Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm | |
| Reduction factor rAl | 0.38 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.8 | |
| Reduction factor rBrass | 0.45 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | 0.01 ... 0.33 mm | |
| Reverse polarity protection | yes | |
| Short-circuit protection | yes | |
| Overload resistance | yes | |
| Wire breakage protection | yes | |
| Inductive overvoltage protection | yes | |
| Surge suppression | yes | |
| Ripple | 10 % | |
| Voltage drop | &le 2.5 V | |
| Repeat accuracy | 0.05 mm | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0.01 mA | |
| No-load supply current | &le 7 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2090 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M8 x 1 , 3-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 8 mm | |
| Degree of protection | IP67 | |
| Mass | 7 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1528 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1528 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1528 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M8 x 1 , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1750 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1750 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M8 x 1 , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1528 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1528 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M8 x 1 , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| Off-state current TU =40 °C, switching element off | &le | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1750 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1500 Hz | |
| Hysteresis | typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1750 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M8 x 1 , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| Mass | 13.5 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 500 mm | |
| Core cross-section | 0.08 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 100 mm | |
| Core cross-section | 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 500 mm | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | no | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 3910 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Solder connection PVC , 500 mm | |
| Core cross-section | 0.08 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 3910 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 100 mm | |
| Core cross-section | 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 3910 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 500 mm | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NPN | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 500 mm | |
| Core cross-section | 0.08 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M12 x 1 , 3-pin with PVC cable L = 160 mm ± 5 mm | |
| Core cross-section | 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 100 mm | |
| Core cross-section | 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 500 mm | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 4830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , L = 2 m | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 3910 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 500 mm | |
| Core cross-section | 0.08 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 3910 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 100 mm | |
| Core cross-section | 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Functional safety related parameters | ||
| MTTFd | 3910 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , L = 500 mm | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.215 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 1200 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 15 mA | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 3 x 0.09 mm2 | |
| Housing material | PA | |
| Sensing face | PA | |
| Housing diameter | ||
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 1 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 0.81 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.29 | |
| Reduction factor r304 | 0.76 | |
| Reduction factor rBrass | 0.46 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 700 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.055 mm2 | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PC | |
| Housing diameter | 3 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 1 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 0.81 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.29 | |
| Reduction factor r304 | 0.76 | |
| Reduction factor rBrass | 0.46 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 700 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.1 mA typ. at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M8 x 1 , 3-pin with PVC cable 300 mm | |
| Core cross-section | 0.055 mm2 | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PC | |
| Housing diameter | 3 mm | |
| Degree of protection | IP67 | |
Товаров: 0