Каталожный номер: 226336
| Описание оборудования |
|---|
| AS-Interface |
Каталожный номер: 226317
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 20 mm |
| Installation | flush |
| Assured operating distance | 0 ... 16.2 mm |
| Reduction factor rAl | 0.33 |
| Reduction factor rCu | 0.31 |
| Reduction factor r304 | 0.74 |
| Reduction factor rBrass | 0.41 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP69K |
| Mass | 130 g |
Каталожный номер: 226318
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 20 mm |
| Installation | flush |
| Assured operating distance | 0 ... 16.2 mm |
| Reduction factor rAl | 0.33 |
| Reduction factor rCu | 0.31 |
| Reduction factor r304 | 0.74 |
| Reduction factor rBrass | 0.41 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Error indicator | LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP69K |
| Mass | 130 g |
Каталожный номер: 226315
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 20 mm |
| Installation | flush |
| Assured operating distance | 0 ... 16.2 mm |
| Actual operating distance | 18 ... 22 mm typ. 20 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.35 |
| Reduction factor r304 | 0.85 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Error indicator | LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | screw terminals |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
| Core cross-section | up to 2.5 mm2 |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 |
| Housing material | PA/metal with epoxy powder coating |
| Sensing face | PBT |
| Housing diameter | |
| Degree of protection | IP68 / IP69K |
Каталожный номер: 190763
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 6 mm |
| Installation | flush |
| Assured operating distance | 0 ... 4.86 mm |
| Reduction factor rAl | 0.28 |
| Reduction factor rCu | 0.25 |
| Reduction factor r304 | 0.75 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | &ge 500 (P3=0), |
| Hysteresis | typ. 5 % |
| Operating current | 20 mA |
| Functional safety related parameters |
|---|
| MTTFd | 1873 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Indicators/operating means |
|---|
| LED POWER | AS-Interface voltage LED green |
| LED IN | switching state (input) LED yellow |
| LED OUT | Dual LED yellow/red yellow: switching state red: error mode |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Mass | 90 g |
Каталожный номер: 190764
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 6 mm |
| Installation | flush |
| Assured operating distance | 0 ... 4.86 mm |
| Reduction factor rAl | 0.28 |
| Reduction factor rCu | 0.25 |
| Reduction factor r304 | 0.75 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | &ge 500 (P3=0), &ge 100 (P3=1) |
| Hysteresis | typ. 5 % |
| Operating current | 20 mA |
| Functional safety related parameters |
|---|
| MTTFd | 532 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Indicators/operating means |
|---|
| LED POWER | AS-Interface voltage LED green |
| LED IN | switching state (input) LED yellow |
| LED OUT | Dual LED yellow/red yellow: switching state red: error mode |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | cable PVC , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | PBT |
| Degree of protection | IP67 |
| Mass | 90 g |
Каталожный номер: 226335
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 8 mm |
| Installation | flush |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.5 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.0 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 200 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 926 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | 4-pin, M12 x 1 connector |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
Каталожный номер: 226334
| Описание оборудования |
|---|
| AS-Interface |
Каталожный номер: 244541
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2.5 mm |
| Installation | for non-flush mounting |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.05 mm |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | all connections |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 605 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | screw terminal , M20 x 1.5 cable gland |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid |
| Connection (valve side) | 4-pin, M12 x 1 socket |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use |
| Degree of protection | IP66 / IP67 / IP69K |
| Tightening torque, housing screws | &le 2 Nm |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm |
| Tightening torque, stopping plug | 1 Nm |
Каталожный номер: 260495
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 2.5 mm |
| Installation | for non-flush mounting |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.05 mm |
| Output type | 2x 2-wire |
| Nominal ratings |
|---|
| Operating voltage | 6 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 0.5 mm |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | no |
| Voltage drop | &le 6 V |
| Operating current | 4 ... 100 mA |
| Off-state current | 100 ... 200 µA typ. 160 µA |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 684 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | screw terminal , M20 x 1.5 cable gland |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid |
| Connection (valve side) | 4-pin, M12 x 1 socket |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use |
| Degree of protection | IP66 / IP67 / IP69K |
| Tightening torque, housing screws | &le 2 Nm |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm |
| Tightening torque, stopping plug | 1 Nm |
Каталожный номер: 244545
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | PNP |
| Rated operating distance | 2.5 mm |
| Installation | for non-flush mounting |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.05 mm |
| Output type | 4-wire |
| Nominal ratings |
|---|
| Operating voltage | 10 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | all connections |
| Short-circuit protection | pulsing |
| Voltage drop | &le 3 V |
| Operating current | 0 ... 100 mA |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 605 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | screw terminal , M20 x 1.5 cable gland |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid |
| Connection (valve side) | 4-pin, M12 x 1 socket |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use |
| Degree of protection | IP66 / IP67 / IP69K |
| Tightening torque, housing screws | &le 2 Nm |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm |
| Tightening torque, stopping plug | 1 Nm |
Каталожный номер: 260497
| General specifications |
|---|
| Switching function | 2 x normally open (NO) |
| Output type | Two-wire |
| Rated operating distance | 2.5 mm |
| Installation | for non-flush mounting |
| Output polarity | DC |
| Assured operating distance | 0 ... 2.05 mm |
| Output type | 2x 2-wire |
| Nominal ratings |
|---|
| Operating voltage | 6 ... 30 V |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 0.5 mm |
| Reverse polarity protection | reverse polarity tolerant |
| Short-circuit protection | no |
| Voltage drop | &le 6 V |
| Operating current | 4 ... 100 mA |
| Off-state current | 100 ... 200 µA typ. 160 µA |
| Switching state indicator | LED, yellow |
| Valve status indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 684 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| EAC conformity | TR CU 020/2011 |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
|---|
| Ambient temperature | -40 ... 75 °C (-40 ... 167 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection (system side) | screw terminal , M20 x 1.5 cable gland |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid |
| Connection (valve side) | 4-pin, M12 x 1 socket |
| Housing material | rugged, translucent polycarbonate (PC) optimised for outdoor use |
| Degree of protection | IP66 / IP67 / IP69K |
| Tightening torque, housing screws | &le 2 Nm |
| Tightening torque, cable gland | M20 x 1.5 max. 4 Nm M12 x 1 max. 3 Nm |
| Tightening torque, stopping plug | 1 Nm |
Каталожный номер: 226319
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 30 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 24.3 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.75 |
| Reduction factor rBrass | 0.38 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP67 |
| Mass | 210 g |
Каталожный номер: 226320
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.75 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 50 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 40 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Housing diameter | |
| Degree of protection | IP69K |
Каталожный номер: 226321
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.75 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 50 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Error indicator | LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP69K |
| Mass | 210 g |
Каталожный номер: 226316
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 32.4 mm |
| Actual operating distance | 36 ... 44 mm typ. 40 mm |
| Reduction factor rAl | 0.5 |
| Reduction factor rCu | 0.45 |
| Reduction factor r304 | 0.85 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
| Error indicator | LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | screw terminals |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
| Core cross-section | up to 2.5 mm2 |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 |
| Housing material | PA/metal with epoxy powder coating |
| Sensing face | PBT |
| Housing diameter | |
| Degree of protection | IP68 / IP69K |
Каталожный номер: 226332
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 2 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.62 mm |
| Actual operating distance | 1.8 ... 2.2 mm typ. |
| Reduction factor rAl | 0.23 |
| Reduction factor rCu | 0.21 |
| Reduction factor r304 | 0.7 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 10 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 226330
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 4 mm |
| Installation | flush |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm |
| Reduction factor rAl | 0.23 |
| Reduction factor rCu | 0.21 |
| Reduction factor r304 | 0.7 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Voltage drop at IL | |
| Voltage drop IL = 20 mA, switching element on | 3.4 ... 5 V typ. 4.3 V |
| No-load supply current | &le 25 mA |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 226328
| Описание оборудования |
|---|
| AS-Interface |
Каталожный номер: 226333
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 5 mm |
| Installation | flush |
| Assured operating distance | 0 ... 4.05 mm |
| Actual operating distance | 4.5 ... 5.5 mm typ. 5 mm |
| Reduction factor rAl | 0.2 |
| Reduction factor rCu | 0.15 |
| Reduction factor r304 | 0.62 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Voltage drop at IL | |
| Voltage drop IL = 20 mA, switching element on | 3.4 ... 5 V typ. 4.3 V |
| No-load supply current | &le 25 mA |
| Operating voltage indicator | dual-LED, green |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 926 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Electromagnetic compatibility | EN 50295:1999-10
|
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 18 mm |
| Degree of protection | IP67 |
Каталожный номер: 226323
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 226324
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 226322
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 226325
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 226326
| Описание оборудования |
|---|
| Valve positioner and valve control module |
Каталожный номер: 226331
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.36 |
| Reduction factor r304 | 0.74 |
| Slave type | Standard slave |
| AS-Interface specification | V2.1 |
| Required master specification | &ge V2.0 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Voltage drop at IL | |
| Voltage drop IL = 20 mA, switching element on | 3.4 ... 5 V typ. 4.3 V |
| No-load supply current | &le 25 mA |
| Alternating magnetic field | 100 mT |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 226329
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm |
| Reduction factor rAl | 0.37 |
| Reduction factor rCu | 0.36 |
| Reduction factor r304 | 0.74 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 500 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | &le 25 mA |
| Alternating magnetic field | 100 mT |
| Switching state indicator | dual-LED, yellow |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 2140 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
Каталожный номер: 230829
| General specifications |
|---|
| Switching function | Normally open/closed (NO/NC) programmable |
| Output type | AS-Interface |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 6.48 mm |
| Actual operating distance | 7.2 ... 8.8 mm typ. 8 mm |
| Reduction factor rAl | 0.42 |
| Reduction factor rCu | 0.4 |
| Reduction factor r304 | 0.72 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | &ge V2.1 |
| Output type | 2-wire |
| Nominal ratings |
|---|
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 100 Hz |
| Hysteresis | 1 ... 15 typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Voltage drop at IL | |
| Voltage drop IL = 20 mA, switching element on | 3.4 ... 5 V typ. 4.3 V |
| Operating voltage indicator | dual-LED, green |
| Switching state indicator | dual-LED, yellow/red |
| Error indicator | dual-LED, red |
| Functional safety related parameters |
|---|
| MTTFd | 926 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Compliance with standards and directives |
|---|
| Standard conformity | |
| Electromagnetic compatibility | EN 50295:1999-10
|
| Approvals and certificates |
|---|
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated &le36 V |
| Ambient conditions |
|---|
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F)
|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
|---|
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
Каталожный номер: 240229
| Описание оборудования |
|---|
| Protective cap for mechanical protection and for use in applications in conditions where moisture is present. |
Каталожный номер: T37280
| General specifications |
|---|
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute encoder |
| Electrical specifications |
|---|
| Operating voltage | 29.5 ... 31.6 V DC |
| No-load supply current | max. starting current 155 mA , operating current max. 85 mA |
| Linearity | ± 1 LSB |
| Output code | programmable, Gray code, binary code |
| Code course (counting direction) | programmable, cw ascending (clockwise rotation, code course ascending) cw descending (clockwise rotation, code course descending) |
| Interface |
|---|
| Interface type | AS-Interface |
| Resolution | |
| Overall resolution | See table, max. 16 Bit |
| Transfer rate | max. 0.167 MBit/s |
| Standard conformity | AS-Interface |
| Connection |
|---|
| Connector | type V1, M12, 4-pin |
| Standard conformity |
|---|
| Degree of protection | DIN EN 60529, IP65 |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 11 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz |
| Ambient conditions |
|---|
| Operating temperature | -20 ... 70 °C (-4 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
|---|
| Material | housing: powder coated aluminum flange: aluminum shaft: stainless steel |
| Mass | approx. 360 g |
| Rotational speed | max. 6000 min -1 |
| Moment of inertia | 30 gcm2 |
| Starting torque | &le 2 Ncm |
| Tightening torque, fastening screws | max. 1.8 Nm |
| Shaft load | |
| Angle offset | 1 ° |
| Axial offset | max. 1 mm |
Купить Датчики + Поворотные энкодеры Pepperl+Fuchs по оптовым ценам