Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Описание оборудования | ||
|---|---|---|
| Switch Amplifier | ||
| Описание оборудования | ||
|---|---|---|
| 48 V AC ... 253 V AC/20 V DC ... 90 V DC | ||
| Описание оборудования | ||
|---|---|---|
| 48 V AC ... 253 V AC/20 V DC ... 90 V DC | ||
| Описание оборудования | ||
|---|---|---|
| Frequency voltage current converter 40 kHz version | ||
| Описание оборудования | ||
|---|---|---|
| Frequency voltage current converter 40 kHz version | ||
| Описание оборудования | ||
|---|---|---|
| Sensor output interface terminal | ||
| Описание оборудования | ||
|---|---|---|
| Sensor output interface terminal with lead breakage monitoring | ||
| Описание оборудования | ||
|---|---|---|
| Sensor output interface terminal | ||
| Описание оборудования | ||
|---|---|---|
| Sensor output interface terminal with lead breakage monitoring | ||
| Описание оборудования | ||
|---|---|---|
| Sensor output interface terminals with relay output | ||
| Описание оборудования | ||
|---|---|---|
| Signal converter SSI/RS 232/Parallel | ||
| Описание оборудования | ||
|---|---|---|
| Signal converter SSI/Analog | ||
| Описание оборудования | ||
|---|---|---|
| Batch controller | ||
| Описание оборудования | ||
|---|---|---|
| Batch controller | ||
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 2400 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | digital display | |
| Number of digits | 5 | |
| Display value | digit height 4 mm | |
| Reset | manually | |
| Electrical specifications | ||
| Operating voltage | 24 V DC | |
| Power consumption | 0.6 W | |
| Input | ||
| Pulse length/pulse interval | 50 ms / 50 ms | |
| Counting frequency | 10 Hz | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
| Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | flexible leads AWG 22 150 mm long | |
| Mass | 62 g | |
| Dimensions | 48 mm x 24 mm x 59 mm | |
| Mounting | latch fastener | |
| Life span | > 50 x 106 pulses | |
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 2400 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | digital display | |
| Number of digits | 5 | |
| Display value | digit height 4 mm | |
| Reset | manually | |
| Electrical specifications | ||
| Operating voltage | 230 V AC | |
| Power consumption | 1.3 VA | |
| Input | ||
| Pulse length/pulse interval | 50 ms / 50 ms | |
| Counting frequency | 10 Hz | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
| Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | flexible leads AWG 22 150 mm long | |
| Mass | 48 g | |
| Dimensions | 48 mm x 24 mm x 59 mm | |
| Mounting | latch fastener | |
| Life span | > 50 x 106 pulses | |
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 4600 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | digital display | |
| Number of digits | 7 | |
| Display value | digit height 4 mm | |
| Electrical specifications | ||
| Operating voltage | 24 V DC | |
| Power consumption | 0.6 W | |
| Input | ||
| Pulse length/pulse interval | 50 ms / 50 ms | |
| Counting frequency | 10 Hz | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
| Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | flexible leads AWG 22 150 mm long | |
| Mass | 60 g | |
| Dimensions | 48 mm x 24 mm x 54 mm | |
| Mounting | latch fastener | |
| Life span | > 50 x 106 pulses | |
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 4600 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | digital display | |
| Number of digits | 7 | |
| Display value | digit height 4 mm | |
| Electrical specifications | ||
| Operating voltage | 230 V AC | |
| Power consumption | 1.3 VA | |
| Input | ||
| Pulse length/pulse interval | 50 ms / 50 ms | |
| Counting frequency | 10 Hz | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
| Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | flexible leads AWG 22 150 mm long | |
| Mass | 50 g | |
| Dimensions | 48 mm x 24 mm x 54 mm | |
| Mounting | latch fastener | |
| Life span | > 50 x 106 pulses | |
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 9300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | digital display | |
| Number of digits | 7 | |
| Display value | digit height 4 mm | |
| Electrical specifications | ||
| Operating voltage | 24 V DC | |
| Power consumption | 0.3 W | |
| Input | ||
| Pulse length/pulse interval | 20 ms / 20 ms | |
| Counting frequency | 25 Hz | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
| Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | flexible leads AWG 22 150 mm long | |
| Mass | 18 g | |
| Dimensions | 32 mm x 15 mm x 36 mm | |
| Mounting | Locating springs | |
| Life span | > 50 x 106 pulses | |
| Functional safety related parameters | ||
|---|---|---|
| MTTFd | 9300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | digital display | |
| Number of digits | 7 | |
| Display value | digit height 4 mm | |
| Electrical specifications | ||
| Operating voltage | 230 V AC | |
| Power consumption | 0.9 VA | |
| Input | ||
| Pulse length/pulse interval | 50 ms / 50 ms | |
| Counting frequency | 10 Hz | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
| Storage temperature | -40 ... 90 °C (-40 ... 194 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | flexible leads AWG 22 150 mm long | |
| Mass | 18 g | |
| Dimensions | 32 mm x 15 mm x 36 mm | |
| Mounting | Locating springs | |
| Life span | > 50 x 106 pulses | |
| General specifications | ||
|---|---|---|
| Pre-selection | single | |
| Data storage | 106 storage cycles or 10 years, EEPROM | |
| Programming | keypad-driven menu | |
| Functional safety related parameters | ||
| MTTFd | 330 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Type | 7-segment LED display, red | |
| Number of digits | 6 | |
| Display value | digit height 14 mm | |
| Pre-selection | active at counter value &le 0 | |
| Key interlock | - | |
| Display interval | -199999 ... 999999 with suppression of leading zeros | |
| Decimal point | 0 to max 3 fractional digits | |
| Scale factor | 0.0001 ... 99.9999 | |
| Reset | manually or external | |
| Electrical specifications | ||
| Operating voltage | 90 ... 260 V AC | |
| Power consumption | max. 6 VA | |
| Input | ||
| Counting frequency | 30 Hz / 20 kHz (max. 11 kHz when counting with phase discriminator) | |
| Minimum pulse duration | 5 ms for reset input | |
| Impedance | 10 kOhm | |
| Voltage | low: 0 ... 4 V DC high: 12 ... 30 V DC | |
| Counting method | adding or subtracting | |
| Output | ||
| Sensor supply | 24 V DC ± 15 % / 100 mA | |
| Response time | 6 ms | |
| Optocoupler | NPN, open collector and open emitter 30 V / 15 mA | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Relative humidity | &le 80 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | 2-pin and 7-pin plug-in connection terminals, core cross-section &le 1.5 mm2 | |
| Mass | approx. 150 g | |
| Dimensions | 96 mm x 48 mm x 90 mm | |
| Mounting | latch fastener (dimension 48 mm x 100 mm) | |
| General specifications | ||
|---|---|---|
| Data storage | 10 years, EEPROM | |
| Programming | keypad-driven menu | |
| Indicators/operating means | ||
| Type | 7-segment LED display, red | |
| Number of digits | 6 | |
| Display value | digit height 15 mm | |
| Display interval | -99999 ... 999999 | |
| Decimal point | freely adjustable | |
| Scale factor | 0.0001 ... 9.9999 | |
| Reset | manually/external/automatically | |
| Electrical specifications | ||
| Operating voltage | 115 ... 230 V AC 16 ... 35 V DC | |
| Power consumption | 7.5 VA | |
| Input | ||
| Counting frequency | 25 kHz (Timer function 1 kHz) | |
| Impedance | 4.7 kOhm (positive logic) | |
| Voltage | low: 0 ... 3.5 V DC high: 9 ... 35 V DC | |
| Output | ||
| Analog voltage output | -10/0 ... 10 DC | |
| Analog current output | 0/4 ... 20 mA | |
| Linearity | <0.1 % | |
| Sensor supply | 24 V DC, 150 mA | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 45 °C (32 ... 113 °F) | |
| Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Relative humidity | 45 ... 90 % (noncondensing) | |
| Mechanical specifications | ||
| Connection | screw terminals, removable max. core cross-section 0.34 ... 1.5 mm2 (AC max. 2.5 mm2) | |
| Mass | approx. 450 g | |
| Dimensions | 96 x 48 x 140 mm | |
| Описание оборудования | ||
|---|---|---|
| LCD operating hours counter with 24 VDC supply voltage | ||
| Описание оборудования | ||
|---|---|---|
| LCD display with 24 VDC supply voltage | ||
| Описание оборудования | ||
|---|---|---|
| Rotation Speed Monitor | ||
| General specifications | ||
|---|---|---|
| Signal type | Digital Input | |
| Supply | ||
| Connection | Power Bus or terminals 1-, 2+ | |
| Rated voltage | 16.8 ... 31.2 V DC | |
| Power dissipation | 0.6 W | |
| Power consumption | 1.1 W | |
| Interface | ||
| Programming interface | programming socket | |
| Input | ||
| Connection side | field side | |
| NAMUR sensor | ||
| Type | 2-wire | |
| Connection | terminals 5+, 6 | |
| Signal | acc. to EN 60947-5-6 (NAMUR) | |
| Sensor supply | 8 V | |
| Open-circuit | < 0.1 mA | |
| Switching point | 1.2 ... 2.1 mA | |
| Short-circuit | > 6 mA | |
| Input impedance | 1 k&Omega | |
| Mechanical contact | ||
| Type | 2-wire | |
| Connection | terminals 5+, 6 | |
| Sensor supply | 15 V | |
| External supply | &le 32 V | |
| Switching point | 8 ... 10 V / 1.2 ... 2.1 mA | |
| Frequency | 0 ... 50 Hz , debounce filter | |
| Input impedance | 4 k&Omega | |
| SN sensor | ||
| Type | 2-wire | |
| Connection | terminals 5+, 6 | |
| Sensor supply | 8 V | |
| Open-circuit | < 0.1 mA | |
| Switching point | 1.2 ... 2.1 mA | |
| Short-circuit | > 6 mA | |
| Input impedance | 1 k&Omega | |
| 2-wire DC sensor | ||
| Type | 2-wire | |
| Connection | terminals 5+, 6 | |
| Signal | acc. to EN 60947-5-2 | |
| Sensor supply | 16 V / 25 mA , short-circuit protected | |
| External supply | &le 32 V | |
| Switching point | 2 ... 5 mA | |
| Input impedance | 1 k&Omega | |
| S0 sensor | ||
| Type | 2-wire | |
| Connection | terminals 5+, 6 | |
| Signal | acc. to EN 62053-31 , Type B | |
| Sensor supply | 15 V | |
| Switching point | 0.15 ... 2 mA | |
| Input impedance | 4 k&Omega | |
| NPN sensor | ||
| Type | 3-wire | |
| Connection | terminals 5+, 6, 7- | |
| Signal | acc. to EN 60947-5-2 | |
| Sensor supply | 16 V / 25 mA , short-circuit protected | |
| External supply | &le 32 V | |
| Switching point | 3 ... 5 V | |
| Input impedance | 4 k&Omega | |
| PNP sensor | ||
| Type | 3-wire | |
| Connection | terminals 5+, 6, 7- | |
| Signal | acc. to EN 60947-5-2 | |
| Sensor supply | 16 V / 25 mA , short-circuit protected | |
| External supply | &le 32 V | |
| Switching point | 8 ... 10 V | |
| Input impedance | 4 k&Omega | |
| AC/DC voltage source | ||
| Connection | terminals 6, 7- | |
| Signal | max. ± 30 V | |
| Switching point | 150 ... 400 mV | |
| Input impedance | 4 k&Omega | |
| Function input | ||
| Connection | terminal 8 | |
| Open loop voltage | 7.5 V | |
| Input impedance | approx. 50 k&Omega | |
| Function 1 | activation start-up override | |
| Switching point | < 3 V , edge triggered | |
| Adjustment range | 1 ... 6500 s | |
| Function 2 | reset restart inhibit | |
| Switching point | > 12 V , edge triggered | |
| Output | ||
| Connection side | control side | |
| Connection | terminals 3, 4: | |
| Output | signal, relay | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 30 V DC/2 A resistive load | |
| Minimum switch current | 2 mA / 24 V DC | |
| Energized/De-energized delay | &le 20 ms / &le 20 ms | |
| Mechanical life | 107 switching cycles | |
| Transfer characteristics | ||
| Accuracy | max. 0.1 % of the measurement value | |
| Measuring time | &le 100 ms | |
| Influence of ambient temperature | < 100 ppm/K of the measured value | |
| Frequency range | 0.01 ... 50000 Hz | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches via software | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Core cross-section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | |
| Mass | approx. 60 g | |
| Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Accessories | ||
| Optional accessories | power feed module S1SD-2PF adapter with USB interface S-ADP-USB Power Bus POWERBUS-SETL5.*** Power Bus POWERBUS-SETH5.*** cover for DIN mounting rail POWERBUS-COV.250 end cap POWERBUS-CAP splitter VAZ-CHAIN-BU/BN70MM/1,0-25 | |
| General specifications | ||
|---|---|---|
| Signal type | Digital Input | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Supply | ||
| Connection | terminals 14+, 15- | |
| Rated voltage | 20 ... 30 V DC | |
| Power consumption | max. 1.5 W | |
| Input | ||
| Connection side | field side | |
| Connection | Input I: terminals 1+, 2+, 3- Input II: terminals 4+, 5+, 6- | |
| Rated values | acc. to EN 60947-5-6 (NAMUR) | |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA | |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA | |
| Line fault detection | not available | |
| Control input | sensor power supply approx. 8.2 V, impedance 1.2 k&Omega | |
| Pulse duration | > 200 µs for standstill monitoring, > 250 µs for rotation direction detecion | |
| Output | ||
| Connection side | control side | |
| Connection | output I: terminals 7, 8, 9 output II: terminals 10, 11, 12 | |
| Contact loading | 253 V AC/2 A/cos &phi > 0.7 126.5 V AC/4 A/cos &phi > 0.7 40 V DC/2 A resistive load | |
| Minimum switch current | 2 mA / 24 V DC | |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
| Mechanical life | 107 switching cycles | |
| Trip value | for standstill monitoring: 0.1 Hz 0.5 Hz 2 Hz 10 Hz adjustable via DIP switch (S1 and S2) | |
| Transfer characteristics | ||
| Accuracy | 5 % (S3 = I), 30 % (S3 = II) | |
| Start-up override | 5 seconds or 20 seconds, programmable | |
| Frequency range | &le 2 kHz | |
| Rotation direction detection | 90° phase difference between pulse input signal 1 and 2, overlapping &ge 125 µs | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Low voltage | ||
| Directive 2014/35/EU | EN 61010-1:2010 | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| Mass | approx. 150 g | |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Описание оборудования | ||
|---|---|---|
| Temperature control unit with LED display and 90 ... 260 VAC supply voltage | ||
| Описание оборудования | ||
|---|---|---|
| Temperature control unit with LED display and 24 VDC supply voltage | ||
| Описание оборудования | ||
|---|---|---|
| LCD batch controller with 1 relay output and 230 VAC supply voltage | ||
Товаров: 0
На сумму: 0