General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Reed Contact | |
Rated operating distance | 61 mm | |
Installation | non-flush | |
Mechanical life | 1 x 107 switching cycles | |
Nominal ratings | ||
Operating voltage | 250 V DC, 1.0 A max, 15 W | |
Hysteresis | 15.2 mm | |
Release point | &le max. 76 mm | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 1.83 m | |
Core cross-section | 16 AWG | |
Housing material | aluminum | |
Sensing face | aluminum | |
Housing diameter | ||
Degree of protection | IP68 | |
Material | ||
Activation target | 21FR1-B |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Reed Contact | |
Rated operating distance | 19.8 mm | |
Installation | non-flush | |
Output polarity | AC/DC | |
Mechanical life | 3 x 107 operations | |
Nominal ratings | ||
Operating voltage | 100 V DC, 250 mA 115 V AC, 250 mA | |
Hysteresis | &ge2.54 mm | |
Contact resistance | 0.15 &Omega | |
Insulation resistance | min. 100 M&Omega at 200 V | |
Dielectric strength | 200 V AC, 60 Hz | |
Release point | &le max. 43 mm | |
Electrical specifications | ||
Electrical rating | AC supply: 10 VA, 132 V AC, 750 mA DC supply: 10 W, 100 V DC, 300 mA | |
Ambient conditions | ||
Ambient temperature | -40 ... 125 °C (-40 ... 257 °F) | |
Mechanical specifications | ||
Connection type | cable PVDF , 914 mm according to Mil-W-81044/9 | |
Core cross-section | 0.5 mm2 | |
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP68 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Reed Contact | |
Rated operating distance | 19.8 mm | |
Installation | non-flush | |
Output polarity | AC/DC | |
Mechanical life | 3 x 107 operations | |
Nominal ratings | ||
Operating voltage | 100 V DC, 250 mA 115 V AC, 250 mA | |
Hysteresis | &ge2.54 mm | |
Contact resistance | 0.15 &Omega | |
Insulation resistance | min. 100 M&Omega at 200 V | |
Dielectric strength | 200 V AC, 60 Hz | |
Release point | &le max. 43 mm | |
Electrical specifications | ||
Electrical rating | AC supply: 10 VA, 132 V AC, 750 mA DC supply: 10 W, 100 V DC, 300 mA | |
Ambient conditions | ||
Ambient temperature | -40 ... 125 °C (-40 ... 257 °F) | |
Mechanical specifications | ||
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP68 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | DC | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Hysteresis | 5 ... 25 % | |
Short-circuit protection | yes | |
Voltage drop | &le 2.5 V DC | |
Repeat accuracy | +/- 3 % | |
Operating current | &le 200 mA | |
Off-state current | &le 30 mA | |
No-load supply current | &le 40 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 10 - 30 V DC | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | DC | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Hysteresis | 5 ... 25 % | |
Short-circuit protection | yes | |
Voltage drop | &le 2.5 V DC | |
Repeat accuracy | +/- 3 % | |
Operating current | &le 200 mA | |
Off-state current | &le 30 mA | |
No-load supply current | &le 40 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 10 - 30 V DC | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NPN | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | DC | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Hysteresis | 5 ... 25 % | |
Short-circuit protection | yes | |
Voltage drop | &le 2.5 V DC | |
Repeat accuracy | +/- 3 % | |
Operating current | &le 200 mA | |
Off-state current | &le 30 mA | |
No-load supply current | &le 40 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 10 - 30 V DC | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NPN | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | DC | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Hysteresis | 5 ... 25 % | |
Short-circuit protection | yes | |
Voltage drop | &le 2.5 V DC | |
Repeat accuracy | +/- 3 % | |
Operating current | &le 200 mA | |
Off-state current | &le 30 mA | |
No-load supply current | &le 40 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 10 - 30 V DC | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | AC | |
Nominal ratings | ||
Operating voltage | 93 ... 132 V AC | |
Hysteresis | 5 ... 25 % | |
Voltage drop | 6 V at 500 mA | |
Momentary current (20 ms, 0.1 Hz) | 1.2 A | |
Repeat accuracy | +/- 3 % | |
Operating current | max. 500 mA | |
Off-state current | &le 1.5 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 93 - 132 V AC | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | AC | |
Nominal ratings | ||
Operating voltage | 93 ... 132 V AC | |
Hysteresis | 5 ... 25 % | |
Short-circuit protection | NO | |
Voltage drop | 6 V at 500 mA | |
Momentary current (20 ms, 0.1 Hz) | 1.2 A | |
Repeat accuracy | +/- 3 % | |
Operating current | max. 500 mA | |
Off-state current | &le 1.5 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 93 - 132 V AC | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 3 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | AC | |
Nominal ratings | ||
Operating voltage | 93 ... 132 V AC | |
Hysteresis | 5 ... 25 % | |
Voltage drop | 6 V at 500 mA | |
Momentary current (20 ms, 0.1 Hz) | 1.2 A | |
Repeat accuracy | +/- 3 % | |
Operating current | max. 500 mA | |
Off-state current | &le 1.5 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 93 - 132 V AC | |
Ambient conditions | ||
Ambient temperature | -30 ... 85 °C (-22 ... 185 °F) | |
Mechanical specifications | ||
Connection type | M12 connector, male, 4-pin, B-coded | |
Housing material | PBT | |
Sensing face | PBT | |
Housing diameter | ||
Degree of protection | IP67 | |
Note | no connection pin 3 and pin 4 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Two-wire | |
Rated operating distance | Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm | |
Installation | non-flush | |
Output polarity | AC | |
Nominal ratings | ||
Operating voltage | 24 V AC | |
Voltage drop | 8 V at 500 mA | |
Operating current | max. 500 mA | |
Off-state current | 1.5 mA | |
Indicators/operating means | ||
LED indicator | switching state | |
Electrical specifications | ||
Electrical rating | 24 V AC | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Polycarbonate | |
Sensing face | Polycarbonate | |
Housing diameter | ||
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Reed Contact | |
Rated operating distance | 12.7 mm | |
Installation | non-flush | |
Mechanical life | 5 x 107 switching cycles | |
Nominal ratings | ||
Switching frequency | 100 Hz | |
Repeat accuracy | &le 0.13 mm | |
No-load supply current | &le 50 mA | |
Reed bounce time | max. 0.5 ms | |
Electrical specifications | ||
Electrical rating | AC supply: 15 VA, 500 mA, 280 V RMS DC supply: 15 W, 500 mA, 400 V DC | |
Ambient conditions | ||
Ambient temperature | -20 ... 83 °C (-4 ... 181.4 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 1.83 m | |
Core cross-section | 1.5 mm2 | |
Housing material | aluminum | |
Sensing face | aluminum | |
Housing diameter | ||
Degree of protection | IP68 | |
Note | Full sensing range available for low carbon steel 25.4 x 76.2 x 6.35mm |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Reed Contact | |
Rated operating distance | 11.4 mm | |
Installation | non-flush | |
Output polarity | AC/DC | |
Mechanical life | 3 x 107 operations | |
Nominal ratings | ||
Operating voltage | 100 V DC, 250 mA 115 V AC, 250 mA | |
Hysteresis | &ge2.54 mm | |
Contact resistance | 0.2 &Omega | |
Insulation resistance | min. 100 M&Omega at 200 V DC | |
Dielectric strength | 200 V AC, 60 Hz | |
Release point | max. 17.8 mm | |
Electrical specifications | ||
Electrical rating | AC supply: 10 VA, 132 V AC, 750 mA DC supply: 10 W, 100 V DC, 300 mA | |
Ambient conditions | ||
Ambient temperature | -40 ... 125 °C (-40 ... 257 °F) | |
Mechanical specifications | ||
Connection type | cable PVDF , 914 mm | |
Core cross-section | 0.5 mm2 | |
Housing material | Phenolic | |
Sensing face | Phenolic | |
Housing diameter | ||
Degree of protection | IP68 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | Reed Contact | |
Rated operating distance | 19.1 mm | |
Installation | non-flush | |
Mechanical life | 5 x 107 switching cycles | |
Nominal ratings | ||
Switching frequency | 100 Hz | |
Repeat accuracy | &le 0.13 mm | |
No-load supply current | &le 50 mA | |
Reed bounce time | max. 0.5 ms | |
Electrical specifications | ||
Electrical rating | AC supply: 15 VA, 500 mA, 280 V RMS DC supply: 15 W, 500 mA, 400 V DC | |
Standard conformity | ||
Standards | EN 60947-5-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 83 °C (-4 ... 181.4 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 1.83 m | |
Core cross-section | 1.5 mm2 | |
Housing material | aluminum | |
Sensing face | aluminum | |
Housing diameter | ||
Degree of protection | IP68 | |
Note | Full sensing range available for low carbon steel 25.4 x 76.2 x 6.35mm |
General specifications | ||
---|---|---|
Switching function | complementary | |
Output type | PNP | |
Installation | on the cylinder | |
Output polarity | DC | |
Switching range | typ. 50 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 1.5 V | |
Operating current | 0 ... 100 mA | |
No-load supply current | &le 30 mA | |
Functional safety related parameters | ||
MTTFd | 739 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED indicator | red: switching state output 1 yellow: switching state output 2 | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.5 mm2 | |
Housing material | Polyamide (PA) | |
Sensing face | Polyamide (PA) | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | complementary | |
Output type | PNP | |
Installation | on the cylinder | |
Output polarity | DC | |
Switching range | typ. 50 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 1.5 V | |
Operating current | 0 ... 100 mA | |
No-load supply current | &le 30 mA | |
Functional safety related parameters | ||
MTTFd | 739 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
LED indicator | red: switching state output 1 yellow: switching state output 2 | |
Approvals and certificates | ||
EAC conformity | TR CU 020/2011 | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | Polyamide (PA) | |
Sensing face | Polyamide (PA) | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 60 mm | |
Installation | flush in non-magnetic metal | |
Output polarity | DC | |
Assured operating distance | 10 ... 48.6 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2.5 V | |
Operating current | 0 ... 200 mA | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 2935 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
Protection class | II | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | stainless steel 1.4404 / AISI 316L | |
Sensing face | PBT | |
Housing diameter | 12 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 60 mm | |
Installation | flush in non-magnetic metal | |
Output polarity | DC | |
Assured operating distance | 10 ... 48.6 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2.5 V | |
Operating current | 0 ... 200 mA | |
No-load supply current | &le 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 3909 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
Protection class | III | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
Mechanical specifications | ||
Connection type | cable PUR , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | stainless steel 1.4404 / AISI 316L | |
Sensing face | PBT | |
Housing diameter | 8 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 60 mm | |
Installation | flush in non-magnetic metal | |
Output polarity | DC | |
Assured operating distance | 10 ... 48.6 mm | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2.5 V | |
Operating current | 0 ... 200 mA | |
No-load supply current | &le 10 mA | |
Switching state indicator | Multihole-LED, yellow | |
Functional safety related parameters | ||
MTTFd | 3909 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
Protection class | III | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
Mechanical specifications | ||
Connection type | Connector M8 x 1 , 3-pin | |
Housing material | stainless steel 1.4404 / AISI 316L | |
Sensing face | PBT | |
Housing diameter | 8 mm | |
Degree of protection | IP67 |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 60 mm | |
Installation | flush in non-magnetic metal | |
Assured operating distance | 10 ... 48.6 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 5000 Hz | |
Current consumption | ||
Magnet detected | &ge 2.5 mA | |
Magnet not detected | &le 1 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 4382 a | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | stainless steel 1.4404 / AISI 316L | |
Sensing face | stainless steel 1.4404 / AISI 316L | |
Degree of protection | IP66 / IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 60 mm | |
Installation | flush in non-magnetic metal | |
Assured operating distance | 10 ... 48.6 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 5000 Hz | |
Current consumption | ||
Magnet detected | &ge 2.5 mA | |
Magnet not detected | &le 1 mA | |
Switching state indicator | LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | stainless steel 1.4404 / AISI 316L | |
Sensing face | stainless steel 1.4404 / AISI 316L | |
Degree of protection | IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 35 mm | |
Installation | flush | |
Assured operating distance | 0 ... 35 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 5000 Hz | |
Current consumption | ||
Magnet detected | &ge 3 mA | |
Magnet not detected | &le 1 mA | |
Switching state indicator | LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | anodized aluminum | |
Sensing face | PBT | |
Degree of protection | IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 35 mm | |
Installation | flush | |
Assured operating distance | 0 ... 35 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
Switching frequency | 0 ... 1000 Hz | |
Current consumption | ||
Magnet detected | &ge 3 mA | |
Magnet not detected | &le 1 mA | |
Switching state indicator | LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165F | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.34 mm2 | |
Housing material | anodized aluminum | |
Sensing face | PBT | |
Degree of protection | IP67 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 60 mm | |
Installation | flush | |
Output polarity | DC | |
Actuating element | magnetic | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 5000 Hz | |
Hysteresis | 1 ... 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2.5 V DC | |
Operating current | &le 200 mA | |
Current consumption | < 10 mA | |
Indicators/operating means | ||
Operation indicator | 4-way LED | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
Mechanical specifications | ||
Connection type | V1 connector (M12 x 1), 4-pin | |
Housing material | stainless steel V4A | |
Sensing face | stainless steel V4A | |
Housing diameter | 12 mm | |
Degree of protection | IP65 / IP67 / |
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 60 mm | |
Installation | flush | |
Output polarity | DC | |
Actuating element | magnetic | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 5000 Hz | |
Hysteresis | 1 ... 10 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le 2.5 V DC | |
Operating current | &le 100 mA | |
Current consumption | < 10 mA | |
Indicators/operating means | ||
Operation indicator | 4-way LED | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le36 V | |
Ambient conditions | ||
Ambient temperature | 0 ... 100 °C (32 ... 212 °F) | |
Mechanical specifications | ||
Connection type | V1 connector (M12 x 1), 4-pin | |
Housing material | stainless steel V4A | |
Sensing face | stainless steel V4A | |
Housing diameter | 12 mm | |
Degree of protection | IP65 / IP68 / IP69K / |