General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1500 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 17 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1060 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.14 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | key switch | |
Color | black / silver | |
Contact configuration | 1x NO / 1x NC | |
Switching configuration | 2 position changeover with left OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Lockable | yes | |
Labeling | 0 - I | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 136 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | key switch | |
Color | black / silver | |
Contact configuration | 1x NO / 1x NC | |
Switching configuration | 2 position changeover with left OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Lockable | yes | |
Labeling | 0 - I | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 136 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1x M25 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 1500 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 15 mA | |
Constant magnetic field | 200 mT | |
Alternating magnetic field | 200 mT | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 990 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | Brass, PTFE coated | |
Sensing face | PPS | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | key switch | |
Color | black / silver | |
Contact configuration | 2x NO | |
Switching configuration | 2 position changeover with left OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Lockable | yes | |
Labeling | 0 - I | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 136 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | key switch | |
Color | black / silver | |
Contact configuration | 2x NO | |
Switching configuration | 3 position changeover with center OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage - engage | |
Lockable | yes | |
Labeling | l - 0 - ll | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 136 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 1500 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 15 mA | |
Switching state indicator | Multihole-LED, yellow | |
Mag. Field strength, AC fields | 200 mT | |
Mag. Field strength, DC fields | 200 mT | |
Functional safety related parameters | ||
MTTFd | 990 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Brass, PTFE coated | |
Sensing face | PPS | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | LED indicator | |
Color | green | |
Rated operating voltage | 20 ... 250 V AC | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 123 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | LED indicator | |
Color | red | |
Rated operating voltage | 20 ... 250 V AC | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 123 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 1500 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 15 mA | |
Operating voltage indicator | LED, green | |
Switching state indicator | Multihole-LED, yellow | |
Mag. Field strength, AC fields | 200 mT | |
Mag. Field strength, DC fields | 200 mT | |
Functional safety related parameters | ||
MTTFd | 2430 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Brass, PTFE coated | |
Sensing face | Ceramic coated | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, small | |
Color | black | |
Contact configuration | 2x NO | |
Switching configuration | 2 position changeover with left OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Labeling | 0 - I | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, small | |
Color | black | |
Contact configuration | 1x NO / 1x NC | |
Switching configuration | 2 position changeover | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Labeling | I - II | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm | |
Reduction factor rAl | 0.35 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Reduction factor rBrass | 0.4 | |
Nominal ratings | ||
Operating voltage | 10 ... 65 V | |
Switching frequency | 0 ... 1200 Hz | |
Hysteresis | 0.02 ... 0.44 | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Overload resistance | yes | |
Wire breakage protection | yes | |
Inductive overvoltage protection | yes | |
Surge suppression | yes | |
Ripple | 10 % | |
Voltage drop | &le 2.5 V | |
Repeat accuracy | 0.1 mm | |
Operating current | 0 ... 300 mA | |
Off-state current | 0.01 mA | |
No-load supply current | &le 10 mA | |
Switching state indicator | Multihole-LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1510 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | 4-pin, M12 x 1 connector | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
Mass | 20 g |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, small | |
Color | black | |
Contact configuration | 1x NO / 1x NC | |
Switching configuration | 2 position changeover | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Labeling | I - II | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1x M25 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 1.52 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1500 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 17 mA | |
Switching state indicator | Multihole-LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1060 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
EAC conformity | TR CU 020/2011 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, small | |
Color | black | |
Contact configuration | 2x NO | |
Switching configuration | 3 position changeover with center OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage - engage | |
Labeling | l - 0 - ll | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | pushbutton | |
Color | green | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Labeling | I | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 116 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1500 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 17 mA | |
Switching state indicator | Multihole-LED, yellow | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | 4-pin, M12 x 1 connector | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | pushbutton | |
Color | red | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Labeling | 0 | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 116 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, large | |
Color | black | |
Shroud | yes | |
Contact configuration | 2x NO | |
Switching configuration | 2 position changeover with left OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Lockable | padlockable in '0' | |
Labeling | 0 - l | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, large | |
Color | black | |
Shroud | yes | |
Contact configuration | 1x NO / 1x NC | |
Switching configuration | 2 position changeover | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Labeling | I - II | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, large | |
Color | black | |
Shroud | yes | |
Contact configuration | 1x NO / 1x NC | |
Switching configuration | 2 position changeover | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage | |
Labeling | I - II | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 131 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1x M25 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1500 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 17 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 990 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, large | |
Color | black | |
Shroud | yes | |
Contact configuration | 2x NO | |
Switching configuration | 3 position changeover with center OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage - engage | |
Lockable | padlockable in '0' | |
Labeling | l - 0 - ll | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 130 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | control switch, large | |
Color | black | |
Shroud | yes | |
Contact configuration | 2x NO | |
Switching configuration | 3 position changeover with center OFF | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | engage - engage - engage | |
Lockable | padlockable in '0' | |
Labeling | l - 0 - ll | |
Mechanical specifications | ||
Height | 110 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 130 mm with operators (C1) 125 mm with mounting brackets (K) | |
Fixing holes distance, height | 110 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1x M25 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 1.5 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1500 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 17 mA | |
Switching state indicator | Multihole-LED, yellow | |
Functional safety related parameters | ||
MTTFd | 990 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | pushbutton | |
Color | green | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Labeling | I | |
Function 2 | mushroom button | |
Color | red | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | latching , key release | |
Lockable | yes | |
Mechanical specifications | ||
Height | 220 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 133 mm with operators (C1) 235 mm with mounting brackets (K) | |
Fixing holes distance, height | 220 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 3 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | pushbutton | |
Color | green | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Labeling | I | |
Function 2 | mushroom button | |
Color | red | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Operator action | latching , key release | |
Lockable | yes | |
Mechanical specifications | ||
Height | 220 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 133 mm with operators (C1) 235 mm with mounting brackets (K) | |
Fixing holes distance, height | 220 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1x M25 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 3 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
General specifications | ||
---|---|---|
Switching function | complementary | |
Output type | NPN | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.25 | |
Reduction factor rCu | 0.15 | |
Reduction factor r304 | 0.66 | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 1000 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
No-load supply current | &le 20 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 3220 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery |
Electrical specifications | ||
---|---|---|
Operating voltage | 250 V max. | |
Operating current | 16 A max. | |
Terminal capacity | 2.5 mm2 | |
Function | pushbutton | |
Color | green | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Labeling | I | |
Function 2 | pushbutton | |
Color | red | |
Contact configuration | 1x NO / 1x NC | |
Usage category | AC12 - 12 ... 250 V AC - 16 A AC15 - 12 ... 250 V AC - 10 A DC13 - 12 ... 110 V DC - 1 A DC13 - 12 ... 24 V DC - 1A | |
Number of poles | 2 | |
Labeling | O | |
Mechanical specifications | ||
Height | 220 mm (A) | |
Width | 110 mm (B) | |
Depth | 101 mm (C) | |
External dimension | 116 mm with operators (C1) 235 mm with mounting brackets (K) | |
Fixing holes distance, height | 220 mm (G) | |
Fixing holes distance, width | 78 mm (H) | |
Enclosure cover | fully detachable | |
Cover fixing | M6 stainless steel socket cap head screws | |
Fixing holes diameter | 7 mm (J) | |
Degree of protection | IP66 | |
Cable entry | ||
Number of cable entries | 1 x M20 in face A fitted with polyamide Ex e stopping plug 1x M20 in face B fitted with polyamide Ex e cable gland | |
Defined entry area | face A and face B | |
Material | ||
Enclosure | carbon loaded, antistatic glass fiber reinforced polyester (GRP) | |
Finish | inherent color black | |
Seal | one piece solid silicone rubber | |
Mass | 3 kg | |
Mounting | 7 mm slots moulded into base | |
Grounding | 2.5 mm2 grounding terminal | |
Ambient conditions | ||
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) @ T4 -40 ... 40 °C (-40 ... 104 °F) @ T6 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | CML 16 ATEX 3009 X | |
Marking | ![]() Ex db eb mb IIC T* Gb Ex tb IIIC T** °C Db T6/T80 °C @ Ta +40 °C T4/T130 °C @ Ta +55 °C | |
International approvals | ||
IECEx approval | IECEx CML 16.0008X | |
EAC approval | TC RU C-DE.GB06.B.00567 | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | Engraved traffolyte tag label Engraved AISI 316L stainless steel tag label Color in-fill stainless steel tag label |
Компания Zipstore.ru поставляет оптом и в розницу запчасти Pepperl+Fuchs.
В каталоге сайта представлено 13440 запчастей Pepperl+Fuchs. Также вы можете приобрести опции и аксессуары для расширения функциональных возможностей, транспортировки и эксплуатации оборудования. Запчасти в каталоге могут иметь полное название, каталожный номер, фотографию, краткое описание, а также модели принтеров, с которыми они совместимы.
Для оформления заказа вы можете воспользоваться одним из следующих способов:
Мы осуществляем поставки запчастей Pepperl+Fuchs во все города России, а также в Республику Беларусь, Казахстан и другие страны СНГ.
Продажа осуществляется за наличный и безналичный расчет. На сайте указаны розничные цены в рублях и долларах, с учетом НДС. Чтобы узнать оптовые цены на запчасти Pepperl+Fuchs, нужно отправить запрос по электронной почте. Подробнее о способах доставки и оплаты можно узнать в разделе сайта «Оплата и доставка». В разделе «%Скидки и акции» Вы можете найти наиболее выгодные предложения по продаже запчастей, а также сезонные скидки и акции.
При возникновении вопросов по обслуживанию, эксплуатации, ремонту Pepperl+Fuchs, Вы можете проконсультироваться со специалистами на форуме сайта.