Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Grounding | M6 external/M5 internal grounding point | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 01 ATEX 0023 | |
Group, category, type of protection, temperature class | ![]() ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 01 ATEX 0023 | |
Group, category, type of protection, temperature class | ![]() ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 01 ATEX 0023 | |
Group, category, type of protection, temperature class | ![]() ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 01 ATEX 0023 | |
Group, category, type of protection, temperature class | ![]() ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 01 ATEX 0023 | |
Group, category, type of protection, temperature class | ![]() ![]() | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mechanical specifications | ||
---|---|---|
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Grounding | M5 grounding points | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) (-20 °C (-4 °F)/+40 °C (104 °F)) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 01 ATEX 0023 | |
Group, category, type of protection, temperature class | ![]() ![]() | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66/67 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | Aluminum alloy | |
Glass | thermo-resistant tempered glass | |
Finish | painted grey | |
Mass | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Grounding | M6 grounding points | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
Conformity | ||
Degree of protection | EN 60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Optional accessories | see PDF data sheet |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1000 A max. | |
Mechanical specifications | ||
Degree of protection | IP66 (IP67 with O-ring) | |
Material | ||
Enclosure | Stainless steel | |
Ambient conditions | ||
Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
Group, category, type of protection, temperature class | ![]() Ex d IIC Gb Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Electrical specifications | ||
---|---|---|
Operating voltage | 660 V DC / 1000 V AC max. | |
Operating current | 1600 A max. | |
Mechanical specifications | ||
Enclosure cover | detachable , optional hinges | |
Cover fixing | Stainless steel hexagonal head screws | |
Degree of protection | IP66/67 (IP67 with O-ring) | |
Cable entry | see PDF data sheet | |
Defined entry area | see PDF data sheet | |
Material | ||
Enclosure | AISI 316L stainless steel | |
Glass | thermo-resistant tempered glass | |
Finish | shot peened | |
Mass | see PDF data sheet | |
Mounting | see PDF data sheet | |
Ambient conditions | ||
Ambient temperature | see PDF data sheet | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | ![]() Ex d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
International approvals | ||
IECEx approval | IECEx INE 14.0029X | |
Conformity | ||
Degree of protection | EN60529 | |
General information | ||
Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | powder coated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 180 N | |
Radial | 180 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | powder coated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 180 N | |
Radial | 180 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 12 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | powder coated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 180 N | |
Radial | 180 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 19 N | |
Radial | 44 N | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 19 N | |
Radial | 44 N | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 19 N | |
Radial | 44 N | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 40 E-8 revolutions at 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 20 N | |
Radial | 40 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 40 E-8 revolutions at 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 20 N | |
Radial | 40 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 40 E-8 revolutions at 20/40 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP54 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 150 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 3 Ncm | |
Shaft load | ||
Axial | 20 N | |
Radial | 40 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | stainless steel 1.4404 / AISI 316L | |
Flange | stainless steel 1.4404 / AISI 316L | |
Shaft | Stainless steel 1.4412 / AISI 440B | |
Mass | approx. 350 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 270 N | |
Radial | 270 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | stainless steel 1.4404 / AISI 316L | |
Flange | stainless steel 1.4404 / AISI 316L | |
Shaft | Stainless steel 1.4412 / AISI 440B | |
Mass | approx. 350 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 270 N | |
Radial | 270 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 700 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 10 E+8 revolutions | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
Power consumption | &le 1 W | |
Time delay before availability | < 450 ms | |
Output code | Gray code, binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | SSI | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 16 Bit | |
Overall resolution | up to 32 Bit | |
Transfer rate | 0.1 ... 2 MBit/s | |
Cycle time | < 100 µs | |
Standard conformity | RS 422 | |
Input 1 | ||
Input type | Selection of counting direction (cw/ccw) | |
Signal voltage | ||
High | 4.75 V ... UB (cw descending) | |
Low | 0 ... 2 V or unconnected (cw ascending) | |
Input current | < 6 mA | |
Switch-on delay | < 250 ms | |
Input 2 | ||
Input type | zero-set (PRESET 1) with falling edge | |
Signal voltage | ||
High | 4.75 V ... UB | |
Low | 0 ... 2 V | |
Input current | < 6 mA | |
Connection | ||
Connector | M12 connector, 8-pin | |
Cable | &empty7 mm, 6 x 2 x 0.14 mm2, 1 m (cable length, see order code) | |
Standard conformity | ||
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 300 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | stainless steel 1.4404 / AISI 316L | |
Flange | stainless steel 1.4404 / AISI 316L | |
Shaft | Stainless steel 1.4412 / AISI 440B | |
Mass | approx. 350 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | 30 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 270 N | |
Radial | 270 N |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | CANopen | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | DSP 406 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel , painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 256 a at 40 °C | |
Mission Time (TM) | 12 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Power consumption | approx. 4 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | EtherCAT CoE (CANopen over EtherCAT, according to CiA DS-301 and DS-406 device profile CiA) | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 14 Bit | |
Overall resolution | up to 30 Bit | |
Transfer rate | 10 MBit/s / 100 MBit/s | |
Connection | ||
Connector | Ethernet: 2 sockets M12 x 1, 4-pin, D-coded Supply: 1 plug M12 x 1, 4-pin, A-coded | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP66, IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | Zinc plated steel, painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |
General specifications | ||
---|---|---|
Detection type | magnetic sampling | |
Device type | Absolute encoders | |
Linearity error | &le ± 0.1 ° | |
Functional safety related parameters | ||
MTTFd | 480 a at 40 °C | |
Mission Time (TM) | 20 a | |
L10 | 5 E+8 revolutions at 24/198 N axial/radial shaft load | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED green | Operating mode | |
LED red | wrong baud rate | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC (with galvanic isolation) | |
Power consumption | &le 1.2 W | |
Time delay before availability | < 250 ms | |
Output code | binary code | |
Code course (counting direction) | adjustable | |
Interface | ||
Interface type | J1939 | |
Resolution | ||
Single turn | up to 16 Bit | |
Multiturn | up to 15 Bit | |
Overall resolution | up to 31 Bit | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s | |
Cycle time | &ge 1 ms | |
Standard conformity | ISO 11898 | |
Connection | ||
Connector | M12 connector, 5 pin | |
Cable | &empty6 mm, 4 x 2 x 0.14 mm2 | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 or IP67 | |
Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz | |
Ambient conditions | ||
Operating temperature | cable, flexing: -5 ... 70 °C (-23 ... 158 °F), cable, fixed: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 98 % , no moisture condensation | |
Mechanical specifications | ||
Material | ||
Housing | nickel-plated steel , painted | |
Flange | Aluminum | |
Shaft | Stainless steel | |
Mass | approx. 300 g | |
Rotational speed | max. 12000 min -1 | |
Moment of inertia | 50 gcm2 | |
Starting torque | < 5 Ncm | |
Shaft load | ||
Axial | 24 N | |
Radial | 198 N | |
Angle offset | ± 0.9 ° | |
Axial offset | ± 0.3 mm static | |
Radial offset | ± 0.5 mm static |