| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 2.5 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 6150 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 18 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 2.5 mm | |
| Length | 3 mm | |
| Measuring cone | ||
| Material | 9S20K | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 2144 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 2.5 mm | |
| Length | 3 mm | |
| Measuring cone | ||
| Material | 9S20K | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 1/8" (3.175mm) | |
| Measuring cone | Carboloy | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Traverse A | 1 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Functional safety related parameters | ||
| MTTFd | 2140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10 | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 20 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 10 mm | |
| Measuring cone | 4 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10 | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Installation | non-flush | |
| Inside diameter | 10 mm | |
| Measuring cylinder | ||
| Diameter | 1/8" (3.175mm) | |
| Measuring cone | Carboloy/high grade steel | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cylinder | 9S20K | |
| Diameter | 3 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 5990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 5990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4305 / AISI 303 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 5990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 18 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cylinder | Fe-metal | |
| Diameter | 3 mm | |
| Length | 4 mm | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Traverse A | 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 2240 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165F | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cylinder | ||
| Diameter | 1/4" (6.250mm) | |
| Measuring cone | Carboloy | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Traverse A | 1 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Functional safety related parameters | ||
| MTTFd | 2240 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 40 °C (32 ... 104 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10 | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 150 mm Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Mass | 20 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cone | 6 mm, 1.4401 | |
| Passage speed | &le 10 m/s | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Power ON | &ge 3 mA with UB = 8 V &ge 4.2 mA at UB = 10 | |
| Functional safety related parameters | ||
| MTTFd | 2130 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 75 °C (-13 ... 167 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m Crimp terminal sockets 60888-3, AMP | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Mass | 36 g | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR, bistable | |
| Inside diameter | 15 mm | |
| Measuring cylinder | ||
| Diameter | 1/4" (6.250mm) | |
| Measuring cone | Carboloy | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Hysteresis | typ. 1 % | |
| Reverse polarity protection | reverse polarity protected | |
| Current consumption | ||
| Traverse B | 3 mA | |
| Passage B UB=8V | &ge 3 mA | |
| Passage B UB=10V | &ge 4.2 mA | |
| Traverse A | 1 mA | |
| Passage A UB=10V | 0.5 ... 1 mA typ. 0.9 mA | |
| Passage A UB=8V | 0.5 ... 0.95 mA typ. 0.8 mA | |
| Functional safety related parameters | ||
| MTTFd | 2240 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP/NPN | |
| Installation | non-flush | |
| Output polarity | DC | |
| Measuring cylinder | ||
| Diameter | 15 mm | |
| Length | 15 mm | |
| Ring diameter | 102 mm | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 20 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | no | |
| Voltage drop | < 1 V | |
| Operating current | 12 mA | |
| Off-state current | 2 µA | |
| Switching state indicator | LED, red | |
| Indicators/operating means | ||
| Potentiometer | sensitivity adjustment , 15 turns | |
| Output | ||
| Load current | 100 mA ( NPN ) 50 mA ( PNP ) | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin micro connector ( M12 x 1 ) | |
| Housing material | ABS | |
| Degree of protection | IP65 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cylinder | 9S20K | |
| Diameter | 3 mm | |
| Length | 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption |   | |
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 10800 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cylinder | 9S20K | |
| Diameter | 3 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Inside diameter | 15 mm | |
| Measuring cylinder | ||
| Diameter | 3 mm | |
| Length | 4 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 1500 Hz | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Functional safety related parameters | ||
| MTTFd | 9340 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Approvals and certificates | ||
| FM approval | ||
| Control drawing | 116-0165 | |
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 2G | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Installation | ||
| Output polarity | DC | |
| Inside diameter | 21 mm | |
| Measuring cylinder | ||
| Diameter | 6 mm | |
| Length | 12 mm | |
| Material | Steel 1.0711 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 20 mA | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Installation | ||
| Output polarity | DC | |
| Inside diameter | 21 mm | |
| Measuring cylinder | ||
| Diameter | 6 mm | |
| Length | 12 mm | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 20 mA | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M12 x 1 , 4-pin , PVC Cable, 100 mm | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Output polarity | DC | |
| Inside diameter | 43 mm | |
| Measuring cylinder | ||
| Diameter | 9 mm | |
| Length | 18 mm | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 500 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 1326 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Frequency range | 0.1 ... 1 Hz , adjustable | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Nominal ratings | ||
| Operating voltage | 15 ... 60 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | LED 1: yellow | |
| Damping indicator | LED 2: yellow | |
| Functional safety related parameters | ||
| MTTFd | 820 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Frequency range | 1 ... 10 Hz , adjustable | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Nominal ratings | ||
| Operating voltage | 15 ... 60 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | LED 1: yellow | |
| Damping indicator | LED 2: yellow | |
| Functional safety related parameters | ||
| MTTFd | 820 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Frequency range | 10 ... 100 Hz , adjustable | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Nominal ratings | ||
| Operating voltage | 15 ... 60 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | LED 1: yellow | |
| Damping indicator | LED 2: yellow | |
| Functional safety related parameters | ||
| MTTFd | 820 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Frequency range | 0.1 ... 1 Hz , adjustable | |
| Rated operating distance | 30 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 24.3 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Nominal ratings | ||
| Operating voltage | 15 ... 60 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | LED 1: yellow | |
| Damping indicator | LED 2: yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Frequency range | 1 ... 10 Hz , adjustable | |
| Rated operating distance | 30 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 24.3 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.85 | |
| Nominal ratings | ||
| Operating voltage | 15 ... 60 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 25 mA | |
| Switching state indicator | LED 1: yellow | |
| Damping indicator | LED 2: yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | screw terminals | |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
| Core cross-section | up to 2.5 mm2 | |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Installation | flush | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |