Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| General specifications | ||
|---|---|---|
| Signal type | Analog output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 7+, 8- | |
| Rated voltage | 20 ... 35 V DC | |
| Ripple | within the supply tolerance | |
| Rated current | &le 50 mA | |
| Power dissipation | 1.2 W | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 9+, 10-, 11+ | |
| Voltage drop | approx. 4 V at 20 mA | |
| Limit | Input current: approx. &le40 mA input voltage: &le 35 V | |
| Transmission range | 0 ... 20 mA | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Current | 0 ... 20 mA | |
| Load | max. 850 &Omega | |
| Voltage | 17 V at 20 mA | |
| Transfer characteristics | ||
| Accuracy | 0.1 % | |
| Rise time | < 10 ms | |
| Indicators/settings | ||
| Display elements | LED | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Insulation coordination | EN 50178 | |
| Galvanic isolation | EN 50178 | |
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 100 g | |
| Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) , housing type B1 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| Certificate | TÜV 99 ATEX 1499 X | |
| Marking | II 3G Ex nA II T4 | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
| Описание оборудования | ||
|---|---|---|
| 2-channel | ||
| Описание оборудования | ||
|---|---|---|
| 1-channel | ||
| Описание оборудования | ||
|---|---|---|
| 2-channel | ||
| General specifications | ||
|---|---|---|
| Signal type | Analog output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 9+, 10- | |
| Rated voltage | 19 ... 30 V DC | |
| Ripple | &le 10 % | |
| Rated current | &le 30 mA | |
| Power dissipation | &le 600 mW | |
| Power consumption | &le 700 mW | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 5-, 6+ | |
| Input signal | 4 ... 20 mA limited to approx. 30 mA | |
| Voltage drop | depending on switch configuration open loop voltage of the control system < 23 V: approx. 6 V at 20 mA open loop voltage of the control system < 27 V: approx. 10 V at 20 mA | |
| Input resistance | > 100 k&Omega, with field wiring open | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Current | 4 ... 20 mA | |
| Load | 0 ... 650 &Omega | |
| Voltage | &ge 13 V at 20 mA | |
| Ripple | 20 mV rms | |
| Transfer characteristics | ||
| Accuracy | 0.1 % | |
| Deviation | at 20 °C (68 °F), 0/4 ... 20 mA &le ± 0.1 % incl. non-linearity and hysteresis | |
| Frequency range | bandwidth at 0.5 Vss signal 0 ... 3 kHz (-3 dB) | |
| Rise time | 10 to 90 % &le 100 ms | |
| Indicators/settings | ||
| Display elements | LED | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 100 g | |
| Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General specifications | ||
|---|---|---|
| Signal type | Analog output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 9+, 10- | |
| Rated voltage | 19 ... 30 V DC | |
| Ripple | &le 10 % | |
| Rated current | &le 30 mA | |
| Power dissipation | &le 600 mW | |
| Power consumption | &le 700 mW | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 5-, 6+ | |
| Input signal | 4 ... 20 mA limited to approx. 30 mA | |
| Voltage drop | depending on switch configuration open loop voltage of the control system < 23 V: approx. 6 V at 20 mA open loop voltage of the control system < 27 V: approx. 10 V at 20 mA | |
| Input resistance | > 100 k&Omega, with field wiring open | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Current | 4 ... 20 mA | |
| Load | 0 ... 650 &Omega | |
| Voltage | &ge 13 V at 20 mA | |
| Ripple | 20 mV rms | |
| Transfer characteristics | ||
| Accuracy | 0.1 % | |
| Deviation | at 20 °C (68 °F), 0/4 ... 20 mA &le ± 0.1 % incl. non-linearity and hysteresis | |
| Frequency range | bandwidth at 0.5 Vss signal 0 ... 3 kHz (-3 dB) | |
| Rise time | 10 to 90 % &le 100 ms | |
| Indicators/settings | ||
| Display elements | LED | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IP20 according to EN 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | spring terminals | |
| Mass | approx. 100 g | |
| Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General specifications | ||
|---|---|---|
| Signal type | Analog output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 35 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | 0.8 W at 20 mA into 10 V (equivalent to 500 &Omega) load | |
| Power consumption | 1 W at 20 mA | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7-, 8+, (9+) | |
| Voltage drop | approx. 4 V or internal resistance 200 &Omega at 20 mA | |
| Input resistance | > 100 k&Omega, when wiring resistance in the field > 16 V (equivalent to 800 &Omega at 20 mA) | |
| Current | 4 ... 20 mA limited to approx. 25 mA | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- | |
| Current | 4 ... 20 mA | |
| Load | 100 ... 700 &Omega | |
| Voltage | &ge 14 V at 20 mA | |
| Transfer characteristics | ||
| Accuracy | 0.05 % | |
| Rise time | < 100 µs , 10 ... 90 % step change | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General specifications | ||
|---|---|---|
| Signal type | Analog output | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 35 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | 1.4 W at 20 mA into 10 V (equivalent to 500 &Omega) load | |
| Power consumption | 1.8 W at 20 mA | |
| Input | ||
| Connection side | control side | |
| Connection | terminals 7-, 8+, (9+) 10-, 11+, (12+) | |
| Voltage drop | approx. 4 V or internal resistance 200 &Omega at 20 mA | |
| Input resistance | > 100 k&Omega, when wiring resistance in the field > 16 V (equivalent to 800 &Omega at 20 mA) | |
| Current | 4 ... 20 mA limited to approx. 25 mA | |
| Output | ||
| Connection side | field side | |
| Connection | terminals 1+, 2- 4+, 5- | |
| Current | 4 ... 20 mA | |
| Load | 100 ... 700 &Omega | |
| Voltage | &ge 14 V at 20 mA | |
| Transfer characteristics | ||
| Accuracy | 0.05 % | |
| Rise time | < 100 µs , 10 ... 90 % step change | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Товаров: 0