Каталожный номер: 230441
| General specifications |
|---|
| Switching function | complementary |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1530 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 184374
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1640 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.5 mm2 |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 230442
| General specifications |
|---|
| Switching function | complementary |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1530 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 184375
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1530 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.5 mm2 |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 184378
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | NPN |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1530 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 184377
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1640 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.5 mm2 |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 237162
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Rated insulation voltage | 60 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1640 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 6 m |
| Core cross-section | 0.5 mm2 |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 184380
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.45 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.55 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 1400 Hz |
| Hysteresis | typ. 5% |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2.5 V |
| Operating current | 0 ... 250 mA |
| Off-state current | 0 ... 0.01 mA typ. 0.1 µA at 25 °C |
| No-load supply current | &le 15 mA |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1640 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| Protection class | II |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 800 V |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Tightening torque, fastening screws | Threading M3 max: 1.1 Nm |
Каталожный номер: 214773
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 600 Hz |
| Hysteresis | typ. 8 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 500 bar (7252 psi) |
| Peak pressure | 1000 bar (14504 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 728 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Ceramic |
| Housing diameter | 12 mm |
| Degree of protection | IP68 |
| Mass | 27 g |
Каталожный номер: 123392
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 600 Hz |
| Hysteresis | typ. 8 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 500 bar (7252 psi) |
| Peak pressure | 1000 bar (14504 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 728 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Ceramic |
| Housing diameter | 12 mm |
| Degree of protection | IP68 |
| Mass | 27 g |
Каталожный номер: 123393
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 600 Hz |
| Hysteresis | typ. 8 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 500 bar (7252 psi) |
| Peak pressure | 1000 bar (14504 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 728 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Ceramic |
| Housing diameter | 12 mm |
| Degree of protection | IP68 |
| Mass | 31 g |
Каталожный номер: 123394
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 600 Hz |
| Hysteresis | typ. 8 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 500 bar (7252 psi) |
| Peak pressure | 1000 bar (14504 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 728 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Ceramic |
| Housing diameter | 12 mm |
| Degree of protection | IP68 |
| Mass | 42 g |
Каталожный номер: 123395
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 600 Hz |
| Hysteresis | typ. 8 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 2 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 500 bar (7252 psi) |
| Peak pressure | 1000 bar (14504 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 728 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Ceramic |
| Housing diameter | 12 mm |
| Degree of protection | IP68 |
| Mass | 42 g |
Каталожный номер: 125502
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.21 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 88006
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.22 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V DC |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 350 bar (5076.4 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 1240 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -35 ... 80 °C (-31 ... 176 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Epoxy (black) |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
Каталожный номер: 88007
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.22 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.5 |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 60 V |
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 200 mA |
| No-load supply current | &le 10 mA |
| Limit data |
|---|
| Operating pressure | 350 bar (5076.4 psi) |
| Functional safety related parameters |
|---|
| MTTFd | 1240 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -35 ... 80 °C (-31 ... 176 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | Epoxy (black) |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
Каталожный номер: 128866
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 10 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 128865
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 128863
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | Multihole-LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 6.5 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
Каталожный номер: 128870
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 10 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 3G 1D |
Каталожный номер: 128869
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 5 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
| Cable | |
| Bending radius | > 10 x cable diameter |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 3G 1D |
Каталожный номер: 232898
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , black 30 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 295008
| General specifications |
|---|
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | NAMUR |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 3590 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m Protective hose L = 30 cm |
| Connection assembly | Protective hose : stainless steel 1.4301 / AISI 304 screwed connection : MS58 nickel-plated |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
Каталожный номер: 295009
| General specifications |
|---|
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | NAMUR |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 3590 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m Protective hose L = 40 cm |
| Connection assembly | Protective hose : stainless steel 1.4301 / AISI 304 screwed connection : MS58 nickel-plated |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
Каталожный номер: 295010
| General specifications |
|---|
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | NAMUR |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) |
| Switching frequency | 0 ... 2000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Functional safety related parameters |
|---|
| MTTFd | 3590 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Approvals and certificates |
|---|
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m Protective hose L = 50 cm |
| Connection assembly | Protective hose : stainless steel 1.4301 / AISI 304 screwed connection : MS58 nickel-plated |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
Каталожный номер: 180206
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | NAMUR |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.215 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.19 |
| Reduction factor r304 | 0.65 |
| Nominal ratings |
|---|
| Nominal voltage | 8 V |
| Switching frequency | 0 ... 5000 Hz |
| Hysteresis | 1 ... 10 typ. 3 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Current consumption | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | &le 1 mA |
| Switching state indicator | Multihole-LED, yellow |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
| General information |
|---|
| Use in the hazardous area | see instruction manuals |
| Category | 1G 2G 1D |
Каталожный номер: 126095
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.21 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.16 |
| Reduction factor r304 | 0.64 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2950 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 126098
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.21 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.16 |
| Reduction factor r304 | 0.64 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.14 mm2 |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 126088
| General specifications |
|---|
| Switching function | Normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.21 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.16 |
| Reduction factor r304 | 0.64 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 2950 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Каталожный номер: 126099
| General specifications |
|---|
| Switching function | Normally closed (NC) |
| Output type | Two-wire |
| Rated operating distance | 1.5 mm |
| Installation | flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 1.21 mm |
| Actual operating distance | 1.35 ... 1.65 mm typ. |
| Reduction factor rAl | 0.22 |
| Reduction factor rCu | 0.16 |
| Reduction factor r304 | 0.64 |
| Nominal ratings |
|---|
| Operating voltage | 5 ... 60 V |
| Switching frequency | 0 ... 1200 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | pulsing |
| Voltage drop | &le 5 V |
| Operating current | 2 ... 100 mA |
| Lowest operating current | 2 mA |
| Off-state current | 0 ... 0.5 mA typ. |
| Switching state indicator | LED, yellow |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M8 x 1 , 3-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | LCP |
| Housing diameter | 8 mm |
| Degree of protection | IP67 |
Pepperl+Fuchs — ориентир в промышленной автоматизации и взрывозащите
Pepperl+Fuchs — немецкий бренд с более чем 75-летней историей инженерного превосходства. Основанная в 1945 году в Мангейме, компания стала пионером бесконтактных датчиков и одним из мировых лидеров в области intrinsically safe решений для опасных сред. Сегодня Pepperl+Fuchs объединяет два направления — Factory Automation и Process Automation — предлагая датчики, интерфейсную электронику, системы взрывозащиты и HMI, которые повышают надежность, безопасность и эффективность производственных процессов.
Ключевые преимущества Pepperl+Fuchs
- Инженерное качество: стабильные измерения, высокая повторяемость и минимальные ошибки в жестких условиях эксплуатации.
- Безопасность и соответствие: решения с сертификатами ATEX, IECEx, UL и соответствием SIL/PL для критически важных применений.
- Готовность к IIoT: поддержка IO-Link, AS-Interface, промышленного Ethernet и современных протоколов для прозрачности данных и предиктивного обслуживания.
- Устойчивость к среде: широкий температурный диапазон, стойкость к вибрациям, влаге, пыли и химическим воздействиям (включая IP-защиту).
- Совместимость и интеграция: бесшовная работа с ведущими ПЛК и системами управления, унифицированные интерфейсы и аксессуары.
- Глобальная поддержка: доступность документации, сервисной сети и запасных частей для надежной долгосрочной эксплуатации.
Продуктовые направления
- Датчики и системы распознавания: индуктивные, емкостные, магнитные, ультразвуковые и фотоэлектрические датчики; датчики расстояния, уплотнения контуров и позиционирования; энкодеры, 2D-ридеры и сканеры кода, RFID (HF/UHF), а также интеллектуальные решения с IO-Link. Для задач объемного контроля — лидарные сенсоры и визион-системы.
- Интерфейсная техника и искробезопасность: гальванические изоляторы и барьеры (K-System, H-System, Zener), модули ввода/вывода, защита от перенапряжений, источники питания и диагностика шины FieldConnex для Foundation Fieldbus и PROFIBUS PA.
- Оборудование для взрывоопасных зон: корпуса и клеммные коробки Ex e/Ex d из нержавеющей стали, алюминия и GRP; станции управления; системы продувки и наддува Bebco EPS; HMI и операторские панели для зон 1/21 и 2/22; мобильные устройства ecom для безопасной работы на площадках.
- Связь и подключение: мастера и хабы IO-Link, компоненты AS-Interface, распределительные блоки, коннекторы и кабельная арматура для быстрого и чистого монтажа.
- Функциональная безопасность: датчики и модули с подтвержденными уровнями SIL/PL, включая решения AS-i Safety at Work для защиты персонала и оборудования.
Области применения
Решения Pepperl+Fuchs используются в автомобильной промышленности, машиностроении, пищевой и фармацевтической отраслях, логистике и складской автоматизации, а также в нефтегазовом, химическом и горнодобывающем секторах, на объектах энергетики, водоснабжения и очистки стоков. Бренд одинаково эффективен для модернизации отдельных участков и для комплексной автоматизации линий и установок.
Почему это выгодно
- Минимум простоев: надежная диагностика и предсказуемое обслуживание снижают незапланированные остановки.
- Точность и качество: стабильные показания повышают выпуск и уменьшают брак.
- Масштабируемость: широкий ассортимент позволяет развивать систему без смены платформы.
- Долгий жизненный цикл: продуманная номенклатура и преемственность серий упрощают поставки и ремонт.
- Полный комплект: от датчика и интерфейсных модулей до взрывозащищенных корпусов и операторских панелей.
Как выбрать решение Pepperl+Fuchs
Определите среду (включая наличие взрывоопасных зон), необходимые интерфейсы и уровень безопасности, диапазон измерений и точность, а также условия монтажа. Сверьте каталожные номера с требуемыми сертификатами и аксессуарами. При сложных задачах стоит привлечь инженера для подбора комплекта устройств с учетом специфики технологического процесса.
Pepperl+Fuchs — это инвестиция в надежность, безопасность и предсказуемые результаты. Выбирайте оригинальные решения бренда для уверенной работы оборудования сегодня и готовности к задачам завтрашнего дня.