Сортировать по: Название   Цена  
Каталожный номер: 235909
Search characteristics
NetworkTN-C
General specifications
Device typetype 2 acc. to EN 61643-11
class II acc. to IEC 61643-1
Number of protected supply lines3
Suitable componentsprotection module M-LB-1.275.M
Electrical specifications
Nominal voltage230 V AC / 400 V AC
Maximum continuous operating voltagemax. 275 V AC
Temporary over-voltage335 V / 5 s (TOV withstand)
Nominal discharge current (8/20 µs)20 kA
Max. surge current (8/20 µs)40 kA
Voltage protection levelmax. 1.25 kV
max. 1 kV at 5 kA
Reaction timemax. 25 ns
Short-circuit-proof50 kA eff
Overcurrent protectionmax. 125 A gG , mains-side
Fault indication output
Connectionterminals 11, 12, 14
Outputvolt-free change-over contact
Switch powerAC: 250 V / 0.5 A
DC: 250 V/0.1 A 125 V/0.2 A 75 V/0.5 A 24 V/0.5 A
Indicators/settings
Display elementsstatus display
operating state (green)
fault indication (red)
Directive conformity
Low voltage
Directive 2014/35/EUEN 61643-11:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Degree of protectionIP20
Core cross-section- min. 1.5 mm2 solid/flexible
- max. 35 mm2 stranded/25 mm2 flexible
- max. 1.5 mm2 solid/flexible (for remote signalling contact)
Material
Housingthermoplastic, color grey , UL 94 V-0
Massapprox. 360 g
Dimensions54 x 90 x 73 mm (2.1 x 3.6 x 2.9 inch) (3 TE acc. to DIN 43880)
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Узнать цену
Каталожный номер: 235912
Search characteristics
NetworkTN-S
General specifications
Device typetype 2 acc. to EN 61643-11
class II acc. to IEC 61643-1
Number of protected supply lines4
Suitable componentsprotection module M-LB-1.150.M
Electrical specifications
Nominal voltage120 V AC / 240 V AC
Maximum continuous operating voltagemax. 150 V AC
Temporary over-voltage175 V / 5 s (TOV withstand)
Nominal discharge current (8/20 µs)15 kA
Max. surge current (8/20 µs)40 kA
Voltage protection levelmax. 0.7 kV
max. 0.55 kV at 5 kA
Reaction timemax. 25 ns
Short-circuit-proof50 kA eff
Fault indication output
Connectionterminals 11, 12, 14
Outputvolt-free change-over contact
Switch powerAC: 250 V / 0.5 A
DC: 250 V/0.1 A 125 V/0.2 A 75 V/0.5 A 24 V/0.5 A
Indicators/settings
Display elementsstatus display
operating state (green)
fault indication (red)
Directive conformity
Low voltage
Directive 2014/35/EUEN 61643-11:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Degree of protectionIP20
Core cross-section- min. 1.5 mm2 solid/flexible
- max. 35 mm2 stranded/25 mm2 flexible
- max. 1.5 mm2 solid/flexible (for remote signalling contact)
Material
Housingthermoplastic, color grey , UL 94 V-0
Massapprox. 480 g
Dimensions72 x 90 x 73 mm (2.8 x 3.6 x 2.9 inch) (4 TE acc. to DIN 43880)
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Узнать цену
Каталожный номер: 235911
Search characteristics
NetworkTN-S
General specifications
Device typetype 2 acc. to EN 61643-11
class II acc. to IEC 61643-1
Number of protected supply lines4
Suitable componentsprotection module M-LB-1.275.M
Electrical specifications
Nominal voltage230 V AC / 400 V AC
Maximum continuous operating voltagemax. 275 V AC
Temporary over-voltage335 V / 5 s (TOV withstand)
Nominal discharge current (8/20 µs)20 kA
Max. surge current (8/20 µs)40 kA
Voltage protection levelmax. 1.25 kV
max. 1 kV at 5 kA
Reaction timemax. 25 ns
Short-circuit-proof50 kA eff
Overcurrent protectionmax. 125 A gG , mains-side
Fault indication output
Connectionterminals 11, 12, 14
Outputvolt-free change-over contact
Switch powerAC: 250 V / 0.5 A
DC: 250 V/0.1 A 125 V/0.2 A 75 V/0.5 A 24 V/0.5 A
Indicators/settings
Display elementsstatus display
operating state (green)
fault indication (red)
Directive conformity
Low voltage
Directive 2014/35/EUEN 61643-11:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Degree of protectionIP20
Core cross-section- min. 1.5 mm2 solid/flexible
- max. 35 mm2 stranded/25 mm2 flexible
- max. 1.5 mm2 solid/flexible (for remote signalling contact)
Material
Housingthermoplastic, color grey , UL 94 V-0
Massapprox. 480 g
Dimensions72 x 90 x 73 mm (2.8 x 3.6 x 2.9 inch) (4 TE acc. to DIN 43880)
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Узнать цену
Каталожный номер: 235913
Search characteristics
NetworkTT
General specifications
Device typetype 2 acc. to EN 61643-11
class II acc. to IEC 61643-1
Number of protected supply lines4
Suitable componentsprotection module M-LB-1.275.M
protection module M-LB-1.NPE.M
Electrical specifications
Nominal voltage230 V AC / 400 V AC
Maximum continuous operating voltagemax. 275 V AC (L-N)
max. 255 V AC (N-PE)
Temporary over-voltage335 V/5 s (TOV withstand) (L-N)
1200 V/200 ms (TOV withstand) (N-PE)
Nominal discharge current (8/20 µs)20 kA
Max. surge current (8/20 µs)40 kA
Total discharge current (8/20 µs)12 kA (N-PE)
Voltage protection levelmax. 1.25 kV (L-N)
max. 1 kV at 5 kA (L-N)
&le 1.5 kV (N-PE)
Reaction timemax. 25 ns (L-N)
max. 100 ns (N-PE)
Follow current extinguishing capability100 A eff (N-PE)
Short-circuit-proof50 kA eff
Overcurrent protectionmax. 125 A gG , mains-side
Fault indication output
Connectionterminals 11, 12, 14
Outputvolt-free change-over contact
Switch powerAC: 250 V / 0.5 A
DC: 250 V/0.1 A 125 V/0.2 A 75 V/0.5 A 24 V/0.5 A
Indicators/settings
Display elementsstatus display
operating state (green)
fault indication (red)
Directive conformity
Low voltage
Directive 2014/35/EUEN 61643-11:2012
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Degree of protectionIP20
Core cross-section- min. 1.5 mm2 solid/flexible
- max. 35 mm2 stranded/25 mm2 flexible
- max. 1.5 mm2 solid/flexible (for remote signalling contact)
Material
Housingthermoplastic, color grey , UL 94 V-0
Massapprox. 480 g
Dimensions72 x 90 x 73 mm (2.8 x 3.6 x 2.9 inch) (4 TE acc. to DIN 43880)
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Узнать цену
Каталожный номер: 261328
Описание оборудования
&lambda/4 surge protection, N socket to N socket
Узнать цену
Каталожный номер: T46565
Supply
Rated voltage20 ... 30 V DC SELV/PELV
Power consumption< 5 W
External bus
Connectionscrew terminals for
- 0.2 ... 4 mm2 (rigid wire)
- 0.2 ... 2.5 mm2 (flexible wire)
Interface 1Ethernet
10 BASE-T/100 BASE-TX , full galvanic isolation
ProtocolHART UDP, MODBUS TCP
Interface 2RS-485
ProtocolHART, MODBUS RTU
Transfer ratemax. 115 kBit/s
Galvanic isolation
Interface/interfacebasic insulation according to IEC 61140, rated insulation voltage 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328: V2.1.1
EN 301489-17: V1.3.2
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66/IP67
Massapprox. 1 kg
Dimensions258 mm x 114 mm x 84 mm
without antenna and cable glands
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateFM 12 ATEX 0061
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
FM approvalCoc3042646
Approved forNI Class I, Div. 2, GPS A-D
NI Class II, Class III, Div. 2, GPS E-G
IECEx approvalIECEx FMG 12.0002
Approved forEx nA IIC T4 Gc , Ex nAc T4
Узнать цену
Каталожный номер: T162057
Supply
Rated voltage20 ... 30 V DC SELV/PELV
Power consumption< 5 W
External bus
Connectionscrew terminals for
- 0.2 ... 4 mm2 (rigid wire)
- 0.2 ... 2.5 mm2 (flexible wire)
Interface 1Ethernet
10 BASE-T/100 BASE-TX , full galvanic isolation
ProtocolHART UDP, EtherNet/IP
Interface 2RS-485
ProtocolHART
Transfer ratemax. 115 kBit/s
Galvanic isolation
Interface/interfacebasic insulation according to IEC 61140, rated insulation voltage 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Radio and telecommunication terminal equipmentThe usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
Directive 2014/53/EUEN 300328: V2.1.1
EN 301489-17: V1.3.2
FCC CFR47 Part 15 B and CANSI C63.4-2003
Conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
test setup and execution acc. to EN 60068-2-60
Mechanical specifications
Degree of protectionIP66/IP67
Massapprox. 1 kg
Dimensions258 mm x 114 mm x 84 mm
without antenna and cable glands
Mountingpanel mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificateFM 12 ATEX 0061 , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3 G Ex nA nC IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
FM approvalCoc3042646
Approved forNI Class I, Div. 2, GPS A-D
NI Class II, Class III, Div. 2, GPS E-G
IECEx approvalIECEx FMG 12.0002
Approved forEx nA nC IIC T4 Gc
Ex nAc nCc T4