Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
Описание оборудования | ||
---|---|---|
Pressure relief vent for use with the Pepperl+Fuchs Bebco EPS® purge and pressurization systems |
Описание оборудования | ||
---|---|---|
3003 Series purge and pressurization system |
Описание оборудования | ||
---|---|---|
3004 Series purge and pressurization system |
Описание оборудования | ||
---|---|---|
Ex pz purge system for Zone 2 and 22 |
General specifications | ||
---|---|---|
Number of volume exchanges | min. 5 | |
Hazardous environment | gas or dust | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Maximum pressure | 25 mbar (10" H2O) | |
Safe pressure | - gas 0.25 mbar (0.1" H2O) (Zone 2) - dust 0.5 mbar (0.2" H2O) (Zone 22) | |
Purge flow and enclosure pressure rate | - for 3.0 mm orifice at 2 bar (29 psig): 105 l/min, 8 ... 10 mbar - for 4.5 mm orifice at 2 bar (29 psig): 220 l/min, 8 ... 10 mbar | |
Flow rate for leakage compensation | 0.3 l/min typ. (enclosure pressure at 1 mbar, depends on enclosure seal) | |
Breaking pressure | 3 mbar (1.2" H2O) | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | 5 ... 95 %, noncondensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Material | ||
Housing | polyester | |
Spark arrestor | Stainless steel (multi screen) | |
Installation | - any orientation to enclosure - not gravity dependent - internal and external mounting possible | |
Mass | approx. 320 g (0.7 lb) | |
Dimensions | 66 x 111 x 55 mm (2.6 x 4.4 x 2.2 inch) | |
Mounting | mounting hole 37 mm with locking ring | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | EPS 10 ATEX 1263 , for additional certificates see www.pepperl-fuchs.com | |
Group, category, type of protection, temperature class | II 3 G Ex nA nC [pz] II T4 -20 °C to +60 °C II 3 G Ex nA nC [pz] II T6 -20 °C to +40 °C II 3 D Ex tD A22 [pD] IP64 T70°C | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006 |
Supply | ||
---|---|---|
Rated voltage | 230 VAC - 230 VAC ± 10 % 115 VAC - 115 VAC ± 10% 24 VDC - 24 VDC ± 10% | |
Power consumption | 230 VAC - 230 VAC @ 5 W 115 VAC - 115 VAC @ 6 W 24 VDC - 24 VDC @ 8 W | |
Ambient conditions | ||
Ambient temperature | -10 ... 60 °C (14 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP65 | |
Material | body: brass valve (internal): brass seal: NBR |
Ambient conditions | ||
---|---|---|
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Mechanical specifications | ||
Material | body: Grivory® (PA66) seal: NBR |
General specifications | ||
---|---|---|
Operating mode | automatic purging | |
Hazardous environment | gas or dust | |
Supply | ||
Rated power | 24 VDC: 2.6 W 3.1 VA, 50...60 Hz 3.0 VA, 50...60 Hz Voltage tolerance: +/-10% | |
Electrical specifications | ||
Fuse rating | DC: 500 mA AC: 80 mA (fuse rating on 5500 control unit) | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 1.7 bar (25 psi) to 8.0 bar (115 psi) | |
Purge flow rate | solenoid valve : Cv (flow coefficient) = 1.4 needle valve : Cv (flow coefficient) = 0.25 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) T5 | |
Mechanical specifications | ||
Connection type | Pneumatic Input port: 3/8" Tube compression fitting Output port: 3/8" Tube compression fitting | |
Degree of protection | type 7 & 9 | |
Material | Housing: anodized aluminum 3/8" compression fittings: 316 stainless steel Pressure ports: 3/8" NPTF Bulkhead fitting: 316 stainless steel Mounting bolts: 1/4 - 20, 316 stainless steel Sealing washers: UL recognized type 4X | |
Cable | 3 m | |
Mass | 1250 g (2.8 lb) | |
Dimensions | see dimensions | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ||
Group, category, type of protection, temperature class | II 2 G Ex mb IIC T5 Gb II 2 D Ex mb tb IIIC T95C Db IP65 Protection by encapsulation PTB 03 ATEX 2018 X | |
International approvals | ||
IECEx approval | II 2 G Ex mb IIC T5 Gb II 2 D Ex mb tb IIIC T95C Db IP65 Protection by encapsulation IECEx PTB 04.0002X |
General specifications | ||
---|---|---|
Operating mode | automatic purging | |
Hazardous environment | gas or dust | |
Supply | ||
Rated power | 24 VDC: 4.6 W 120 VAC: 6.8 VA, 60 Hz 230 VAC: 6.8 VA, 60 Hz Voltage tolerance: +/-10% | |
Electrical specifications | ||
Fuse rating | DC: 500 mA AC: 80 mA (fuse rating on 5500 control unit) | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 1.4 bar (20 psi) to 8.2 bar (120 psi) | |
Purge flow rate | solenoid valve : Cv (flow coefficient) = 1.4 needle valve : Cv (flow coefficient) = 0.25 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Connection type | Pneumatic Input port: 3/8" Tube compression fitting Output port: 3/8" Tube compression fitting Electrical connection ½" NPTF thread connection w/ 24" (0.61m) flying leads | |
Degree of protection | type 7 & 9 | |
Material | Housing: anodized aluminum 3/8" compression fittings: 316 stainless steel Pressure ports: 3/8" NPTF Bulkhead fitting: 316 stainless steel Mounting bolts: 1/4 - 20, 316 stainless steel Sealing washers: UL recognized type 4X | |
Mass | 1250 g (2.8 lb) | |
Dimensions | see dimensions | |
International approvals | ||
FM approval | FM3006713 Explosion proof: Class I, Divison 1, Group A-D, T4, Ta = 60C DIP: Class II, Division 1, Groups F+G, T4, Ta = 60C Nonincendive: Class I, Division 2, Groups A-D, T4, Ta = 60C Suitable for Class II, Division 2, Groups F+G, T4, Ta = 60C | |
CSA approval | CSA 202633 Class I, Division 1, Groups A-D: Class II, Groups E,F,G Class I, Division 2, Groups A-D |
General specifications | ||
---|---|---|
Operating mode | automatic purging | |
Hazardous environment | gas or dust | |
Supply | ||
Rated power | 24 VDC: 5.6 W 120 VAC: 7.2 VA, 60 Hz 230 VAC: 7.2 VA, 60 Hz Voltage tolerance: +/-10% | |
Electrical specifications | ||
Fuse rating | DC: 500 mA AC: 80 mA (fuse rating on 5500 control unit) | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 1.4 bar (20 psi) to 8.2 bar (120 psi) | |
Purge flow rate | solenoid valve : Cv (flow coefficient) = 1.4 needle valve : Cv (flow coefficient) = 0.24 | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Mechanical specifications | ||
Connection type | Pneumatic Input port: 3/8" Tube compression fitting Output port: 3/8" Tube compression fitting Electrical connection ½" NPTF thread connection w/ 24" (0.61m) flying leads | |
Degree of protection | type 7 & 9 | |
Material | Housing: anodized aluminum 3/8" compression fittings: 316 stainless steel Pressure ports: 3/8" NPTF Bulkhead fitting: 316 stainless steel Mounting bolts: 1/4 - 20, 316 stainless steel Sealing washers: UL recognized type 4X | |
Mass | 1250 g (2.8 lb) | |
Dimensions | see dimensions | |
International approvals | ||
UL approval | ||
cULus | Class I Division 2, Group A-D Class II Division 2, Group F+G | |
CSA approval | Class I Division 2, Group A-D Class II Division 2, Group F+G |
General specifications | ||
---|---|---|
Hazardous environment | gas or dust | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Maximum pressure | depends on the integrity of the enclosure (strength) | |
Purge flow rate | See graphs | |
Flow rate for leakage compensation | EPV-5500....-01: approx. 21 scfh (593 l/hr) @ 0.25" w.c. (0.63 mbar) approx. 58 scfh (1640 l/hr) @ 0.75" w.c. (1.9 mbar) EPV-5500....-02: approx. 14 scfh (395 l/hr) @ 0.25" w.c. (0.63 mbar) approx. 34 scfh (961 l/hr) @ 0.75" w.c. (1.9 mbar) EPV-5500....-03: approx. 9.2 scfh (260 l/hr) @ 0.25" w.c. (0.63 mbar) approx. 22 scfh (622 l/hr) @ 0.75" w.c. (1.9 mbar) | |
Breaking pressure | EPV-5500....-01: 0.8" w.c. (2.0 mbar) EPV-5500....-02: 1.4" w.c. (3.5 mbar) EPV-5500....-03: 1.5" w.c. (3.8 mbar) | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Relative humidity | 5 ... 90 %, non-condensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Degree of protection | EPV-5500....-01/02: mounting only Type 4X EPV-5500....-03: Type 4X | |
Material | ||
Housing | EPV-5500-AA... body and cap: 6061T6 aluminum EPV-5500-SS... body: 6061T6 aluminum, cap: 316L stainless steel | |
Spark arrestor | 316L, (1.4404) stainless steel | |
Installation | - any orientation to enclosure - not gravity dependent - internal and external mounting possible | |
Mass | approx. 1005 g (2.2 lb) | |
Dimensions | see dimensions | |
Mounting | mounting hole 1 ½" NPT knockout (50.8mm) hole sealing nut (provided) | |
Data for application in connection with hazardous areas | ||
EC-Type Examination Certificate | ATEX UL / DEMKO 14 ATEX 1282X | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006 | |
International approvals | ||
UL approval | RFPW, E184741, RFPW7, E184741 | |
IECEx approval | IECEx UL/DEMKO 14.0019X |
General specifications | ||
---|---|---|
Operating mode | fully automatic (FA) | |
Number of volume exchanges | 4 ... 19 | |
Hazardous environment | gas or dust | |
Supply | ||
Rated voltage | 90 ... 264 V AC, 48 ... 62 Hz ±10 %, single phase 20 ... 30 V DC | |
Power consumption | 100 ... 240 V AC - 2.3 VA (without digital valve) 20 ... 30 V DC - 2.5 W (without digital valve) | |
Electrical specifications | ||
Fuse rating | AC: 2 A DC: 3.15 A | |
Input | ||
Input I | Temperature, up to 2 RTD's per unit | |
Connection | Pt100, 2-wire-connection | |
Input type | temperature input | |
Input II | 1 Bypass | |
Connection | passive contact (switch) | |
Input type | mechanical contact | |
Output | ||
Output I | ||
Connection | K1, terminals: K1/N0, K1/N0 | |
Output type | enclosure power, (1) SPST | |
Inrush current | 6 A | |
Contact loading | 6 A @ 250 V AC , 30 V DC resistive load, 6 A @ 30 V DC | |
Output II | ||
Connection | K2, terminals: K2(NO, C, NC) | |
Output type | alarm, (1) DPST | |
Inrush current | 3 A | |
Contact loading | 3 A @ 250 V AC , 30 V DC resistive load, 3 A @ 30 V DC | |
Output III | ||
Connection | digital valve, terminals SV | |
Output type | (1) SPDT, powered contacts from supply 0.08 A @ 250 VAC 0.5 A @ 30 VDC | |
Inrush current | 3 A | |
Indicators/settings | ||
LED indicator | Membrane Pad K1: Green - Contact K1 is energized K2: Amber - Contact K2 is energized SV1/encl press.: Blue for safe pressure, Amber for valve on Bypass: Amber when bypass is active PT100 error: Red when fault in PT100 sensor | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Safe pressure | - gas 0.7 mbar (0.3" H2O) - dust 1.6 mbar (0.65" H2O) | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 40 °C (-4 ... 104 °F) at T6 -20 ... 60 °C (-4 ... 140 °F) at T4 | |
Relative humidity | 5 ... 90 %, non-condensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Connection type | High pressure port: 1/8" NPTF Low pressure port: 1/8" NPTF | |
Cable gland | Wire size M12 diameter 3 - 6.5mm M20 diameter 10 - 14mm RTD/Bypass: (3) M12x1.5 K1, K2, SV1: 'P_C' (3) M20x1.5 | |
Degree of protection | Type 4X, IP66 | |
Material | Housing: 316 stainless steel Cable Gland: 316 stainless steel or Nickel Plated Brass Pressure Ports: 316 stainless steel Membrane Pad: Autotex F200XE O-ring: EPDM | |
Mass | approx. 2.7 kg (6 lb) | |
Dimensions | 165 x 124 x 90 mm (6.5 x 4.9 x 3.5 inch) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | ||
Marking | external II 3 G Ex ic nA nC [ic pz IIC Gc] IIC T4 [Gc] (-20°C to 60°C) II 3 G Ex ic nA nC [ic pz IIC Gc] IIC T6 [Gc] (-20°C to 40°C) II 3 D Ex ic tc [ic pD IIIC Dc] IIIB T80°C Dc (-20°C to 60°C) II 3 D Ex ic tc [ic pD IIIC Dc] IIIB T60°C Dc (-20°C to 40°C) internal II 3 G Ex ic nA nC [ic pz IIC] IIC T4 [Gc] (-20°C to 60°C) II 3 G Ex ic nA nC [ic pz IIC] IIC T6 [Gc] (-20°C to 40°C) II 3 D Ex ic tc [ic pD IIIC Dc] IIIC T80°C Dc (-20°C to 60°C) II 3 D Ex ic tc [ic pD IIIC Dc] IIIC T60°C Dc (-20°C to 40°C) | |
Directive conformity | ||
Directive 94/9/EC | EN 60079-0:2012+A11:2013 , EN 60079-2:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2009 , EN 61241-4:2006 | |
International approvals | ||
UL approval | ||
cULus | Class I Division 2 Group A-D T4 (-20°C to 60°C) Class I Division 2 Group A-D T6 (-20°C to 40°C) Class II Division 2 Group F+G T4 (-20°C to 60°C) Class II Division 2 Group F+G T6 (-20°C to 40°C) | |
IECEx approval | Ex ic nA nC [ic pz IIC Gc] IIC T4 Gc (-20 °C to 60 °C) Ex ic nA nC [ic pz IIC Gc] IIC T6 Gc (-20 °C to 40 °C) Ex ic tc [ic pD IIIC Dc] IIIB T80°C Dc (-20 °C to 60 °C) External version Ex ic tc [ic pD IIIC Dc] IIIB T60°C Dc (-20 °C to 40 °C) External version Ex ic tc [ic pD IIIC Dc] IIIC T80°C Dc (-20 °C to 60 °C) Internal version Ex ic tc [ic pD IIIC Dc] IIIC T60°C Dc (-20 °C to 40 °C) Internal version |