| Описание оборудования | ||
|---|---|---|
| AC Power Supply | ||
| Описание оборудования | ||
|---|---|---|
| DC Power Supply | ||
| Описание оборудования | ||
|---|---|---|
| DC Power Supply | ||
| General specifications | ||
|---|---|---|
| No-load protection | yes | |
| RoHs | conform | |
| Supply | ||
| Rated voltage | 100 ... 240 VAC +/- 10%, 50 - 60 Hz wide-range power supply | |
| Output | ||
| Output rated operating current | 0 ... 5 A, (7,5 A current limitation) | |
| Output voltage | 24 V DC ± 3% over the entire input voltage range | |
| Efficiency | 88 % (typ.) | |
| Holdup time | > 50 ms over the entire input voltage range | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2004/108/EC | EN 55022 Class B, Line harminic distortion acc. to EN 61000-3-2, EN 61000-6-1/2 | |
| Low voltage | EN60950 | |
| Explosion protection | ||
| Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
| Ambient conditions | ||
| Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
| Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP66 | |
| Mass | approx. 40 kg | |
| Dimensions | 459 mm x 301.5 mm x 226 mm | |
| Dimensions with wall mount bracket | 489 mm x 412 mm x 255 mm | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
| Group, category, type of protection | II 2G Ex eq IIC T4 II 2D Ex tD A21 IP64 T95°C | |
| International approvals | ||
| IECEx approval | IECEx BVS 08.0024 | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 28 V DC | |
| Output | ||
| Output voltage | rated voltage | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2004/108/EC | EN55022 Class B, EN61000-6-1/-2 | |
| Low voltage | EN60950 | |
| Explosion protection | ||
| Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
| Ambient conditions | ||
| Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
| Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP66 | |
| Mass | approx. 40 kg | |
| Dimensions | 459 mm x 301.5 mm x 226 mm | |
| Dimensions with wall mount bracket | 489 mm x 412 mm x 255 mm | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
| Group, category, type of protection | II 2G Ex eq IIC T4 II 2D Ex tD A21 IP64 T95°C | |
| International approvals | ||
| IECEx approval | IECEx BVS 08.0024 | |
| Steckplätze | ||
|---|---|---|
| Buskoppler | 2 | |
| E/A-Module | >12, je nach Typ | |
| Versorgung | ||
| Anschluss | Anschluss an Ex-e-Klemmen über Backplane | |
| Sicherheitst. Maximalspannung Um | 60 V DC (SELV/PELV) | |
| Eingangsspannungsbereich | 18 ... 32 V DC (SELV/PELV) | |
| Verlustleistung | ca. 15 % der entnommenen Leistung | |
| Leistungsaufnahme | max. 45 W Parallelschaltung mit weiterem FB9206D (autom. Leistungsaufteilung) | |
| Einschaltstrom | 1,5 A (10 ms) | |
| Ausgang | ||
| Spannung | 5,4 V DC +/- 5% , 12 V DC + 4/- 2% | |
| Leistung | P5V &le 5,4 W, P12V &le 39 W - P5V | |
| Anzeigen/Einstellungen | ||
| LED-Anzeige | LED grün: AUS bei Verlust von 24V oder 12V oder 5V | |
| Richtlinienkonformität | ||
| Elektromagnetische Verträglichkeit | ||
| Richtlinie 2014/30/EU | EN 61326-1 | |
| Konformität | ||
| Elektromagnetische Verträglichkeit | NE 21 | |
| Schutzart | IEC 60529 | |
| Umgebungsbedingungen | ||
| Umgebungstemperatur | -20 ... 60 °C (-4 ... 140 °F) | |
| Lagertemperatur | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative Luftfeuchtigkeit | 95 % nicht kondensierend | |
| Schockfestigkeit | Schockform I, Schockdauer 11 ms, Schockamplitude 15 g, Anzahl der Schocks 18 | |
| Schwingungsfestigkeit | Frequenzbereich 10 ... 150 Hz Übergangsfrequenz: 57,56 Hz, Amplitude/Beschleunigung ± 0,075 mm/1 g 10 Zyklen Frequenzbereich 5 ... 100 Hz Übergangsfrequenz: 13,2 Hz Amplitude/Beschleunigung ± 1 mm/0,7 g 90 Minuten bei jeder Resonanz | |
| Schadgas | beständig in Umgebungsbedingungen nach ISA S71.04-1985, Severity Level G3 | |
| Mechanische Daten | ||
| Schutzart | IP20 (Modul) , separates Gehäuse entsprechend Systembeschreibung erforderlich | |
| Masse | ca. 820 g | |
| Abmessungen | 57 x 107 x 132 mm | |
| Daten für den Einsatz in Verbindung mit explosionsgefährdeten Bereichen | ||
| EU-Baumusterprüfbescheinigung | PTB 97 ATEX 1074 U | |
| Kennzeichnung | II 2 G Ex d IIC Gb | |
| Galvanische Trennung | ||
| Ausgang/Versorgung | EN 60950-1 (sicherheitstechnisch < 60 V, externe Stromversorgung SELV/PELV) | |
| Richtlinienkonformität | ||
| Richtlinie 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 | |
| Internationale Zulassungen | ||
| ATEX-Zulassung | PTB 97 ATEX 1075 | |
| EAC-Zulassung | Russland: RU C-IT.MIII06.B.00129 | |
| Schiffsbau-Zulassung | ||
| Lloyd Register | 15/20021 | |
| DNV GL Marine | TAA0000034 | |
| American Bureau of Shipping | T1450280/UN | |
| Bureau Veritas Marine | 22449/B0 BV | |
| Steckplätze | ||
|---|---|---|
| Buskoppler | 2 | |
| E/A-Module | >12, je nach Typ | |
| Versorgung | ||
| Anschluss | Anschluss an Ex-e-Klemmen über Backplane | |
| Sicherheitst. Maximalspannung Um | 253 V AC | |
| Eingangsspannungsbereich | 90 ... 253 V AC | |
| Verlustleistung | ca. 18 % der entnommenen Leistung | |
| Leistungsaufnahme | max. 47 W Parallelschaltung mit weiterem FB9215B2 (autom. Leistungsaufteilung) | |
| Einschaltstrom (< 2 ms) | 30 A max. (115 V AC) 50 A max. (230 V AC) | |
| Eingang | ||
| Eingangsfrequenz | 50 ... 60 Hz | |
| Ausgang | ||
| Spannung | 5,4 V DC +/- 5% , 12 V DC +/- 3% | |
| Leistung | P5V &le 5,4 W, P12V &le 39 W - P5V | |
| Anzeigen/Einstellungen | ||
| LED-Anzeige | LED grün: AUS bei Verlust der Netzspannung oder internen Spannungen (12 V, 5,4 V) | |
| Richtlinienkonformität | ||
| Elektromagnetische Verträglichkeit | ||
| Richtlinie 2014/30/EU | EN 61326-1:2013 | |
| Konformität | ||
| Elektromagnetische Verträglichkeit | NE 21:2007 | |
| Schutzart | IEC 60529:2000 | |
| Umgebungsbedingungen | ||
| Umgebungstemperatur | -20 ... 60 °C (-4 ... 140 °F) | |
| Lagertemperatur | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative Luftfeuchtigkeit | 95 % nicht kondensierend | |
| Schockfestigkeit | Schockform I, Schockdauer 11 ms, Schockamplitude 15 g, Anzahl der Schocks 18 | |
| Schwingungsfestigkeit | Frequenzbereich 10 ... 150 Hz Übergangsfrequenz: 57,56 Hz, Amplitude/Beschleunigung ± 0,075 mm/1 g 10 Zyklen Frequenzbereich 5 ... 100 Hz Übergangsfrequenz: 13,2 Hz Amplitude/Beschleunigung ± 1 mm/0,7 g 90 Minuten bei jeder Resonanz | |
| Schadgas | beständig in Umgebungsbedingungen nach ISA S71.04-1985, Severity Level G3 | |
| Mechanische Daten | ||
| Schutzart | IP20 (Modul) , separates Gehäuse entsprechend Systembeschreibung erforderlich | |
| Masse | ca. 890 g | |
| Abmessungen | 57 x 107 x 132 mm | |
| Daten für den Einsatz in Verbindung mit explosionsgefährdeten Bereichen | ||
| EU-Baumusterprüfbescheinigung | PTB 97 ATEX 1074 U | |
| Kennzeichnung | II 2 G Ex d IIC Gb | |
| Galvanische Trennung | ||
| Ausgang/Versorgung | EN 60950-1 (sicherheitstechnisch < 60 V, externe Stromversorgung SELV/PELV) | |
| Richtlinienkonformität | ||
| Richtlinie 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 | |
| Internationale Zulassungen | ||
| EAC-Zulassung | Russland: RU C-IT.MIII06.B.00129 | |
| Schiffsbau-Zulassung | ||
| Lloyd Register | 15/20021 | |
| American Bureau of Shipping | T1450280/UN | |
| Bureau Veritas Marine | 22449/B0 BV | |
| Steckplätze | ||
|---|---|---|
| Buskoppler | 2 | |
| E/A-Module | >12, je nach Typ | |
| Versorgung | ||
| Sicherheitst. Maximalspannung Um | 60 V DC (SELV/PELV) | |
| Eingangsspannungsbereich | 18 ... 32 V DC (SELV/PELV) | |
| Verlustleistung | ca. 15 % der entnommenen Leistung | |
| Leistungsaufnahme | max. 30 W für Zone-2-Anwendungen max. 45 W für Anwendungen im sicheren Bereich Parallelschaltung mit anderen LB9006C (autom. Leistungsaufteilung) | |
| Einschaltstrom | 1,5 A (10 ms) | |
| Ausgang | ||
| Spannung | 5,4 V DC +/- 5% , 12 V DC + 4/- 2% | |
| Leistung | P5V &le 5,4 W, P12V &le 25 W - P5V für Zone-2-Anwendungen P5V &le 5,4 W, P12V &le 39 W - P5V für Anwendungen im sicheren Bereich | |
| Anzeigen/Einstellungen | ||
| LED-Anzeige | Power-LED (P) grün: erlischt bei Ausfall der 24 V oder 12 V oder 5 V | |
| Richtlinienkonformität | ||
| Elektromagnetische Verträglichkeit | ||
| Richtlinie 2014/30/EU | EN 61326-1 | |
| Konformität | ||
| Elektromagnetische Verträglichkeit | NE 21 | |
| Schutzart | IEC 60529 | |
| Umgebungsbedingungen | ||
| Umgebungstemperatur | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (nicht-Ex) | |
| Lagertemperatur | -25 ... 85 °C (-13 ... 185 °F) | |
| Schockfestigkeit | Schockform I, Schockdauer 11 ms, Schockamplitude 15 g, Anzahl der Schocks 18 | |
| Schwingungsfestigkeit | Frequenzbereich 10 ... 150 Hz Übergangsfrequenz: 57,56 Hz, Amplitude/Beschleunigung ± 0,075 mm/1 g 10 Zyklen Frequenzbereich 5 ... 100 Hz Übergangsfrequenz: 13,2 Hz Amplitude/Beschleunigung ± 1 mm/0,7 g 90 Minuten bei jeder Resonanz | |
| Schadgas | beständig in Umgebungsbedingungen nach ISA S71.04-1985, Severity Level G3 | |
| Mechanische Daten | ||
| Schutzart | IP20 (Modul) , auf Backplane montiert | |
| Masse | ca. 220 g | |
| Abmessungen | 32,5 x 100 x 102 mm | |
| Daten für den Einsatz in Verbindung mit explosionsgefährdeten Bereichen | ||
| Zertifikat | PF 08 CERT 1234 X | |
| Kennzeichnung | II 3 G Ex nA IIC T4 Gc | |
| Galvanische Trennung | ||
| Ausgang/Versorgung, interner Bus | EN 60950-1 (Sicherheitsanforderung: < 60 V, externe Versorgung SELV/PELV) | |
| Richtlinienkonformität | ||
| Richtlinie 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 | |
| Internationale Zulassungen | ||
| UL-Zulassung | E106378 | |
| IECEx-Zulassung | BVS 09.0037X | |
| Zugelassen für | Ex nA IIC T4 Gc | |
| Schiffsbau-Zulassung | ||
| Lloyd Register | 15/20021 | |
| DNV GL Marine | TAA0000034 | |
| Bureau Veritas Marine | 22449/B0 BV | |
| Supply | ||
|---|---|---|
| Connection | wired to Ex e terminals | |
| Rated voltage | 95 ... 230 V AC | |
| Power consumption | max. 45 VA | |
| Inrush current | 3.4 A (10 ms) | |
| Input | ||
| Input frequency | 50 ... 60 Hz | |
| Output | ||
| Current | 1.2 A | |
| Voltage | 24 V DC +/- 3% (Connectors 5, 12) 23 V DC +/- 3% decoupled via diode (Connectors 5, 13) | |
| Indicators/settings | ||
| LED indicator | LED green: supply | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1 | |
| Low voltage | ||
| Directive 2006/95/EC | EN 61010-1 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 95 % non-condensing | |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
| Vibration resistance | frequency range 10 ... 150 Hz transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g 10 cycles frequency range 5 ... 100 Hz transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g 90 minutes at each resonance | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
| Mechanical specifications | ||
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description | |
| Mass | approx. 890 g | |
| Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | PTB 97 ATEX 1074 U | |
| Marking | II 2 G Ex d IIC Gb | |
| Galvanic isolation | ||
| Output/power supply | EN 60950-1 (safety requirement < 60 V) | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 | |
| International approvals | ||
| ATEX approval | PTB 97 ATEX 1075 | |
| EAC approval | Russia: RU C-IT.MIII06.B.00129 | |
| Marine approval | ||
| Lloyd Register | 15/20021 | |
| DNV GL Marine | TAA0000034 | |
| American Bureau of Shipping | T1450280/UN | |
| Bureau Veritas Marine | 22449/B0 BV | |
| General specifications | ||
|---|---|---|
| Type | Power supply | |
| Описание оборудования | ||
|---|---|---|
| PS3500 N+1 Diagonostic Module for use with series PS3500 3 and 6-position backplanes. | ||
| Описание оборудования | ||
|---|---|---|
| 3 position N+1 Power Supply Backplane for use with PS2500 and PS3500 N+1 Power Supplies. | ||
| Описание оборудования | ||
|---|---|---|
| 6 position N+1 Power Supply Backplane for use with PS2500 and PS3500 N+1 Power Supplies. | ||
| Описание оборудования | ||
|---|---|---|
| PS3500 N+1 Power Supply for use with series PS2500 and PS3500 3 and 6-position backplanes. | ||
| General specifications | ||
|---|---|---|
| No-load protection | yes | |
| RoHs | conform | |
| Supply | ||
| Rated voltage | 100 ... 240 VAC +/- 10%, 50 - 60 Hz wide-range power supply | |
| Output | ||
| Output rated operating current | 0 ... 5 A, (7,5 A current limitation) | |
| Output voltage | 24 V DC ± 3% over the entire input voltage range | |
| Efficiency | 88 % (typ.) | |
| Holdup time | > 50 ms over the entire input voltage range | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2004/108/EC | EN 55022 Class B, Line harminic distortion acc. to EN 61000-3-2, EN 61000-6-1/2 | |
| Low voltage | EN60950 | |
| Explosion protection | ||
| Directive 94/9/EC | EN60079-0:2006, IEC60079-5:2007_Ed.3, EN60079-7:2007, EN61241-0:2006, EN61241-1:2004 | |
| Ambient conditions | ||
| Operating temperature | -20 ... 50 °C (-4 ... 122 °F) | |
| Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Relative humidity | 85 % , noncondensing | |
| Mechanical specifications | ||
| Degree of protection | IP66 | |
| Mass | approx. 16 kg | |
| Dimensions | 452 mm x 191 mm x 110 mm | |
| Dimensions with wall mount bracket | 469 mm x 223 mm x 144 mm | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | BVS 07 ATEX E 026 | |
| Group, category, type of protection | II 2G Ex eq IIC T4 II 2D Ex tD A21 IP64 T95°C | |
| International approvals | ||
| IECEx approval | IECEx BVS 08.0024 | |
| Описание оборудования | ||
|---|---|---|
| Input 4 mA ... 20 mA Output 4 mA ... 20 mA | ||
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA 2 x Output 0/4 mA ... 20 mA | ||
| Описание оборудования | ||
|---|---|---|
| Input 4 mA ... 20 mA Output 4 mA ... 20 mA | ||
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA Output 0/4 mA ... 20 mA | ||
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA Output 0/4 mA ... 20 mA | ||
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA Output 0/4 mA ... 20 mA | ||
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 18 ... 30 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | &le 1 W at maximium load | |
| Power consumption | &le 1.6 W at maximium load | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1+, 2-, 3 | |
| Input signal | 0/4 ... 20 mA | |
| Available voltage | &ge 16 V at 20 mA terminals 1+, 3 | |
| Output | ||
| Connection side | control side | |
| Connection | terminals 7+, 8-, 9- (sink) terminals 7-, 8+, 9+ (source) see additional information | |
| Load | 0 ... 800 &Omega | |
| Output signal | 4 ... 20 mA (overload > 25 mA) | |
| Ripple | max. 50 µA eff | |
| Transfer characteristics | ||
| Deviation | at 20 °C (68 °F), 0/4 ... 20 mA &le 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage | |
| Frequency range | input to output: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB) output to input: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB) | |
| Settling time | 200 µs | |
| Rise time/fall time | 100 µs | |
| Indicators/settings | ||
| Display elements | LED | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 EN 61326-3-2:2008 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 200 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 3 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 18 ... 30 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | &le 1 W at maximium load | |
| Power consumption | &le 1.7 W at maximium load | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1+, 2-, 3 | |
| Input signal | 0/4 ... 20 mA | |
| Available voltage | &ge 16 V at 20 mA , terminals 1+, 3 | |
| Output | ||
| Connection side | control side | |
| Connection | terminals 7+, 8-, 9- 10+, 11-, 12- (sink) terminals 7-, 8+, 9+ 10-, 11+, 12+ (source) see additional information | |
| Load | 0 ... 600 &Omega | |
| Output signal | 0/4 ... 20 mA (overload > 25 mA) | |
| Ripple | max. 50 µA eff | |
| Transfer characteristics | ||
| Deviation | at 20 °C (68 °F), 0/4 ... 20 mA &le ± 10 µA incl. calibration, linearity, hysteresis, loads and supply voltage fluctuations | |
| Frequency range | input in output: bandwidth with 1 mApp signal 0 ... 7.5 kHz (-3 dB) output in input: band width with 1 Vss signal 0.3 ... 7.5 kHz (-3 dB) | |
| Settling time | 200 µs | |
| Rise time/fall time | 100 µs | |
| Indicators/settings | ||
| Display elements | LED | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 EN 61326-3-2:2008 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| General information | ||
| Note | Both output loads must be connected to ensure complete and correct operation within the technical specification. | |
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA Output 0/4 mA ... 20 mA (current sink) | ||
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA Output 0/1 V ... 5 V | ||
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA Output 0/1 V ... 5 V | ||
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 35 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | 1.4 W | |
| Power consumption | 1.8 W | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1+, 2-, 3 or 5-, 6+ | |
| Input signal | 0/4 ... 20 mA | |
| Voltage drop | &le 2.4 V at 20 mA (terminals 5, 6) | |
| Input resistance | &le 64 &Omega terminals 2-, 3 &le 500 &Omega terminals 1+, 3 (250 &Omega load) | |
| Available voltage | &ge 16 V at 20 mA terminals 1+, 3 | |
| Output | ||
| Connection side | control side | |
| Connection | terminals 7+, 8- 10+, 11- | |
| Output signal | 0/4 ... 20 mA (overload > 25 mA) | |
| Ripple | max. 50 µA rms | |
| External supply (loop) | 11 ... 30 V DC | |
| Transfer characteristics | ||
| Deviation | at 20 °C (68 °F), 0/4 ... 20 mA &le 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage | |
| Frequency range | input to output: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB) output to input: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB) | |
| Settling time | 200 µs | |
| Rise time/fall time | 20 µs | |
| Indicators/settings | ||
| Display elements | LED | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 200 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Описание оборудования | ||
|---|---|---|
| Input 0/4 mA ... 20 mA 2 x Output 0/4 mA ... 20 mA (current sink) | ||
| General specifications | ||
|---|---|---|
| Signal type | Analog input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | Power Rail or terminals 14+, 15- | |
| Rated voltage | 20 ... 35 V DC | |
| Ripple | within the supply tolerance | |
| Power dissipation | 1.9 W | |
| Power consumption | max. 2.8 W | |
| Input | ||
| Connection side | field side | |
| Connection | terminals 1+, 3- 4+, 6- | |
| Input signal | 0/4 ... 20 mA | |
| Available voltage | &ge 16 V at 20 mA, terminals 1+, 3 | |
| Output | ||
| Connection side | control side | |
| Connection | terminals 7+, 8- 10+, 11- | |
| Output signal | 0/4 ... 20 mA (overload > 25 mA) | |
| Ripple | max. 50 µA rms | |
| External supply (loop) | 11 ... 30 V DC | |
| Transfer characteristics | ||
| Deviation | at 20 °C (68 °F), 0/4 ... 20 mA &le 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage | |
| Frequency range | input to output: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB) output to input: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB) | |
| Settling time | 200 µs | |
| Rise time/fall time | 20 µs | |
| Galvanic isolation | ||
| Input/input | basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff | |
| Indicators/settings | ||
| Display elements | LED | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 200 g | |
| Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |