Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Описание оборудования | ||
---|---|---|
Batch controller |
Описание оборудования | ||
---|---|---|
Batch controller |
Functional safety related parameters | ||
---|---|---|
MTTFd | 2400 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | digital display | |
Number of digits | 5 | |
Display value | digit height 4 mm | |
Reset | manually | |
Electrical specifications | ||
Operating voltage | 24 V DC | |
Power consumption | 0.6 W | |
Input | ||
Pulse length/pulse interval | 50 ms / 50 ms | |
Counting frequency | 10 Hz | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | flexible leads AWG 22 150 mm long | |
Mass | 62 g | |
Dimensions | 48 mm x 24 mm x 59 mm | |
Mounting | latch fastener | |
Life span | > 50 x 106 pulses |
Functional safety related parameters | ||
---|---|---|
MTTFd | 2400 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | digital display | |
Number of digits | 5 | |
Display value | digit height 4 mm | |
Reset | manually | |
Electrical specifications | ||
Operating voltage | 230 V AC | |
Power consumption | 1.3 VA | |
Input | ||
Pulse length/pulse interval | 50 ms / 50 ms | |
Counting frequency | 10 Hz | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | flexible leads AWG 22 150 mm long | |
Mass | 48 g | |
Dimensions | 48 mm x 24 mm x 59 mm | |
Mounting | latch fastener | |
Life span | > 50 x 106 pulses |
Functional safety related parameters | ||
---|---|---|
MTTFd | 4600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | digital display | |
Number of digits | 7 | |
Display value | digit height 4 mm | |
Electrical specifications | ||
Operating voltage | 24 V DC | |
Power consumption | 0.6 W | |
Input | ||
Pulse length/pulse interval | 50 ms / 50 ms | |
Counting frequency | 10 Hz | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | flexible leads AWG 22 150 mm long | |
Mass | 60 g | |
Dimensions | 48 mm x 24 mm x 54 mm | |
Mounting | latch fastener | |
Life span | > 50 x 106 pulses |
Functional safety related parameters | ||
---|---|---|
MTTFd | 4600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | digital display | |
Number of digits | 7 | |
Display value | digit height 4 mm | |
Electrical specifications | ||
Operating voltage | 230 V AC | |
Power consumption | 1.3 VA | |
Input | ||
Pulse length/pulse interval | 50 ms / 50 ms | |
Counting frequency | 10 Hz | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | flexible leads AWG 22 150 mm long | |
Mass | 50 g | |
Dimensions | 48 mm x 24 mm x 54 mm | |
Mounting | latch fastener | |
Life span | > 50 x 106 pulses |
Functional safety related parameters | ||
---|---|---|
MTTFd | 9300 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | digital display | |
Number of digits | 7 | |
Display value | digit height 4 mm | |
Electrical specifications | ||
Operating voltage | 24 V DC | |
Power consumption | 0.3 W | |
Input | ||
Pulse length/pulse interval | 20 ms / 20 ms | |
Counting frequency | 25 Hz | |
Ambient conditions | ||
Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | flexible leads AWG 22 150 mm long | |
Mass | 18 g | |
Dimensions | 32 mm x 15 mm x 36 mm | |
Mounting | Locating springs | |
Life span | > 50 x 106 pulses |
Functional safety related parameters | ||
---|---|---|
MTTFd | 9300 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | digital display | |
Number of digits | 7 | |
Display value | digit height 4 mm | |
Electrical specifications | ||
Operating voltage | 230 V AC | |
Power consumption | 0.9 VA | |
Input | ||
Pulse length/pulse interval | 50 ms / 50 ms | |
Counting frequency | 10 Hz | |
Ambient conditions | ||
Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | flexible leads AWG 22 150 mm long | |
Mass | 18 g | |
Dimensions | 32 mm x 15 mm x 36 mm | |
Mounting | Locating springs | |
Life span | > 50 x 106 pulses |
General specifications | ||
---|---|---|
Pre-selection | single | |
Data storage | 106 storage cycles or 10 years, EEPROM | |
Programming | keypad-driven menu | |
Functional safety related parameters | ||
MTTFd | 330 a | |
Mission Time (TM) | 10 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Type | 7-segment LED display, red | |
Number of digits | 6 | |
Display value | digit height 14 mm | |
Pre-selection | active at counter value &le 0 | |
Key interlock | - | |
Display interval | -199999 ... 999999 with suppression of leading zeros | |
Decimal point | 0 to max 3 fractional digits | |
Scale factor | 0.0001 ... 99.9999 | |
Reset | manually or external | |
Electrical specifications | ||
Operating voltage | 90 ... 260 V AC | |
Power consumption | max. 6 VA | |
Input | ||
Counting frequency | 30 Hz / 20 kHz (max. 11 kHz when counting with phase discriminator) | |
Minimum pulse duration | 5 ms for reset input | |
Impedance | 10 kOhm | |
Voltage | low: 0 ... 4 V DC high: 12 ... 30 V DC | |
Counting method | adding or subtracting | |
Output | ||
Sensor supply | 24 V DC ± 15 % / 100 mA | |
Response time | 6 ms | |
Optocoupler | NPN, open collector and open emitter 30 V / 15 mA | |
Ambient conditions | ||
Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Relative humidity | &le 80 % (noncondensing) | |
Mechanical specifications | ||
Connection | 2-pin and 7-pin plug-in connection terminals, core cross-section &le 1.5 mm2 | |
Mass | approx. 150 g | |
Dimensions | 96 mm x 48 mm x 90 mm | |
Mounting | latch fastener (dimension 48 mm x 100 mm) |
General specifications | ||
---|---|---|
Data storage | 10 years, EEPROM | |
Programming | keypad-driven menu | |
Indicators/operating means | ||
Type | 7-segment LED display, red | |
Number of digits | 6 | |
Display value | digit height 15 mm | |
Display interval | -99999 ... 999999 | |
Decimal point | freely adjustable | |
Scale factor | 0.0001 ... 9.9999 | |
Reset | manually/external/automatically | |
Electrical specifications | ||
Operating voltage | 115 ... 230 V AC 16 ... 35 V DC | |
Power consumption | 7.5 VA | |
Input | ||
Counting frequency | 25 kHz (Timer function 1 kHz) | |
Impedance | 4.7 kOhm (positive logic) | |
Voltage | low: 0 ... 3.5 V DC high: 9 ... 35 V DC | |
Output | ||
Analog voltage output | -10/0 ... 10 DC | |
Analog current output | 0/4 ... 20 mA | |
Linearity | <0.1 % | |
Sensor supply | 24 V DC, 150 mA | |
Ambient conditions | ||
Ambient temperature | 0 ... 45 °C (32 ... 113 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Relative humidity | 45 ... 90 % (noncondensing) | |
Mechanical specifications | ||
Connection | screw terminals, removable max. core cross-section 0.34 ... 1.5 mm2 (AC max. 2.5 mm2) | |
Mass | approx. 450 g | |
Dimensions | 96 x 48 x 140 mm |
Описание оборудования | ||
---|---|---|
LCD operating hours counter with 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
LCD display with 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
Rotation Speed Monitor |
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 1.1 W | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
NAMUR sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 60947-5-6 (NAMUR) | |
Sensor supply | 8 V | |
Open-circuit | < 0.1 mA | |
Switching point | 1.2 ... 2.1 mA | |
Short-circuit | > 6 mA | |
Input impedance | 1 k&Omega | |
Mechanical contact | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Sensor supply | 15 V | |
External supply | &le 32 V | |
Switching point | 8 ... 10 V / 1.2 ... 2.1 mA | |
Frequency | 0 ... 50 Hz , debounce filter | |
Input impedance | 4 k&Omega | |
SN sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Sensor supply | 8 V | |
Open-circuit | < 0.1 mA | |
Switching point | 1.2 ... 2.1 mA | |
Short-circuit | > 6 mA | |
Input impedance | 1 k&Omega | |
2-wire DC sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 2 ... 5 mA | |
Input impedance | 1 k&Omega | |
S0 sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 62053-31 , Type B | |
Sensor supply | 15 V | |
Switching point | 0.15 ... 2 mA | |
Input impedance | 4 k&Omega | |
NPN sensor | ||
Type | 3-wire | |
Connection | terminals 5+, 6, 7- | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 3 ... 5 V | |
Input impedance | 4 k&Omega | |
PNP sensor | ||
Type | 3-wire | |
Connection | terminals 5+, 6, 7- | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 8 ... 10 V | |
Input impedance | 4 k&Omega | |
AC/DC voltage source | ||
Connection | terminals 6, 7- | |
Signal | max. ± 30 V | |
Switching point | 150 ... 400 mV | |
Input impedance | 4 k&Omega | |
Function input | ||
Connection | terminal 8 | |
Open loop voltage | 7.5 V | |
Input impedance | approx. 50 k&Omega | |
Function 1 | activation start-up override | |
Switching point | < 3 V , edge triggered | |
Adjustment range | 1 ... 6500 s | |
Function 2 | reset restart inhibit | |
Switching point | > 12 V , edge triggered | |
Output | ||
Connection side | control side | |
Connection | terminals 3, 4: | |
Output | signal, relay | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 30 V DC/2 A resistive load | |
Minimum switch current | 2 mA / 24 V DC | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Mechanical life | 107 switching cycles | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of the measurement value | |
Measuring time | &le 100 ms | |
Influence of ambient temperature | < 100 ppm/K of the measured value | |
Frequency range | 0.01 ... 50000 Hz | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches via software | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 60 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF adapter with USB interface S-ADP-USB Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP splitter VAZ-CHAIN-BU/BN70MM/1,0-25 |
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | terminals 14+, 15- | |
Rated voltage | 20 ... 30 V DC | |
Power consumption | max. 1.5 W | |
Input | ||
Connection side | field side | |
Connection | Input I: terminals 1+, 2+, 3- Input II: terminals 4+, 5+, 6- | |
Rated values | acc. to EN 60947-5-6 (NAMUR) | |
Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA | |
Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA | |
Line fault detection | not available | |
Control input | sensor power supply approx. 8.2 V, impedance 1.2 k&Omega | |
Pulse duration | > 200 µs for standstill monitoring, > 250 µs for rotation direction detecion | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 7, 8, 9 output II: terminals 10, 11, 12 | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
Minimum switch current | 2 mA / 24 V DC | |
Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
Mechanical life | 107 switching cycles | |
Trip value | for standstill monitoring: 0.1 Hz 0.5 Hz 2 Hz 10 Hz adjustable via DIP switch (S1 and S2) | |
Transfer characteristics | ||
Accuracy | 5 % (S3 = I), 30 % (S3 = II) | |
Start-up override | 5 seconds or 20 seconds, programmable | |
Frequency range | &le 2 kHz | |
Rotation direction detection | 90° phase difference between pulse input signal 1 and 2, overlapping &ge 125 µs | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 150 g | |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Описание оборудования | ||
---|---|---|
Temperature control unit with LED display and 90 ... 260 VAC supply voltage |
Описание оборудования | ||
---|---|---|
Temperature control unit with LED display and 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 1 relay output and 230 VAC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 1 relay output and 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
Pulse/batch controller |
Описание оборудования | ||
---|---|---|
LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 2 relay outputs and 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 2 optocoupler outputs and 90 ... 260 VAC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 2 optocoupler outputs and 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 6 optocoupler outputs and 90 ... 260 VAC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 6 optocoupler outputs and 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 2 relay outputs and 90 ... 260 VAC supply voltage |
Описание оборудования | ||
---|---|---|
LCD batch controller with 2 relay outputs and 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
LED display with 24 VDC supply voltage |
Описание оборудования | ||
---|---|---|
Counter  |
Товаров: 0
На сумму: 0