Каталожный номер: 915362
Supply
Rated voltage7 ... 32 V DC
Rated current< 1 mA , max. 25 mA
Electrical specifications
Output rated operating current3.2 ... 25 mA
Supplyloop power for field devices
voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V
Input
Connection- 5 wires, 600 mm long, exiting from male thread NPT1/2
- 1 external grounding point
HART communication
ProtocolHART 7.1, backward compatible
Number of devicesup to 8 HART field devices (depending on installation)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013+A11:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300 328 V1.8.1:2012
EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012-09
Conformity
Degree of protectionIEC 60529:2013
Ambient conditions
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
MaterialAluminum alloy with polyurethane enamel paint
Mass460 g
Dimensions60.8 x 60.8 x 100 mm (l x w x h)
Data for application in connection with hazardous areas
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
Узнать цену
Каталожный номер: 915361
Supply
Rated voltage7 ... 30 V DC
Rated current< 1 mA , max. 25 mA
Electrical specifications
Output rated operating current3.2 ... 25 mA
Supplyloop power for field devices
voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V
Input
Connection- 5 wires, 600 mm long, exiting from male thread NPT1/2
- 1 external grounding point
HART communication
ProtocolHART 7.1, backward compatible
Number of devicesup to 8 HART field devices (depending on installation)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013+A11:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300 328 V1.8.1:2012
EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012-09
Conformity
Degree of protectionIEC 60529:2013
Ambient conditions
Ambient temperaturetemperature class T5: -40 ... 85 °C (-40 ... 185 °F)
temperature class T6: -40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
MaterialAluminum alloy with polyurethane enamel paint
Mass460 g
Dimensions60.8 x 60.8 x 100 mm (l x w x h)
Data for application in connection with hazardous areas
EU-Type Examination CertificateFM 11 ATEX 0019 X
MarkingEx-Hexagon II 1 G Ex ia IIC T6/T5 Ga
Ex-Hexagon II 1 D Ex ia IIIC T95 °C Da
CertificateFM 11 ATEX 0068 X
MarkingEx-Hexagon II 3 G Ex nA IIC T6/T5 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approvalCoC3040786(C)
Approved forClass I, Zone 0, (A)Ex ia IIC T6/T5 Ga
Class I, Zone 2, (A)Ex nA IIC T6/T5 Gc
Class I, Zone 20, (A)Ex ia IIIC T95°C Da
Class I, Division 1, Groups A - D
Class II, Division 1, Groups E - G
Class III
Class I, Division 2, Groups A - D
IECEx approvalIECEx FMG 11.0010X
Approved forEx ia IIC T6/T5 Ga
Ex nA IIC T6/T5 Gc
Ex ia IIIC T95°C Da
StandardsIEC 60079-0:2011 , IEC 60079-11:2011 , IEC 60079-15:2010
Узнать цену
Каталожный номер: 915838
Supply
Rated voltage7 ... 32 V DC
Rated current< 1 mA , max. 25 mA
Electrical specifications
Output rated operating current3.2 ... 25 mA
Supplyloop power for field devices
voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V
Input
Connection- 5 wires, 600 mm long, exiting from male thread NPT1/2
- 1 external grounding point
HART communication
ProtocolHART 7.1, backward compatible
Number of devicesup to 8 HART field devices (depending on installation)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013+A11:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300 328 V1.8.1:2012
EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012-09
Conformity
Degree of protectionIEC 60529:2013
Ambient conditions
Ambient temperaturetemperature class T5: -40 ... 85 °C (-40 ... 185 °F)
temperature class T6: -40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
MaterialAluminum alloy with polyurethane enamel paint
Mass460 g
Dimensions60.8 x 60.8 x 100 mm (l x w x h)
Data for application in connection with hazardous areas
EU-Type Examination CertificateFM 12 ATEX 0021 X
MarkingEx-Hexagon II 2 G Ex db IIC T6/T5 Gb
Ex-Hexagon II 2 D Ex tb IIIC T95°C Db
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approvalCoc3041762(C)
Approved forClass I, Zone 1, (A)Ex db IIC T6/T5 Gb
Class I, Zone 21, (A)Ex tb IIIC T95°C Db
Class I, Division 1, Groups A - D
Class II, Division 1, Groups E - G
Class III
IECEx approvalIECEx FMG 12.0005X
Approved forEx db IIC T6/T5 Gb
Ex tb IIIC T95°C Db
StandardsIEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013
Розничная цена
1382.1 $ с НДС 131359 с НДС
В корзину
Купить в 1 клик
Каталожный номер: T159381
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Connectable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.1, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialaluminum
Massapprox. 1000 g
Dimensions91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
versions see type code
Data for application in connection with hazardous areas
EC-Type Examination CertificateBVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection, temperature classEx-Hexagon II 2 G Ex ia IIC T4 Gb
Ex-Hexagon II 2 D Ex tb [ia] IIIC T70°C Db IP6x
Directive conformity
Directive 94/9/ECEN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009
International approvals
IECEx approvalBVS 11.0061
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-MKF8
Узнать цену
Каталожный номер: T46566
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Connectable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.1, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
versions see type code
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-MKF8
Узнать цену
Каталожный номер: T155586
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Connectable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.1, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 99/5/ECETSI EN 300328: V1.7.1 (2006-10), ETSI EN 301489-17: V1.2.1 (2002-08), EN 60950:2001
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions91 x 88.5 x 100.6 mm (3.6 x 3.5 x 4 inch) (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
versions see type code
Data for application in connection with hazardous areas
EC-Type Examination CertificateBVS 11 ATEX E 081 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection, temperature classEx-Hexagon II 2 G Ex ia IIC T4 Gb
Directive conformity
Directive 94/9/ECEN 60079-0:2009 , EN 60079-11:2007 , EN 60079-31:2009
International approvals
IECEx approvalBVS 11.0061
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-MKF8
Узнать цену
Каталожный номер: 261308
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
MaterialAluminum
Massapprox. 1000 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 17 ATEX E 029
MarkingEx-Hexagon II 2G Ex ia IIC T4/T3 Gb
Ex-Hexagon II 2D Ex tb [ia] IIIC T70°C Db
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
CSA approval
Control drawing116-0435
IECEx approval
IECEx certificateIECEX BVS 17.0023
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Каталожный номер: 261305
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Каталожный номер: 261306
Supply
Rated voltage7.2 V DC , battery operated
Electrical specifications
Output rated operating current4 ... 20 mA
Supplyloop power for field devices
voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Input
Suitable field devicesusable for:
- one point-to-point connection with a HART field device, or
- one point-to-point connection with a 4 ... 20 mA field device, or
- up to four externally powered HART field devices operating in multidrop mode
Connectionterminals 1, 2, 3, 4, 5, 6
multiple wirings available , depending on operating mode
Current4 ... 20 mA
HART communication
ProtocolHART 7.3, backward compatible
Number of devices- one passive 4 ... 20 mA/HART field device
- up to 4 HART field devices in multidrop mode
Transfer rate1200 Bit/s
Parametersprimary/secondary master, preambles, retries and short address scan ranges
Output
Output variablesPV: loop current
SV, TV, QV:configurable according to user requirement
- adapter: temperature, battery voltage, energy consumed and estimated battery life-time
- 4 ... 20 mA device: scaled or linearized process value
- HART device: up to four process variables
Transfer characteristics
Accuracycurrent input: 0.125 % of measuring range
Influence of ambient temperaturecurrent input: 5 µA/K
Indicators/settings
Parameter assignment- wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP)
- device variables mapping
- publishing of up to ten burst messages in a wireless network, period and trigger mode selectable
- notification of up to five events from adapter and/or connected device(s) in a wireless network
- scaling and linearization of 4 ... 20 mA signal of connected analog device
- tuning of supply parameters for the connected device
- locking/unlocking of device parameterization
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013, CLASS A
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
FCC CFR47 Part 15 B and CANSI C63.4-2003
RoHs
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Vibration resistance20 ... 2000 Hz, 0,01 g2/Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66
Materialplastic
Massapprox. 750 g
Dimensions92 x 89.5 x 92.8 mm (without cable glands and antenna)
Mountingmounting on field device , panel or pole mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateBVS 17 ATEX E 029
MarkingEx-Hexagon II 2G Ex ia IIC T4/T3 Gb
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
IECEx approval
IECEx certificateIECEX BVS 17.0023
Accessories
Designationbattery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately)
mounting set W-ACC-F8MK
threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Узнать цену
Узнать цену
Каталожный номер: 261332
Описание оборудования
Adapter N socket to N socket
Узнать цену
Каталожный номер: 261330
Описание оборудования
Adapter N socket to TNC socket
Розничная цена
252 $ с НДС 23951 с НДС
В корзину
Купить в 1 клик
Каталожный номер: 261331
Описание оборудования
Adapter N plug to TNC plug
Узнать цену
Каталожный номер: 261329
Описание оборудования
Adapter TNC plug to N socket
Узнать цену
Каталожный номер: 261325
Описание оборудования
Panel antenna for 2.4 GHz band
Узнать цену
Каталожный номер: 228809
Описание оборудования
Rod antenna for 2.4 GHz band
Узнать цену
Каталожный номер: 261324
Описание оборудования
Rod antenna for 2.4 GHz band
Узнать цену
Каталожный номер: 261326
Описание оборудования
Panel antenna for 2.4 GHz band
Узнать цену
Каталожный номер: T32652
Electrical specifications
Currentsee type code
Узнать цену
Каталожный номер: 219035
Electrical specifications
Nominal voltage3.6 V
Nominal current5 mA
Nominal capacity19 Ah , capacity can varies with usage conditions
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature15 ... 30 °C (59 ... 86 °F) recommended
-40 ... 80 °C (-40 ... 176 °F) at accelerated derating
Mechanical specifications
Massapprox. 90 g
DimensionsØ33 x 61,5 mm (1.3 x 2.4 inch)
Розничная цена
118.15 $ с НДС 11230 с НДС
В корзину
Купить в 1 клик
Каталожный номер: 220390
Electrical specifications
Nominal voltage7.2 V
Nominal current250 mA
Nominal capacity19 Ah , capacity can varies with usage conditions
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Storage temperature15 ... 30 °C (59 ... 86 °F) recommended
-40 ... 80 °C (-40 ... 176 °F) at accelerated derating
Mechanical specifications
Massapprox. 285 g
Dimensions75 x 71 x 39 mm (2.95 x 2.8 x 1.5 inch)
Розничная цена
424.15 $ с НДС 40313 с НДС
В корзину
Купить в 1 клик
Каталожный номер: T165088
Описание оборудования
Coaxial cable, N plug to N plug
Узнать цену
Каталожный номер: 227264
Mechanical specifications
Massapprox. 5 g
Dimensions13 x 17 x 7 mm (0.53 x 0.66 x 0.27 inch)
Узнать цену
Каталожный номер: 98190
Описание оборудования
Ballast weight for float switch
Розничная цена
47.23 $ с НДС 4489 с НДС
В корзину
Купить в 1 клик
Каталожный номер: 262204
Описание оборудования
Ballast weight for float switch
Узнать цену
Каталожный номер: 44825
Mechanical specifications
Cable diameter5 ... 12 mm
Materialbrass , PA
Mass160 g
Process connectionG1A
Розничная цена
50.73 $ с НДС 4822 с НДС
В корзину
Купить в 1 клик
Добавлено в корзину!

Товаров: 0

На сумму: 0

Продолжить покупки
Оформить заказ

Интерфейсные решения HART Pepperl+Fuchs (розничные и оптовые цены)

Клиенты

Блог

Подписка

Последнее на форуме

ООО "Зипстор"
127282, Страна, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru