Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Описание оборудования | ||
---|---|---|
Electronic cam-operated switch group |
Описание оборудования | ||
---|---|---|
DVI to CAT5 KVM kit |
Описание оборудования | ||
---|---|---|
DVI to fiber KVM kit |
Описание оборудования | ||
---|---|---|
VGA to CAT5 KVM kit |
Описание оборудования | ||
---|---|---|
Raritan Dominion KVM Switch |
Supply | ||
---|---|---|
Connection | backplane bus | |
Rated voltage | 12 V DC , only in connection with the power supplies FB92** | |
Power consumption | 0.65 W | |
Internal bus | ||
Connection | backplane bus | |
Interface | manufacturer-specific bus to standard com unit | |
Output | ||
Number of channels | 2 | |
Connection | wire ends 1 (white), 2 (brown), 3 (green), 4 (yellow), 5 (grey), 6 (pink) | |
Minimum load | 1 V , 1 mA | |
Relay | ||
Switching voltage | 24 V DC / 230 V AC | |
Switching current | 1 A DC / AC resistive load | |
Switching power | 30 W , 230 VA resistive load | |
Electrical life | 0.5 Mio. cycles | |
Response time | 20 ms (depending on bus cycle time) | |
Contact Material | AgPd gold plated | |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication | |
Indicators/settings | ||
LED indicator | LED green: supply LED yellow: signal (status) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1 | |
Low voltage | ||
Directive 2006/95/EC | EN 61010-1 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Relative humidity | 95 % non-condensing | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 50 m/s2, number of shock directions 6, number of shocks per direction 100 | |
Vibration resistance | frequency range 5 ... 500 Hz, amplitude 5 ... 13.2 Hz ± 1.5 mm, 13.2 ... 100 Hz 1g, sweep rate 1 octave/min, duration 10 sweeps 5 Hz - 100 Hz - 5 Hz | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description | |
Connection | wire ends or shielded cable tail wiring connection: separately covered Ex e terminals required | |
Mass | approx. 350 g | |
Dimensions | 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | PTB 97 ATEX 1074 U | |
Group, category, type of protection | II 2 G Ex d IIC Gb | |
Galvanic isolation | ||
Output/power supply, internal bus | safe electrical isolation acc. to EN 61010-1 | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 | |
International approvals | ||
ATEX approval | BVS 11 ATEX E 093X | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
Supply | ||
---|---|---|
Connection | backplane bus | |
Rated voltage | 12 V DC , only in connection with the power supplies FB92** | |
Power consumption | 1.2 W | |
Internal bus | ||
Connection | backplane bus | |
Interface | manufacturer-specific bus to standard com unit | |
Output | ||
Number of channels | 4 | |
Connection | wire ends 1/9 (white), 2/10 (brown), 3/11 (green), 4/12 (yellow), 5/13 (grey), 6/14 (pink), 7/15 (blue), 8/16 (red) | |
Minimum load | 1 V , 1 mA | |
Relay | ||
Switching voltage | DC: 30 V , AC: 230 V | |
Switching current | 1 A DC / AC resistive load | |
Switching power | 30 W , AC: 250 VA | |
Electrical life | 0.1 mio. cycles | |
Response time | 20 ms (depending on bus cycle time) | |
Contact Material | AgPd gold plated | |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication | |
Indicators/settings | ||
LED indicator | LED green: supply LED red: communication fault | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1 | |
Low voltage | ||
Directive 2006/95/EC | EN 61010-1 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Relative humidity | 95 % non-condensing | |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 50 m/s2, number of shock directions 6, number of shocks per direction 100 | |
Vibration resistance | frequency range 5 ... 500 Hz, amplitude 5 ... 13.2 Hz ± 1.5 mm, 13.2 ... 100 Hz 1g, sweep rate 1 octave/min, duration 10 sweeps 5 Hz - 100 Hz - 5 Hz | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description | |
Connection | wire ends or shielded cable tail wiring connection: separately covered Ex e terminals required | |
Mass | approx. 750 g | |
Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | PTB 97 ATEX 1074 U | |
Group, category, type of protection | II 2 G Ex d IIC Gb | |
Galvanic isolation | ||
Output/power supply, internal bus | safe electrical isolation acc. to EN 61010-1 | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 | |
International approvals | ||
ATEX approval | BVS 11 ATEX E 093X | |
EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
Marine approval | ||
Lloyd Register | 15/20021 | |
DNV GL Marine | TAA0000034 | |
American Bureau of Shipping | T1450280/UN | |
Bureau Veritas Marine | 22449/B0 BV |
Описание оборудования | ||
---|---|---|
AS-Interface EMERGENCY STOP button |
Описание оборудования | ||
---|---|---|
AS-Interface EMERGENCY STOP button |
Описание оборудования | ||
---|---|---|
AS-Interface EMERGENCY STOP button |
Описание оборудования | ||
---|---|---|
AS-Interface EMERGENCY STOP button |
Описание оборудования | ||
---|---|---|
Emergency stop button |
Supply | ||
---|---|---|
Rated voltage | 7 ... 32 V DC | |
Rated current | < 1 mA , max. 25 mA | |
Electrical specifications | ||
Output rated operating current | 3.2 ... 25 mA | |
Supply | loop power for field devices voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V | |
Input | ||
Connection | - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | up to 8 HART field devices (depending on installation) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013+A11:2013 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300 328 V1.8.1:2012 EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012-09 | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Material | Aluminum alloy with polyurethane enamel paint | |
Mass | 460 g | |
Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) | |
Data for application in connection with hazardous areas | ||
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
Supply | ||
---|---|---|
Rated voltage | 7 ... 30 V DC | |
Rated current | < 1 mA , max. 25 mA | |
Electrical specifications | ||
Output rated operating current | 3.2 ... 25 mA | |
Supply | loop power for field devices voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V | |
Input | ||
Connection | - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | up to 8 HART field devices (depending on installation) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013+A11:2013 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300 328 V1.8.1:2012 EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012-09 | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Material | Aluminum alloy with polyurethane enamel paint | |
Mass | 460 g | |
Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | FM 11 ATEX 0019 X | |
Marking | II 1 G Ex ia IIC T6/T5 Ga II 1 D Ex ia IIIC T95 °C Da | |
Certificate | FM 11 ATEX 0068 X | |
Marking | II 3 G Ex nA IIC T6/T5 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | CoC3040786(C) | |
Approved for | Class I, Zone 0, (A)Ex ia IIC T6/T5 Ga Class I, Zone 2, (A)Ex nA IIC T6/T5 Gc Class I, Zone 20, (A)Ex ia IIIC T95°C Da Class I, Division 1, Groups A - D Class II, Division 1, Groups E - G Class III Class I, Division 2, Groups A - D | |
IECEx approval | IECEx FMG 11.0010X | |
Approved for | Ex ia IIC T6/T5 Ga Ex nA IIC T6/T5 Gc Ex ia IIIC T95°C Da | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 , IEC 60079-15:2010 |
Supply | ||
---|---|---|
Rated voltage | 7 ... 32 V DC | |
Rated current | < 1 mA , max. 25 mA | |
Electrical specifications | ||
Output rated operating current | 3.2 ... 25 mA | |
Supply | loop power for field devices voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V | |
Input | ||
Connection | - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | up to 8 HART field devices (depending on installation) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013+A11:2013 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300 328 V1.8.1:2012 EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012-09 | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Material | Aluminum alloy with polyurethane enamel paint | |
Mass | 460 g | |
Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | FM 12 ATEX 0021 X | |
Marking | II 2 G Ex db IIC T6/T5 Gb II 2 D Ex tb IIIC T95°C Db | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | Coc3041762(C) | |
Approved for | Class I, Zone 1, (A)Ex db IIC T6/T5 Gb Class I, Zone 21, (A)Ex tb IIIC T95°C Db Class I, Division 1, Groups A - D Class II, Division 1, Groups E - G Class III | |
IECEx approval | IECEx FMG 12.0005X | |
Approved for | Ex db IIC T6/T5 Gb Ex tb IIIC T95°C Db | |
Standards | IEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013 |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Connectable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | aluminum | |
Mass | approx. 1000 g | |
Dimensions | 91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting versions see type code | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection, temperature class | II 2 G Ex ia IIC T4 Gb II 2 D Ex tb [ia] IIIC T70°C Db IP6x | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009 | |
International approvals | ||
IECEx approval | BVS 11.0061 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-MKF8 |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Connectable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting versions see type code | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-MKF8 |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Connectable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 99/5/EC | ETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting versions see type code | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | BVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection, temperature class | II 2 G Ex ia IIC T4 Gb | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009 | |
International approvals | ||
IECEx approval | BVS 11.0061 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-MKF8 |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.3, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
RoHs | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | Aluminum | |
Mass | approx. 1000 g | |
Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BVS 17 ATEX E 029 | |
Marking | II 2G Ex ia IIC T4/T3 Gb II 2D Ex tb [ia] IIIC T70°C Db | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0435 | |
IECEx approval | ||
IECEx certificate | IECEX BVS 17.0023 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.3, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
RoHs | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) |
Supply | ||
---|---|---|
Rated voltage | 7.2 V DC , battery operated | |
Electrical specifications | ||
Output rated operating current | 4 ... 20 mA | |
Supply | loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V | |
Input | ||
Suitable field devices | usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode | |
Connection | terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode | |
Current | 4 ... 20 mA | |
HART communication | ||
Protocol | HART 7.3, backward compatible | |
Number of devices | - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode | |
Transfer rate | 1200 Bit/s | |
Parameters | primary/secondary master, preambles, retries and short address scan ranges | |
Output | ||
Output variables | PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables | |
Transfer characteristics | ||
Accuracy | current input: 0.125 % of measuring range | |
Influence of ambient temperature | current input: 5 µA/K | |
Indicators/settings | ||
Parameter assignment | - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013, CLASS A | |
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 | |
RoHs | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Vibration resistance | 20 ... 2000 Hz, 0,01 g2/Hz | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60 | |
Mechanical specifications | ||
Degree of protection | IP66 | |
Material | plastic | |
Mass | approx. 750 g | |
Dimensions | 92 x 89.5 x 92.8 mm (without cable glands and antenna) | |
Mounting | mounting on field device , panel or pole mounting | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BVS 17 ATEX E 029 | |
Marking | II 2G Ex ia IIC T4/T3 Gb | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014 | |
International approvals | ||
IECEx approval | ||
IECEx certificate | IECEX BVS 17.0023 | |
Accessories | ||
Designation | battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20) |
Описание оборудования | ||
---|---|---|
24 V DC power supply |
Описание оборудования | ||
---|---|---|
cover sheet |
Описание оборудования | ||
---|---|---|
Empty housing for Evaluation unit SB4 |
Описание оборудования | ||
---|---|---|
Empty housing for Evaluation unit SB4 |
Описание оборудования | ||
---|---|---|
Empty housing for Evaluation unit SB4 |
Описание оборудования | ||
---|---|---|
Empty housing for Evaluation unit SB4 |
Описание оборудования | ||
---|---|---|
Empty housing for Evaluation unit SB4 |
Товаров: 0
На сумму: 0