | |
Mass | 460 g | |
Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | FM 11 ATEX 0019 X | |
Marking | ![]() ![]() | |
Certificate | FM 11 ATEX 0068 X | |
Marking | ![]() | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | CoC3040786(C) | |
Approved for | Class I, Zone 0, (A)Ex ia IIC T6/T5 Ga Class I, Zone 2, (A)Ex nA IIC T6/T5 Gc Class I, Zone 20, (A)Ex ia IIIC T95°C Da Class I, Division 1, Groups A - D Class II, Division 1, Groups E - G Class III Class I, Division 2, Groups A - D | |
IECEx approval | IECEx FMG 11.0010X | |
Approved for | Ex ia IIC T6/T5 Ga Ex nA IIC T6/T5 Gc Ex ia IIIC T95°C Da | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 , IEC 60079-15:2010 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | quasi flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 12.15 mm | |
Actual operating distance | 13.5 ... 16.5 mm | |
Reduction factor rAl | 0.33 | |
Reduction factor rCu | 0.28 | |
Reduction factor r304 | 0.81 | |
Nominal ratings | ||
Operating voltage | 20 ... 253 V | |
Switching frequency | 0 ... 20 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
Operating current | 5 ... 200 mA | |
Off-state current | 0 ... 1.7 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector 1/2"-20 UN , 3-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP67 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Connectable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | aluminum | |
Mass | approx. 1000 g | |
Dimensions | 91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting versions see type code | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection, temperature class | ![]() ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009 | |
International approvals | ||
IECEx approval | BVS 11.0061 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-MKF8 |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Connectable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting versions see type code | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-MKF8 |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 15 mm | |
Installation | quasi flush | |
Output polarity | AC | |
Assured operating distance | 0 ... 12.15 mm | |
Actual operating distance | 13.5 ... 16.5 mm | |
Reduction factor rAl | 0.33 | |
Reduction factor rCu | 0.28 | |
Reduction factor r304 | 0.81 | |
Output type | 2-wire | |
Nominal ratings | ||
Operating voltage | 20 ... 253 V | |
Switching frequency | 0 ... 20 Hz | |
Hysteresis | typ. 5 % | |
Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
Operating current | 5 ... 200 mA | |
Off-state current | 0 ... 1.7 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector 7/8 inch-16 UN , 3-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Connectable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting versions see type code | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection, temperature class | ![]() | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009 | |
International approvals | ||
IECEx approval | BVS 11.0061 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-MKF8 |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.