| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.62 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.35 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Constant magnetic field | 100 mT | |
| Alternating magnetic field | 100 mT | |
| Operating voltage indicator | LED green | |
| Switching state indicator | Switching state "closed" = LED red (S2) switching state "open" = LED yellow (S1)  | |
| Functional safety related parameters | ||
| MTTFd | 1402 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Flexible lead, housing-sensor | 100 mm , PUR (halogen-free) | |
| Housing material | Amplifier: PA66 Badamid,  Oscillators: PBT  | |
| Degree of protection | IP65 | |
| Описание оборудования | ||
|---|---|---|
| Satellite unit | ||
| Описание оборудования | ||
|---|---|---|
| Satellite unit | ||
| Описание оборудования | ||
|---|---|---|
| Satellite unit | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.4 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 10 mA | |
| Operating voltage indicator | 1 green LED green for each sensor | |
| Switching state indicator | 1 yellow LED for each sensor | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin , | |
| Housing material | PA 6 Metal fixing block for M6-screw  | |
| Degree of protection | IP65 | |
| Note | El. Data for each sensor Available accessory: Clear view cover SH-F1C  | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.4 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 500 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| No-load supply current | &le 10 mA | |
| Operating voltage indicator | 1 green LED green for each sensor | |
| Switching state indicator | 1 yellow LED for each sensor | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin , | |
| Degree of protection | IP65 | |
| Note | Available accessories: clear cover SH-FX | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2)  30 mm x 30 mm x 1 mm  | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.4 | |
| Nominal ratings | ||
| Installation conditions | ||
| B | 25 mm | |
| C | 16 mm | |
| F | 37 mm | |
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 300 Hz | |
| Hysteresis | 0.05 ... 2.2 mm | |
| Reverse polarity protection | yes | |
| Short-circuit protection | yes | |
| Overload resistance | yes | |
| Wire breakage protection | yes | |
| Inductive overvoltage protection | yes | |
| Surge suppression | yes | |
| Ripple | 10 % | |
| Voltage drop | &le 2.5 V | |
| Repeat accuracy | 0.3 mm | |
| Operating current | 0 ... 200 mA up to 85 °C, above this temperature max 150 mA | |
| Off-state current | &le 0.01 mA | |
| No-load supply current | &le 7 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Mass | 80 g | |
| General information | ||
| Note | The sensor can be operated at ambient temperatures of up to 120 °C for short periods (<30 minutes). In such cases, the output load capacity drops to 100 mA. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm typ. 10 mm | |
| Reduction factor rAl | 0.22 | |
| Reduction factor rCu | 0.19 | |
| Reduction factor r304 | 0.66 | |
| Reduction factor rBrass | 0.33 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 60 V | |
| Switching frequency | 0 ... 800 Hz | |
| Hysteresis | 1 ... 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.8 V | |
| Voltage drop at IL | ||
| Voltage drop IL = 10 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V | |
| Voltage drop IL = 20 mA, switching element on | 0.9 ... 2.4 V typ. 1.7 V | |
| Voltage drop IL = 50 mA, switching element on | 0.9 ... 2.5 V typ. 1.7 V | |
| Voltage drop IL = 100 mA, switching element on | 1 ... 2.6 V typ. 1.8 V | |
| Voltage drop IL = 200 mA, switching element on | 1.2 ... 2.8 V typ. 2 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.01 mA | |
| No-load supply current | &le 9 mA | |
| Switching state indicator | - | |
| Standard conformity | ||
| Standards | IEC / EN 60947-5-2:2004 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Mechanical specifications | ||
| Core cross-section | 0.75 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP68 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 2 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 1.62 mm | |
| Actual operating distance | 1.8 ... 2.2 mm typ. | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 1 ... 10 typ. 3 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Voltage drop at IL | ||
| Voltage drop IL = 100 mA, switching element on | 1.2 ... 2.5 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Standard conformity | ||
| Standards | IEC / EN 60947-5-2:2004 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush | |
| Assured operating distance | 0 ... 2.4 mm | |
| Actual operating distance | 2.7 ... 3.3 mm typ. | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Hysteresis | typ. 0.2 % | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Limit data | ||
| Tightening torque, fastening screws | 0.4 Nm | |
| Standard conformity | ||
| Standards | EN 50044 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Installation | ||
| Output polarity | DC | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm | |
| Material | 1.4401 | |
| Passage speed | &le 10 m/s | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Output voltage | ||
| Traverse A | 1 V | |
| Traverse B | UB - 3 V | |
| Power ON | 1 V | |
| Voltage drop | &le 1.5 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 10 mA | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Cable diameter | 3 mm | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cylinder | 9S20K | |
| Diameter | 2.5 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 2.5 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 18 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 2.5 mm | |
| Length | 3 mm | |
| Measuring cone | ||
| Material | 9S20K | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 2144 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 2.5 mm | |
| Length | 3 mm | |
| Measuring cone | ||
| Material | 9S20K | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 1/8" (3.175mm) | |
| Measuring cone | Carboloy | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Traverse A | 1 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Functional safety related parameters | ||
| MTTFd | 2140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10  | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 20 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10  | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Installation | non-flush | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 1/8" (3.175mm) | |
| Measuring cone | Carboloy/high grade steel | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cylinder | 9S20K | |
| Diameter | 3 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 5990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 5990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 5990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 18 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cylinder | Fe-metal | |
| Diameter | 3 mm | |
| Length | 4 mm | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 2240 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cylinder | ||
| Diameter | 1/4" (6.250mm) | |
| Measuring cone | Carboloy | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Traverse A | 1 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Functional safety related parameters | ||
| MTTFd | 2240 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10  | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 20 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10  | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m  Crimp terminal sockets 60888-3, AMP  | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cylinder | ||
| Diameter | 1/4" (6.250mm) | |
| Measuring cone | Carboloy | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Traverse A | 1 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Functional safety related parameters | ||
| MTTFd | 2240 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000  IEC 60947-5-6:1999  | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP/NPN | |
| Installation | non-flush | |
| Output polarity | DC | |
| Measuring cylinder | ||
| Diameter | 15 mm | |
| Length | 15 mm | |
| Ring diameter | 102 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 20 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | no | |
| Voltage drop | < 1 V | |
| Operating current | 12 mA | |
| Off-state current | 2 µA | |
| Switching state indicator | LED, red | |
| Indicators/operating means | ||
| Potentiometer | sensitivity adjustment , 15 turns | |
| Output | ||
| Load current | 100 mA ( NPN )  50 mA ( PNP )  | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin micro connector ( M12 x 1 ) | |
| Housing material | ABS | |
| Degree of protection | IP65 | |