Каталожный номер: 515455
Описание оборудования
Pressure relief vent for use with the Pepperl+Fuchs Bebco EPS® purge and pressurization systems
Узнать цену
Каталожный номер: T154962
Описание оборудования
3003 Series purge and pressurization system
Узнать цену
Каталожный номер: T156348
Описание оборудования
3004 Series purge and pressurization system
Узнать цену
Каталожный номер: 514730
Описание оборудования
Ex pz purge system for Zone 2 and 22
Узнать цену
Каталожный номер: 514731
General specifications
Number of volume exchangesmin. 5
Hazardous environmentgas or dust
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Maximum pressure25 mbar (10" H2O)
Safe pressure- gas 0.25 mbar (0.1" H2O) (Zone 2)
- dust 0.5 mbar (0.2" H2O) (Zone 22)
Purge flow and enclosure pressure rate- for 3.0 mm orifice at 2 bar (29 psig): 105 l/min, 8 ... 10 mbar
- for 4.5 mm orifice at 2 bar (29 psig): 220 l/min, 8 ... 10 mbar
Flow rate for leakage compensation0.3 l/min typ. (enclosure pressure at 1 mbar, depends on enclosure seal)
Breaking pressure3 mbar (1.2" H2O)
Conformity
Degree of protectionEN 60529
Shock resistanceEN 60068-2
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity5 ... 95 %, noncondensing
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance30 g, 11 ms, all axes
Mechanical specifications
Material
Housingpolyester
Spark arrestorStainless steel (multi screen)
Installation- any orientation to enclosure
- not gravity dependent
- internal and external mounting possible
Massapprox. 320 g (0.7 lb)
Dimensions66 x 111 x 55 mm (2.6 x 4.4 x 2.2 inch)
Mountingmounting hole 37 mm with locking ring
Data for application in connection with hazardous areas
EC-Type Examination CertificateEPS 10 ATEX 1263 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection, temperature classEx-Hexagon II 3 G Ex nA nC [pz] II T4 -20 °C to +60 °C
Ex-Hexagon II 3 G Ex nA nC [pz] II T6 -20 °C to +40 °C
Ex-Hexagon II 3 D Ex tD A22 [pD] IP64 T70°C
Directive conformity
Directive 94/9/ECEN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006
Узнать цену
Каталожный номер: 514728
Supply
Rated voltage230 VAC - 230 VAC ± 10 %
115 VAC - 115 VAC ± 10%
24 VDC - 24 VDC ± 10%
Power consumption230 VAC - 230 VAC @ 5 W
115 VAC - 115 VAC @ 6 W
24 VDC - 24 VDC @ 8 W
Ambient conditions
Ambient temperature-10 ... 60 °C (14 ... 140 °F)
Mechanical specifications
Degree of protectionIP65
Materialbody: brass
valve (internal): brass
seal: NBR
Узнать цену
Каталожный номер: 514729
Ambient conditions
Ambient temperature-10 ... 50 °C (14 ... 122 °F)
Mechanical specifications
Materialbody: Grivory® (PA66)
seal: NBR
Узнать цену
Каталожный номер: T169982
General specifications
Operating modeautomatic purging
Hazardous environmentgas or dust
Supply
Rated power24 VDC: 2.6 W
3.1 VA, 50...60 Hz
3.0 VA, 50...60 Hz
Voltage tolerance: +/-10%
Electrical specifications
Fuse ratingDC: 500 mA
AC: 80 mA
(fuse rating on 5500 control unit)
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement1.7 bar (25 psi) to 8.0 bar (115 psi)
Purge flow ratesolenoid valve : Cv (flow coefficient) = 1.4
needle valve : Cv (flow coefficient) = 0.25
Ambient conditions
Ambient temperature-20 ... 50 °C (-4 ... 122 °F) T5
Mechanical specifications
Connection typePneumatic
Input port: 3/8" Tube compression fitting
Output port: 3/8" Tube compression fitting

Degree of protectiontype 7 & 9
Material
Housing: anodized aluminum
3/8" compression fittings: 316 stainless steel
Pressure ports: 3/8" NPTF
Bulkhead fitting: 316 stainless steel
Mounting bolts: 1/4 - 20, 316 stainless steel
Sealing washers: UL recognized type 4X
Cable3 m
Mass1250 g (2.8 lb)
Dimensionssee dimensions
Data for application in connection with hazardous areas
EC-Type Examination Certificate
Group, category, type of protection, temperature classEx-Hexagon II 2 G Ex mb IIC T5 Gb
Ex-Hexagon II 2 D Ex mb tb IIIC T95C Db IP65
Protection by encapsulation

PTB 03 ATEX 2018 X
International approvals
IECEx approvalEx-Hexagon II 2 G Ex mb IIC T5 Gb
Ex-Hexagon II 2 D Ex mb tb IIIC T95C Db IP65
Protection by encapsulation
IECEx PTB 04.0002X
Узнать цену
Каталожный номер: T169984
General specifications
Operating modeautomatic purging
Hazardous environmentgas or dust
Supply
Rated power24 VDC: 4.6 W
120 VAC: 6.8 VA, 60 Hz
230 VAC: 6.8 VA, 60 Hz
Voltage tolerance: +/-10%
Electrical specifications
Fuse ratingDC: 500 mA
AC: 80 mA
(fuse rating on 5500 control unit)
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement1.4 bar (20 psi) to 8.2 bar (120 psi)
Purge flow ratesolenoid valve : Cv (flow coefficient) = 1.4
needle valve : Cv (flow coefficient) = 0.25
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Connection typePneumatic
Input port: 3/8" Tube compression fitting
Output port: 3/8" Tube compression fitting

Electrical connection
½" NPTF thread connection w/ 24" (0.61m) flying leads
Degree of protectiontype 7 & 9
Material
Housing: anodized aluminum
3/8" compression fittings: 316 stainless steel
Pressure ports: 3/8" NPTF
Bulkhead fitting: 316 stainless steel
Mounting bolts: 1/4 - 20, 316 stainless steel
Sealing washers: UL recognized type 4X
Mass1250 g (2.8 lb)
Dimensionssee dimensions
International approvals
FM approvalFM3006713
Explosion proof: Class I, Divison 1, Group A-D, T4, Ta = 60C
DIP: Class II, Division 1, Groups F+G, T4, Ta = 60C
Nonincendive: Class I, Division 2, Groups A-D, T4, Ta = 60C

Suitable for Class II, Division 2, Groups F+G, T4, Ta = 60C
CSA approvalCSA 202633
Class I, Division 1, Groups A-D: Class II, Groups E,F,G
Class I, Division 2, Groups A-D
Узнать цену
Каталожный номер: T169983
General specifications
Operating modeautomatic purging
Hazardous environmentgas or dust
Supply
Rated power24 VDC: 5.6 W
120 VAC: 7.2 VA, 60 Hz
230 VAC: 7.2 VA, 60 Hz
Voltage tolerance: +/-10%
Electrical specifications
Fuse ratingDC: 500 mA
AC: 80 mA
(fuse rating on 5500 control unit)
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement1.4 bar (20 psi) to 8.2 bar (120 psi)
Purge flow ratesolenoid valve : Cv (flow coefficient) = 1.4
needle valve : Cv (flow coefficient) = 0.24
Ambient conditions
Ambient temperature-20 ... 50 °C (-4 ... 122 °F)
Mechanical specifications
Connection typePneumatic
Input port: 3/8" Tube compression fitting
Output port: 3/8" Tube compression fitting

Electrical connection
½" NPTF thread connection w/ 24" (0.61m) flying leads
Degree of protectiontype 7 & 9
Material
Housing: anodized aluminum
3/8" compression fittings: 316 stainless steel
Pressure ports: 3/8" NPTF
Bulkhead fitting: 316 stainless steel
Mounting bolts: 1/4 - 20, 316 stainless steel
Sealing washers: UL recognized type 4X
Mass1250 g (2.8 lb)
Dimensionssee dimensions
International approvals
UL approval
cULusClass I Division 2, Group A-D
Class II Division 2, Group F+G
CSA approvalClass I Division 2, Group A-D
Class II Division 2, Group F+G
Узнать цену
Каталожный номер: T169761
General specifications
Hazardous environmentgas or dust
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Maximum pressuredepends on the integrity of the enclosure (strength)
Purge flow rateSee graphs
Flow rate for leakage compensationEPV-5500....-01:
approx. 21 scfh (593 l/hr) @ 0.25" w.c. (0.63 mbar)
approx. 58 scfh (1640 l/hr) @ 0.75" w.c. (1.9 mbar)
EPV-5500....-02:
approx. 14 scfh (395 l/hr) @ 0.25" w.c. (0.63 mbar)
approx. 34 scfh (961 l/hr) @ 0.75" w.c. (1.9 mbar)
EPV-5500....-03:
approx. 9.2 scfh (260 l/hr) @ 0.25" w.c. (0.63 mbar)
approx. 22 scfh (622 l/hr) @ 0.75" w.c. (1.9 mbar)
Breaking pressureEPV-5500....-01: 0.8" w.c. (2.0 mbar)
EPV-5500....-02: 1.4" w.c. (3.5 mbar)
EPV-5500....-03: 1.5" w.c. (3.8 mbar)
Conformity
Degree of protectionEN 60529
Shock resistanceEN 60068-2
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity5 ... 90 %, non-condensing
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance30 g, 11 ms, all axes
Mechanical specifications
Degree of protectionEPV-5500....-01/02: mounting only Type 4X
EPV-5500....-03: Type 4X
Material
HousingEPV-5500-AA... body and cap: 6061T6 aluminum
EPV-5500-SS... body: 6061T6 aluminum, cap: 316L stainless steel
Spark arrestor316L, (1.4404) stainless steel
Installation- any orientation to enclosure
- not gravity dependent
- internal and external mounting possible
Massapprox. 1005 g (2.2 lb)
Dimensionssee dimensions
Mountingmounting hole 1 ½" NPT knockout (50.8mm) hole sealing nut (provided)
Data for application in connection with hazardous areas
EC-Type Examination CertificateATEX UL / DEMKO 14 ATEX 1282X
Directive conformity
Directive 94/9/ECEN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006
International approvals
UL approvalRFPW, E184741, RFPW7, E184741
IECEx approvalIECEx UL/DEMKO 14.0019X

Узнать цену
Каталожный номер: T167146
General specifications
Operating modefully automatic (FA)
Number of volume exchanges4 ... 19
Hazardous environmentgas or dust
Supply
Rated voltage90 ... 264 V AC, 48 ... 62 Hz ±10 %, single phase
20 ... 30 V DC
Power consumption100 ... 240 V AC - 2.3 VA (without digital valve)
20 ... 30 V DC - 2.5 W (without digital valve)
Electrical specifications
Fuse ratingAC: 2 A
DC: 3.15 A
Input
Input ITemperature, up to 2 RTD's per unit
ConnectionPt100, 2-wire-connection
Input typetemperature input
Input II1 Bypass
Connectionpassive contact (switch)
Input typemechanical contact
Output
Output I
ConnectionK1, terminals: K1/N0, K1/N0
Output typeenclosure power, (1) SPST
Inrush current6 A
Contact loading6 A @ 250 V AC , 30 V DC resistive load, 6 A @ 30 V DC
Output II
ConnectionK2, terminals: K2(NO, C, NC)
Output typealarm, (1) DPST
Inrush current3 A
Contact loading3 A @ 250 V AC , 30 V DC resistive load, 3 A @ 30 V DC
Output III
Connectiondigital valve, terminals SV
Output type(1) SPDT, powered contacts from supply
0.08 A @ 250 VAC
0.5 A @ 30 VDC
Inrush current3 A
Indicators/settings
LED indicatorMembrane Pad
K1: Green - Contact K1 is energized
K2: Amber - Contact K2 is energized
SV1/encl press.: Blue for safe pressure, Amber for valve on
Bypass: Amber when bypass is active
PT100 error: Red when fault in PT100 sensor
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Safe pressure- gas 0.7 mbar (0.3" H2O)
- dust 1.6 mbar (0.65" H2O)
Conformity
Degree of protectionEN 60529
Shock resistanceEN 60068-2
Ambient conditions
Ambient temperature-20 ... 40 °C (-4 ... 104 °F) at T6
-20 ... 60 °C (-4 ... 140 °F) at T4
Relative humidity5 ... 90 %, non-condensing
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance30 g, 11 ms, all axes
Mechanical specifications
Connection typeHigh pressure port: 1/8" NPTF
Low pressure port: 1/8" NPTF
Cable glandWire size
M12 diameter 3 - 6.5mm
M20 diameter 10 - 14mm
RTD/Bypass: (3) M12x1.5
K1, K2, SV1: 'P_C' (3) M20x1.5
Degree of protectionType 4X, IP66
MaterialHousing: 316 stainless steel
Cable Gland: 316 stainless steel or Nickel Plated Brass
Pressure Ports: 316 stainless steel
Membrane Pad: Autotex F200XE
O-ring: EPDM
Massapprox. 2.7 kg (6 lb)
Dimensions165 x 124 x 90 mm (6.5 x 4.9 x 3.5 inch)
Data for application in connection with hazardous areas
EU-Type Examination Certificate
Markingexternal
Ex-Hexagon II 3 G Ex ic nA nC [ic pz IIC Gc] IIC T4 [Gc] (-20°C to 60°C)
Ex-Hexagon II 3 G Ex ic nA nC [ic pz IIC Gc] IIC T6 [Gc] (-20°C to 40°C)
Ex-Hexagon II 3 D Ex ic tc [ic pD IIIC Dc] IIIB T80°C Dc (-20°C to 60°C)
Ex-Hexagon II 3 D Ex ic tc [ic pD IIIC Dc] IIIB T60°C Dc (-20°C to 40°C)
internal
Ex-Hexagon II 3 G Ex ic nA nC [ic pz IIC] IIC T4 [Gc] (-20°C to 60°C)
Ex-Hexagon II 3 G Ex ic nA nC [ic pz IIC] IIC T6 [Gc] (-20°C to 40°C)
Ex-Hexagon II 3 D Ex ic tc [ic pD IIIC Dc] IIIC T80°C Dc (-20°C to 60°C)
Ex-Hexagon II 3 D Ex ic tc [ic pD IIIC Dc] IIIC T60°C Dc (-20°C to 40°C)
Directive conformity
Directive 94/9/ECEN 60079-0:2012+A11:2013 , EN 60079-2:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2009 , EN 61241-4:2006
International approvals
UL approval
cULusClass I Division 2 Group A-D T4 (-20°C to 60°C)
Class I Division 2 Group A-D T6 (-20°C to 40°C)
Class II Division 2 Group F+G T4 (-20°C to 60°C)
Class II Division 2 Group F+G T6 (-20°C to 40°C)
IECEx approvalEx ic nA nC [ic pz IIC Gc] IIC T4 Gc (-20 °C to 60 °C)
Ex ic nA nC [ic pz IIC Gc] IIC T6 Gc (-20 °C to 40 °C)
Ex ic tc [ic pD IIIC Dc] IIIB T80°C Dc (-20 °C to 60 °C) External version
Ex ic tc [ic pD IIIC Dc] IIIB T60°C Dc (-20 °C to 40 °C) External version
Ex ic tc [ic pD IIIC Dc] IIIC T80°C Dc (-20 °C to 60 °C) Internal version
Ex ic tc [ic pD IIIC Dc] IIIC T60°C Dc (-20 °C to 40 °C) Internal version
Узнать цену
Добавлено в корзину!

Товаров: 0

На сумму: 0

Продолжить покупки
Оформить заказ

Ex pz Purge System Pepperl+Fuchs (розничные и оптовые цены)

Клиенты

Блог

Подписка

Последнее на форуме

ООО "Зипстор"
127282, Страна, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru