Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Описание оборудования | ||
---|---|---|
Adapter with USB Interface |
Описание оборудования | ||
---|---|---|
Cover for 35 mm DIN mounting rail, length: 250 mm |
Описание оборудования | ||
---|---|---|
25-point wiring link for control cabinet modules with screw terminals |
Описание оборудования | ||
---|---|---|
End Cap for Power Bus |
Описание оборудования | ||
---|---|---|
Power bus for 35 mm DIN mounting rail, height: 15 mm, length: 250 mm |
Описание оборудования | ||
---|---|---|
Power bus for 35 mm DIN mounting rail, height: 15 mm, length: 500 mm |
Описание оборудования | ||
---|---|---|
Power bus for 35 mm DIN mounting rail, height: 7.5 mm, length: 250 mm |
Описание оборудования | ||
---|---|---|
Power bus for 35 mm DIN mounting rail, height: 7.5 mm, length: 500 mm |
Описание оборудования | ||
---|---|---|
Power feed module, screw terminals |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 0.7 W | |
Input | ||
Connection side | field side | |
Transmission range | linearity range: -1 ... 110 % | |
Input I | ||
Input signal | 0/4 ... 20 mA , max. 50 mA | |
Input resistance | &le 25 &Omega | |
Input II | ||
Input signal | 0/2 ... 10 V , max. 30 V | |
Input resistance | > 100 k&Omega | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 10 Hz , 0 ... 100 Hz , 0 ... 5 kHz | |
Settling time | 70 ms , 7 ms , 150 µs | |
Indicators/settings | ||
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 0.8 W | |
Input | ||
Connection side | field side | |
Transmission range | linearity range: unipolar -1 ... 110 % bipolar -110 ... 110 % | |
Input I | ||
Input signal | 0/4 ... 20 mA , 0/2 ... 10 mA , ± 10 mA, ± 20 mA , max. 50 mA | |
Input resistance | &le 25 &Omega | |
Input II | ||
Input signal | 0/1 ... 5 V , 0/2 ... 10 V , ± 5 V , ± 10 V , max. 30 V | |
Input resistance | > 1 M&Omega | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz , 0 ... 8 kHz | |
Settling time | 7 ms , 100 µs | |
Indicators/settings | ||
Control elements | DIP-switch potentiometer | |
Configuration | via DIP switches via potentiometer | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.8 W | |
Power consumption | 1.4 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6- | |
Input signal | 0/4 ... 20 mA | |
Open circuit voltage/short-circuit current | &le 22 V / 35 mA | |
Input resistance | &le 25 &Omega | |
Transmission range | linearity range: -1 ... 110 % | |
Available voltage | 16 V at 20 mA | |
Output | ||
Connection side | control side | |
Ripple | &le 10 mV eff | |
Output I | ||
Connection | terminals 3-, 4+ | |
Output signal | 0/1 ... 5 V, 0/2 ... 10 V , load &ge 5 k&Omega 0/4 ... 20 mA , load &le 300 &Omega | |
Output II | ||
Connection | terminals 7+, 8- | |
Output signal | 0/1 ... 5 V, 0/2 ... 10 V , load &ge 5 k&Omega 0/4 ... 20 mA , load &le 300 &Omega | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz | |
Rise time/fall time | &le 3.5 ms | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 0.8 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6- | |
Input signal | ±60 mV, ±100 mV, ±150 mV, ±250 mV, ±300 mV, ±500 mV | |
Input resistance | &ge 100 k&Omega | |
Transmission range | linearity range: unipolar -1 ... 110 % bipolar -110 ... 110 % | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz , 0 ... 8 kHz | |
Settling time | 7 ms , 150 µs | |
Indicators/settings | ||
Control elements | DIP-switch potentiometer | |
Configuration | via DIP switches via potentiometer | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Rated voltage | 2.2 ... 30 V DC , loop powered | |
Power dissipation | 0.05 W | |
Power consumption | 0.3 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6- | |
Input signal | 0/4 ... 20 mA , max. 50 mA | |
Voltage drop | &le 2.3 V | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz | |
Rise time/fall time | &le 3.5 ms | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Rated voltage | 2.2 ... 30 V DC , loop powered | |
Power dissipation | 0.1 W | |
Power consumption | 0.6 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6- 7+, 8- | |
Input signal | 0/4 ... 20 mA , max. 50 mA | |
Voltage drop | &le 2.3 V | |
Output | ||
Connection side | control side | |
Connection | terminals 1-, 2+ 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz | |
Rise time/fall time | &le 3.5 ms | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc |
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 1.1 W | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
NAMUR sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 60947-5-6 (NAMUR) | |
Sensor supply | 8 V | |
Open-circuit | < 0.1 mA | |
Switching point | 1.2 ... 2.1 mA | |
Short-circuit | > 6 mA | |
Input impedance | 1 k&Omega | |
Mechanical contact | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Sensor supply | 15 V | |
External supply | &le 32 V | |
Switching point | 8 ... 10 V / 1.2 ... 2.1 mA | |
Frequency | 0 ... 50 Hz , debounce filter | |
Input impedance | 4 k&Omega | |
SN sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Sensor supply | 8 V | |
Open-circuit | < 0.1 mA | |
Switching point | 1.2 ... 2.1 mA | |
Short-circuit | > 6 mA | |
Input impedance | 1 k&Omega | |
2-wire DC sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 2 ... 5 mA | |
Input impedance | 1 k&Omega | |
S0 sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 62053-31 , Type B | |
Sensor supply | 15 V | |
Switching point | 0.15 ... 2 mA | |
Input impedance | 4 k&Omega | |
NPN sensor | ||
Type | 3-wire | |
Connection | terminals 5+, 6, 7- | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 3 ... 5 V | |
Input impedance | 4 k&Omega | |
PNP sensor | ||
Type | 3-wire | |
Connection | terminals 5+, 6, 7- | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 8 ... 10 V | |
Input impedance | 4 k&Omega | |
AC/DC voltage source | ||
Connection | terminals 6, 7- | |
Signal | max. ± 30 V | |
Switching point | 150 ... 400 mV | |
Input impedance | 4 k&Omega | |
Function input | ||
Connection | terminal 8 | |
Open loop voltage | 7.5 V | |
Input impedance | approx. 50 k&Omega | |
Function 1 | activation start-up override | |
Switching point | < 3 V , edge triggered | |
Adjustment range | 1 ... 6500 s | |
Function 2 | reset restart inhibit | |
Switching point | > 12 V , edge triggered | |
Output | ||
Connection side | control side | |
Connection | terminals 3, 4: | |
Output | signal, relay | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 30 V DC/2 A resistive load | |
Minimum switch current | 2 mA / 24 V DC | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Mechanical life | 107 switching cycles | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of the measurement value | |
Measuring time | &le 100 ms | |
Influence of ambient temperature | < 100 ppm/K of the measured value | |
Frequency range | 0.01 ... 50000 Hz | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches via software | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 60 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF adapter with USB interface S-ADP-USB Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP splitter VAZ-CHAIN-BU/BN70MM/1,0-25 |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.9 W | |
Power consumption | 1.3 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6, 7- | |
Input signal | 0/4 ... 20 mA | |
Open circuit voltage/short-circuit current | &le 22 V / 30 mA | |
Input resistance | max. 50 &Omega | |
Transmission range | linearity range: -1 ... 110 % | |
Available voltage | 16 V at 20 mA | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Rise time/fall time | &le 3.5 ms | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 1.1 W | |
Input | ||
Connection side | field side | |
NAMUR sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 60947-5-6 (NAMUR) | |
Sensor supply | 8 V | |
Open-circuit | < 0.1 mA | |
Switching point | 1.2 ... 2.1 mA | |
Short-circuit | > 6 mA | |
Input impedance | 1 k&Omega | |
Mechanical contact | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Sensor supply | 15 V | |
External supply | &le 32 V | |
Switching point | 8 ... 10 V / 1.2 ... 2.1 mA | |
Input impedance | 4 k&Omega | |
SN sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Sensor supply | 8 V | |
Open-circuit | < 0.1 mA | |
Switching point | 1.2 ... 2.1 mA | |
Short-circuit | > 6 mA | |
Input impedance | 1 k&Omega | |
2-wire DC sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 2 ... 5 mA | |
Input impedance | 1 k&Omega | |
S0 sensor | ||
Type | 2-wire | |
Connection | terminals 5+, 6 | |
Signal | acc. to EN 62053-31 , Type B | |
Sensor supply | 15 V | |
Switching point | 0.15 ... 2 mA | |
Input impedance | 4 k&Omega | |
NPN sensor | ||
Type | 3-wire | |
Connection | terminals 5+, 6, 7- | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 3 ... 5 V | |
Input impedance | 4 k&Omega | |
PNP sensor | ||
Type | 3-wire | |
Connection | terminals 5+, 6, 7- | |
Signal | acc. to EN 60947-5-2 | |
Sensor supply | 16 V / 25 mA , short-circuit protected | |
External supply | &le 32 V | |
Switching point | 8 ... 10 V | |
Input impedance | 4 k&Omega | |
AC/DC voltage source | ||
Connection | terminals 7, 8 | |
Signal | 24 V AC/DC | |
Switching point | 10 ... 15 V | |
Input impedance | > 680 k&Omega | |
AC/DC voltage source | ||
Connection | terminals 7, 8 | |
Signal | 115 V AC/DC | |
Switching point | 40 ... 60 V | |
Input impedance | > 680 k&Omega | |
AC/DC voltage source | ||
Connection | terminals 7, 8 | |
Signal | 230 V AC/DC | |
Switching point | 80 ... 115 V | |
Input impedance | > 680 k&Omega | |
Output | ||
Connection side | control side | |
Connection | terminals 3, 4: | |
Output | signal, relay | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/2 A/cos &phi > 0.7 30 V DC/2 A resistive load | |
Minimum switch current | 2 mA / 24 V DC | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Mechanical life | 107 switching cycles | |
Transfer characteristics | ||
Switching frequency | &le 10 Hz | |
Indicators/settings | ||
Control elements | DIP-switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 60 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.7 W | |
Power consumption | 0.8 W | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 5, 6, 7, 8 | |
PTC | type KT, KTY, ST | |
Measuring current | approx. 200 µA | |
Types of measuring | 2-, 3-, 4-wire connection | |
Lead resistance | &le 100 &Omega per line | |
Measurement loop monitoring | sensor breakage, lead breakage, short circuit | |
RTD | type Pt100, Pt200, Pt500, Pt1000 (EN 60751: 1995) type Ni100, Ni200, Ni500, Ni1000 (DIN 43760) | |
Measuring current | approx. 200 µA | |
Types of measuring | 2-, 3-, 4-wire connection | |
Lead resistance | max. 100 &Omega per line | |
Measurement loop monitoring | sensor breakage, lead breakage, short circuit | |
Thermocouples | type B, E, J, K, N, S, T (IEC 584-1:1995) type L, U (DIN 43710:1985) type C, D (ASTM E988) | |
Cold junction compensation | external (Pt100) and internal , manually | |
Lead resistance | max. 10 k&Omega | |
Measurement loop monitoring | sensor breakage, lead breakage | |
Resistor | ||
Measurement range | 0 ... 5 k&Omega | |
Potentiometer | 0.2 ... 50 k&Omega | |
Types of measuring | 3-wire connection | |
Voltage | -100 ... 100 mV -1000 ... 1000 mV | |
Input resistance | &ge 1 M&Omega | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Fault signal | downscale or upscale | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Measuring time | &le 300 ms | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Indicators/settings | ||
Control elements | DIP-switch keys | |
Configuration | via DIP switches via keys via software | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF adapter with USB interface S-ADP-USB Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.9 W | |
Power consumption | 1.3 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6, 7- | |
Input signal | 0/4 ... 20 mA | |
Open circuit voltage/short-circuit current | &le 22 V / 30 mA | |
Input resistance | 25 &Omega | |
Transmission range | linearity range: -1 ... 110 % | |
Available voltage | 16 V at 20 mA | |
Output | ||
Connection side | control side | |
Connection | terminals 3-, 4+ | |
Ripple | &le 10 mV eff | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz | |
Rise time/fall time | &le 3.5 ms | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.8 W | |
Power consumption | 1.4 W | |
Input | ||
Connection side | field side | |
Connection | terminals 5+, 6- | |
Input signal | 0/4 ... 20 mA | |
Open circuit voltage/short-circuit current | &le 22 V / 35 mA | |
Input resistance | &le 25 &Omega | |
Transmission range | linearity range: -1 ... 110 % | |
Available voltage | 16 V at 20 mA | |
Output | ||
Connection side | control side | |
Ripple | &le 10 mV eff | |
Output I | ||
Connection | terminals 3-, 4+ | |
Output signal | 0/4 ... 20 mA, load &le 300 &Omega | |
Output II | ||
Connection | terminals 7+, 8- | |
Output signal | 0/4 ... 20 mA, load &le 300 &Omega | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Frequency range | 0 ... 100 Hz | |
Rise time/fall time | &le 3.5 ms | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 16 ATEX 1750X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
International approvals | ||
UL approval | E106378 | |
IECEx approval | IECEx UL 16.0116X | |
Approved for | Ex nA IIC T4 Gc | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Bus or terminals 1-, 2+ | |
Rated voltage | 16.8 ... 31.2 V DC | |
Power dissipation | 0.6 W | |
Power consumption | 0.8 W | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Transmission range | linearity range: unipolar -1 ... 110 % bipolar -110 ... 110 % | |
Input I | ||
Input signal | 0/4 ... 20 mA , 0/2 ... 10 mA , ± 10 mA, ± 20 mA , max. 50 mA | |
Input resistance | &le 25 &Omega | |
Input II | ||
Input signal | 0/1 ... 5 V , 0/2 ... 10 V , ± 5 V , ± 10 V , max. 30 V | |
Input resistance | > 1 M&Omega | |
Input III | ||
Connection | terminals 5+, 6- | |
Input signal | 0/4 ... 20 mA | |
Available voltage | 16 V at 20 mA | |
Open circuit voltage/short-circuit current | &le 22 V / 30 mA | |
Input IV | ||
Connection | terminals 5, 7 | |
Input type | reset restart inhibit | |
Output | ||
Connection side | control side | |
Connection | terminals 3, 4: | |
Output | signal, relay | |
Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/2 A/cos &phi > 0.7 30 V DC/2 A resistive load | |
Minimum switch current | 2 mA / 24 V DC | |
Energized/De-energized delay | &le 20 ms / &le 20 ms | |
Mechanical life | 107 switching cycles | |
Collective error message | Power Bus | |
Transfer characteristics | ||
Accuracy | max. 0.1 % of full-scale value | |
Influence of ambient temperature | < 100 ppm/K of full-scale value | |
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch keys | |
Configuration | via DIP switches via keys via software | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
Mass | approx. 70 g | |
Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Accessories | ||
Optional accessories | power feed module S1SD-2PF Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP |
Товаров: 0