| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 50 mA | |
| Time delay before availability | &le 2.5 s | |
| Interface | ||
| Interface type | CANopen | |
| Device profile | CiA410, Ver. 1.2 | |
| Data output code | binary code | |
| Transfer rate | 125 kBit/s , 250 kBit/s , 500 kBit/s , 1 MBit/s , programmable | |
| Node ID | 1 ... 127 , programmable | |
| Termination | external | |
| Cycle time | &ge 20 ms | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 1 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 650 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Status indicator | LED, yellow | |
| Error indicator | LED, red | |
| Electrical specifications | ||
| Operating voltage | 5 ... 30 V DC | |
| No-load supply current | &le 100 mA | |
| Power consumption | &le 0.7 W | |
| Interface | ||
| Interface type | J1939 | |
| Data output code | binary code | |
| Transfer rate | 10 ... 1000 kBit/s , programmable | |
| Node ID | 0 ... 253 , programmable | |
| Termination | external | |
| Cycle time | programmable | |
| SLOT Range | 0 ... 359.99 ° | |
| SLOT Offset | 0 ° | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector 5-pin, M12 x 1 socket internal bridged | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 128 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 current output 4 ... 20 mA | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 5 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 current output 4 ... 20 mA | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 7 m, PUR cable 5 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 current output 4 ... 20 mA | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8.5 m , PUR cable , 5 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 current output 4 ... 20 mA | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 390 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 voltage output 0 ... 5 V | |
| Load resistor | &ge 1 k&Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 5 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 1-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 20 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 390 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 1 voltage output 0 ... 5 V | |
| Load resistor | &ge 1 k&Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 304 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 25 m PUR cable 7 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 304 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 7 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 304 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 390 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | LED, yellow | |
| Electrical specifications | ||
| Operating voltage | 18 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Analog output | ||
| Output type | 2 voltage outputs 0 ... 10 V (one output for each axis) | |
| Load resistor | &ge 1 k&Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 5 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 390 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | LED, yellow | |
| Electrical specifications | ||
| Operating voltage | 18 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Analog output | ||
| Output type | 2 voltage outputs 0 ... 10 V (one output for each axis) | |
| Load resistor | &ge 1 k&Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 50 mA | |
| Time delay before availability | &le 2.5 s | |
| Interface | ||
| Interface type | CANopen | |
| Device profile | CiA410, Ver. 1.2 | |
| Data output code | binary code | |
| Transfer rate | 10 ... 1000 kBit/s , programmable | |
| Node ID | 1 ... 127 , programmable | |
| Termination | external | |
| Cycle time | &ge 20 ms | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 1 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -15 ... 15 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.01 ° | |
| Repeat accuracy | &le ± 0.02 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 650 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Status indicator | LED, yellow | |
| Error indicator | LED, red | |
| Electrical specifications | ||
| Operating voltage | 5 ... 30 V DC | |
| No-load supply current | &le 100 mA | |
| Power consumption | &le 0.7 W | |
| Interface | ||
| Interface type | J1939 | |
| Data output code | binary code | |
| Transfer rate | 10 ... 1000 kBit/s , programmable | |
| Node ID | 0 ... 253 , programmable | |
| Termination | external | |
| Cycle time | programmable | |
| SLOT Range | -15 ... 15 ° | |
| SLOT Offset | 180 ° | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector 5-pin, M12 x 1 socket internal bridged | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 128 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -30 ... 30 ° | |
| Absolute accuracy | &le ± 0.2 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.02 ° | |
| Repeat accuracy | &le ± 0.04 ° | |
| Temperature influence | &le 0.004 °/K | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -60 ... 60 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 650 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Status indicator | LED, yellow | |
| Error indicator | LED, red | |
| Electrical specifications | ||
| Operating voltage | 5 ... 30 V DC | |
| No-load supply current | &le 100 mA | |
| Power consumption | &le 0.7 W | |
| Interface | ||
| Interface type | J1939 | |
| Data output code | binary code | |
| Transfer rate | 10 ... 1000 kBit/s , programmable | |
| Node ID | 0 ... 253 , programmable | |
| Termination | external | |
| Cycle time | programmable | |
| SLOT Range | -60 ... 60 ° | |
| SLOT Offset | 180 ° | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector 5-pin, M12 x 1 socket internal bridged | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 128 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | -85 ... 85 ° | |
| Absolute accuracy | &le ± 0.5 ° [-60°...+60°] | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.004 °/K | |
| Functional safety related parameters | ||
| MTTFd | 650 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Status indicator | LED, yellow | |
| Error indicator | LED, red | |
| Electrical specifications | ||
| Operating voltage | 5 ... 30 V DC | |
| No-load supply current | &le 100 mA | |
| Power consumption | &le 0.7 W | |
| Interface | ||
| Interface type | J1939 | |
| Data output code | binary code | |
| Transfer rate | 10 ... 1000 kBit/s , programmable | |
| Node ID | 0 ... 253 , programmable | |
| Termination | external | |
| Cycle time | programmable | |
| SLOT Range | -85 ... 85 ° | |
| SLOT Offset | 180 ° | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 0.6 m, PUR cable 5 x 0.5 mm2 Deutsch connector DTM04-6P | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 30 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 7 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 current outputs 4 ... 20 mA (one output for each axis) | |
| Load resistor | 0 ... 200 &Omega at UB = 10 ... 18 V 0 ... 500 &Omega at UB = 18 ... 30 V | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 390 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 voltage outputs 0 ... 5 V (one output for each axis) | |
| Load resistor | &ge 1 k&Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5 m, PUR cable 7 x 0.5 mm2 | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 390 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 25 mA | |
| Time delay before availability | &le 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Voltage drop | &le 3 V | |
| Analog output | ||
| Output type | 2 voltage outputs 0 ... 5 V (one output for each axis) | |
| Load resistor | &ge 1 k&Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | &le 50 mA | |
| Time delay before availability | &le 2.5 s | |
| Interface | ||
| Interface type | CANopen | |
| Device profile | CiA410, Ver. 1.2 | |
| Data output code | binary code | |
| Transfer rate | 125 kBit/s , 250 kBit/s , 500 kBit/s , 1 MBit/s , programmable | |
| Node ID | 1 ... 127 , programmable | |
| Termination | external | |
| Cycle time | &ge 20 ms | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 1 | |
| Transfer rate | 250 kBit/s | |
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | &le ± 0.5 ° | |
| Response delay | &le 25 ms | |
| Resolution | &le 0.1 ° | |
| Repeat accuracy | &le ± 0.1 ° | |
| Temperature influence | &le 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 650 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Status indicator | LED, yellow | |
| Error indicator | LED, red | |
| Electrical specifications | ||
| Operating voltage | 5 ... 30 V DC | |
| No-load supply current | &le 100 mA | |
| Power consumption | &le 0.7 W | |
| Interface | ||
| Interface type | J1939 | |
| Data output code | binary code | |
| Transfer rate | 10 ... 1000 kBit/s , programmable | |
| Node ID | 0 ... 253 , programmable | |
| Termination | external | |
| Cycle time | programmable | |
| SLOT Range | 0 ... 359.99 ° | |
| SLOT Offset | 0 ° | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector 5-pin, M12 x 1 socket internal bridged | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |
| Factory settings | ||
| Node ID | 128 | |
| Transfer rate | 250 kBit/s | |
| Описание оборудования | ||
|---|---|---|
| Inertial measurement unit 6-axis | ||
| Описание оборудования | ||
|---|---|---|
| 1 axis acceleration sensor | ||
| Описание оборудования | ||
|---|---|---|
| 2 axis acceleration sensor | ||
| Описание оборудования | ||
|---|---|---|
| Inertial measurement unit 6-axis | ||
| Описание оборудования | ||
|---|---|---|
| Inertial measurement unit 6-axis | ||
Товаров: 0
На сумму: 0