Каталожный номер: 232395
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationflush
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.32
Reduction factor r304 0.72
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 650 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1870 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 80 °C (-13 ... 176 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Connection typecable PUR (halogen-free) , 15 m , screened , Oil resistant , Flame-retardant as per IEC 60332-1
Core cross-section2x 0.5 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP66 / IP67
Cable
Bending radius> 7.5 x cable diameter
NoteThe shield is not connected to the sensor.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D
Розничная цена
115.4 $ с НДС 10964 с НДС
array(31) { ["id"]=> string(5) "84819" ["product_id"]=> string(6) "141560" ["id_1c"]=> NULL ["sku"]=> string(6) "232395" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(10964) ["primary_price"]=> string(10) "115.407064" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(10964) ["unconverted_price"]=> float(115.4) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 208595
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationflush
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.32
Reduction factor r304 0.72
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 650 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PUR , 15 m
Core cross-section0.75 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP66 / IP67
Cable
Bending radius> 10 x cable diameter
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D
Розничная цена
234.9 $ с НДС 22317 с НДС
array(31) { ["id"]=> string(5) "84820" ["product_id"]=> string(6) "141561" ["id_1c"]=> NULL ["sku"]=> string(6) "208595" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(22317) ["primary_price"]=> string(10) "234.908742" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(22317) ["unconverted_price"]=> float(234.9) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 246522
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationflush
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.35
Reduction factor rCu 0.3
Reduction factor r304 0.75
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 200 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd1870 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 50 m
Core cross-section0.75 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega66 °C (150.8 °F)
using an amplifier in accordance with EN 60947-5-666 °C (150.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
105.4 $ с НДС 10014 с НДС
array(31) { ["id"]=> string(5) "84821" ["product_id"]=> string(6) "141562" ["id_1c"]=> NULL ["sku"]=> string(6) "246522" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(10014) ["primary_price"]=> string(10) "105.407364" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(10014) ["unconverted_price"]=> float(105.4) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181121
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationflush
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.35
Reduction factor rCu 0.3
Reduction factor r304 0.75
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 200 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd1870 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross-section0.75 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega66 °C (150.8 °F)
using an amplifier in accordance with EN 60947-5-666 °C (150.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
118.8 $ с НДС 11287 с НДС
array(31) { ["id"]=> string(5) "84822" ["product_id"]=> string(6) "141563" ["id_1c"]=> NULL ["sku"]=> string(6) "181121" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(11287) ["primary_price"]=> string(10) "118.806962" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(11287) ["unconverted_price"]=> float(118.8) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 243379
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationflush
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.32
Reduction factor r304 0.72
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 650 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1870 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 80 °C (-13 ... 176 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Connection typecable PUR (halogen-free) , 5 m , screened , Oil resistant , Flame-retardant as per IEC 60332-1
Core cross-section2x 0.5 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP66 / IP67
Cable
Bending radius> 7.5 x cable diameter
NoteThe shield is not connected to the sensor.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D
Розничная цена
58.87 $ с НДС 5593 с НДС
array(31) { ["id"]=> string(5) "84823" ["product_id"]=> string(6) "141564" ["id_1c"]=> NULL ["sku"]=> string(6) "243379" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5593) ["primary_price"]=> string(9) "58.871918" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5593) ["unconverted_price"]=> float(58.87) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181119
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationflush
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.35
Reduction factor rCu 0.3
Reduction factor r304 0.75
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 200 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1821 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega66 °C (150.8 °F)
using an amplifier in accordance with EN 60947-5-666 °C (150.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
Plug connectorThe plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
95.85 $ с НДС 9107 с НДС
array(31) { ["id"]=> string(5) "83485" ["product_id"]=> string(6) "140226" ["id_1c"]=> NULL ["sku"]=> string(6) "181119" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(9107) ["primary_price"]=> string(9) "95.860282" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(9107) ["unconverted_price"]=> float(95.85) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 89266
General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V
Switching frequency0 ... 150 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd1830 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PUR , 2 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
97.2 $ с НДС 9235 с НДС
array(31) { ["id"]=> string(5) "84824" ["product_id"]=> string(6) "141565" ["id_1c"]=> NULL ["sku"]=> string(5) "89266" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(9235) ["primary_price"]=> string(8) "97.20761" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(9235) ["unconverted_price"]=> float(97.2) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 211271
General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V DC
Switching frequency0 ... 150 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd1830 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Cable versionPA
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Gc (nA)
Certificate of CompliancePF 15CERT3754 X
Special conditions
Protection against transientsEnsure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
at UBmax=60 V, IL=100 mA50 °C (122 °F)
at UBmax=60 V, IL=50 mA57 °C (134.6 °F)
at UBmax=60 V, IL=25 mA60 °C (140 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category3G 3D
Розничная цена
121.5 $ с НДС 11543 с НДС
array(31) { ["id"]=> string(5) "84825" ["product_id"]=> string(6) "141566" ["id_1c"]=> NULL ["sku"]=> string(6) "211271" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(11543) ["primary_price"]=> string(10) "121.501618" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(11543) ["unconverted_price"]=> float(121.5) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 126073
General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm ( -25 ... 70 °C (-13 ... 158 °F) )
0 ... 7.6 mm ( -40 ... -25 °C (-40 ... -13 °F) )
Actual operating distance9 ... 11 mm typ. 10 mm
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V
Switching frequency0 ... 150 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Voltage drop at IL
Voltage drop IL = 20 mA, switching element on3.4 ... 5 V typ. 4.3 V
Operating current2 ... 100 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1830 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
97.2 $ с НДС 9235 с НДС
array(31) { ["id"]=> string(5) "84826" ["product_id"]=> string(6) "141567" ["id_1c"]=> NULL ["sku"]=> string(6) "126073" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(9235) ["primary_price"]=> string(8) "97.20761" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(9235) ["unconverted_price"]=> float(97.2) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 183050
General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ. 10 mm
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V DC
Switching frequency0 ... 150 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Voltage drop at IL
Voltage drop IL = 20 mA, switching element on3.4 ... 5 V typ. 4.3 V
Operating current2 ... 100 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1830 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Equipment protection level Gc (nA)
Certificate of CompliancePF 15CERT3754 X
Special conditions
Protection against transientsEnsure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
at UBmax=60 V, IL=100 mA55 °C (131 °F)
at UBmax=60 V, IL=50 mA60 °C (140 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
Plug connectorThe plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)
General information
Use in the hazardous areasee instruction manuals
Category3G 3D
Розничная цена
121.5 $ с НДС 11543 с НДС
array(31) { ["id"]=> string(5) "84827" ["product_id"]=> string(6) "141568" ["id_1c"]=> NULL ["sku"]=> string(6) "183050" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(11543) ["primary_price"]=> string(10) "121.501618" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(11543) ["unconverted_price"]=> float(121.5) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 89270
General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V
Switching frequency0 ... 150 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorall direction LED, yellow
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PUR , 2 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
97.2 $ с НДС 9235 с НДС
array(31) { ["id"]=> string(5) "84828" ["product_id"]=> string(6) "141569" ["id_1c"]=> NULL ["sku"]=> string(5) "89270" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(9235) ["primary_price"]=> string(8) "97.20761" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(9235) ["unconverted_price"]=> float(97.2) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 211272
General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V DC
Switching frequency0 ... 150 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorall direction LED, yellow
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Cable versionPA
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Gc (nA)
Certificate of CompliancePF 15CERT3754 X
Special conditions
Protection against transientsEnsure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
at UBmax=60 V, IL=100 mA53 °C (127.4 °F)
at UBmax=60 V, IL=50 mA58 °C (136.4 °F)
at UBmax=60 V, IL=25 mA61 °C (141.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category3G 3D
Розничная цена
121.5 $ с НДС 11543 с НДС
array(31) { ["id"]=> string(5) "84829" ["product_id"]=> string(6) "141570" ["id_1c"]=> NULL ["sku"]=> string(6) "211272" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(11543) ["primary_price"]=> string(10) "121.501618" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(11543) ["unconverted_price"]=> float(121.5) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 89271
General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 60 V
Switching frequency0 ... 150 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorMultihole-LED, yellow
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Узнать цену
Каталожный номер: 293464
General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ. 10 mm
Reduction factor rAl 0.32
Reduction factor rCu 0.32
Reduction factor r304 0.72
Reduction factor rBrass 0.43
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V
Switching frequency300 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le 2.8 V
Voltage drop at IL
Voltage drop IL = 10 mA, switching element on0.9 ... 2.4 V typ. 1.7 V
Voltage drop IL = 20 mA, switching element on0.9 ... 2.4 V typ. 1.7 V
Voltage drop IL = 50 mA, switching element on0.9 ... 2.5 V typ. 1.7 V
Voltage drop IL = 100 mA, switching element on1 ... 2.6 V typ. 1.8 V
Voltage drop IL = 200 mA, switching element on1.2 ... 2.8 V typ. 2 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 0.01 mA
No-load supply current&le 20 mA
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typeflexible leads LiYV , 200 mm
Core cross-section0.5 mm2
Housing materialCrastin (PBTB)
Sensing facePBT
Degree of protectionIP67
Розничная цена
213.57 $ с НДС 20290 с НДС
array(31) { ["id"]=> string(5) "84831" ["product_id"]=> string(6) "141572" ["id_1c"]=> NULL ["sku"]=> string(6) "293464" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(20290) ["primary_price"]=> string(9) "213.57254" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(20290) ["unconverted_price"]=> float(213.57) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 184673
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationflush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.28
Reduction factor rCu 0.25
Reduction factor r304 0.75
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega)
Switching frequency0 ... 400 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd5128 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typescrew terminals
Core cross-section&le 2.5 mm2
Housing materialPBT/metal
Sensing facePBT
Degree of protectionIP68
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 1D
Розничная цена
130.28 $ с НДС 12377 с НДС
array(31) { ["id"]=> string(5) "84832" ["product_id"]=> string(6) "141573" ["id_1c"]=> NULL ["sku"]=> string(6) "184673" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(12377) ["primary_price"]=> string(10) "130.280302" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(12377) ["unconverted_price"]=> float(130.275) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 184674
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationflush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.28
Reduction factor rCu 0.25
Reduction factor r304 0.75
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega)
Switching frequency0 ... 400 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd5128 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialPBT/metal
Sensing facePBT
Degree of protectionIP68
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 1D
Розничная цена
68.77 $ с НДС 6534 с НДС
array(31) { ["id"]=> string(5) "84833" ["product_id"]=> string(6) "141574" ["id_1c"]=> NULL ["sku"]=> string(6) "184674" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(6534) ["primary_price"]=> string(9) "68.776884" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(6534) ["unconverted_price"]=> float(68.77) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181091
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationquasi flush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.33
Reduction factor rCu 0.29
Reduction factor r304 0.76
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 450 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd3068 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.75 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP66 / IP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
CertificatePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega58 °C (136.4 °F)
using an amplifier in accordance with EN 60947-5-658 °C (136.4 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
95.85 $ с НДС 9107 с НДС
array(31) { ["id"]=> string(5) "83486" ["product_id"]=> string(6) "140227" ["id_1c"]=> NULL ["sku"]=> string(6) "181091" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(9107) ["primary_price"]=> string(9) "95.860282" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(9107) ["unconverted_price"]=> float(95.85) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 204727
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationquasi flush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.33
Reduction factor rCu 0.29
Reduction factor r304 0.76
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 450 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd3068 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 10 m
Core cross-section0.75 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
CertificatePF 15CERT3774 X
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega58 °C (136.4 °F)
using an amplifier in accordance with EN 60947-5-658 °C (136.4 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
127.58 $ с НДС 12120 с НДС
array(31) { ["id"]=> string(5) "84834" ["product_id"]=> string(6) "141575" ["id_1c"]=> NULL ["sku"]=> string(6) "204727" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(12120) ["primary_price"]=> string(9) "127.57512" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(12120) ["unconverted_price"]=> float(127.575) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 204726
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationquasi flush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.33
Reduction factor rCu 0.29
Reduction factor r304 0.76
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 450 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd3068 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross-section0.75 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
CertificatePF 15CERT3774 X
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega58 °C (136.4 °F)
using an amplifier in accordance with EN 60947-5-658 °C (136.4 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
118.8 $ с НДС 11287 с НДС
array(31) { ["id"]=> string(5) "84835" ["product_id"]=> string(6) "141576" ["id_1c"]=> NULL ["sku"]=> string(6) "204726" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(11287) ["primary_price"]=> string(10) "118.806962" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(11287) ["unconverted_price"]=> float(118.8) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181092
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance15 mm
Installationquasi flush
Assured operating distance0 ... 12.15 mm
Actual operating distance13.5 ... 16.5 mm typ.
Reduction factor rAl 0.33
Reduction factor rCu 0.29
Reduction factor r304 0.76
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 450 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd3068 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Core cross-section-
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
CertificatePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega58 °C (136.4 °F)
using an amplifier in accordance with EN 60947-5-658 °C (136.4 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.
Plug connectorThe plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)
General information
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
95.85 $ с НДС 9107 с НДС
array(31) { ["id"]=> string(5) "83487" ["product_id"]=> string(6) "140228" ["id_1c"]=> NULL ["sku"]=> string(6) "181092" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(9107) ["primary_price"]=> string(9) "95.860282" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(9107) ["unconverted_price"]=> float(95.85) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 127392
General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance15 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 12 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.4
Reduction factor r304 0.7
Reduction factor rBrass 0.5
Nominal ratings
Operating voltage3.5 ... 30 V
Switching frequency500 Hz
Hysteresistyp. 5%
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le 3.5 V
Temperature drift± 15%
Operating current2 ... 100 mA
Off-state currenttyp. 0.8 mA
Switching state indicatorLED, yellow
Pre-fault indicatorLED, red
Stability control-switch point0,8 sr ... 0,9 sr
Functional safety related parameters
MTTFd1390 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
53.52 $ с НДС 5085 с НДС
array(31) { ["id"]=> string(5) "84836" ["product_id"]=> string(6) "141577" ["id_1c"]=> NULL ["sku"]=> string(6) "127392" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5085) ["primary_price"]=> string(8) "53.52471" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5085) ["unconverted_price"]=> float(53.52) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 131622
General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance15 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 12 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.4
Reduction factor r304 0.7
Reduction factor rBrass 0.5
Nominal ratings
Operating voltage3.5 ... 30 V
Switching frequency500 Hz
Hysteresistyp. 5%
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le 3.5 V
Temperature drift± 15%
Operating current2 ... 100 mA
Off-state currenttyp. 0.8 mA
Switching state indicatorLED, yellow
Pre-fault indicatorLED, red
Stability control-switch point0,8 sr ... 0,9 sr
Functional safety related parameters
MTTFd1390 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
53.52 $ с НДС 5085 с НДС
array(31) { ["id"]=> string(5) "84837" ["product_id"]=> string(6) "141578" ["id_1c"]=> NULL ["sku"]=> string(6) "131622" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5085) ["primary_price"]=> string(8) "53.52471" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5085) ["unconverted_price"]=> float(53.52) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 182912
General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance15 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 12 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.4
Reduction factor r304 0.7
Reduction factor rBrass 0.5
Nominal ratings
Operating voltage3.5 ... 30 V
Switching frequency500 Hz
Reverse polarity protectionreverse polarity-conductive
Short-circuit protectionpulsing
Voltage drop&le 3.5 V
Temperature drift± 15%
Operating current2 ... 100 mA
Off-state currenttyp. 0.8 mA
Switching state indicatorLED, yellow
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
53.52 $ с НДС 5085 с НДС
array(31) { ["id"]=> string(5) "84838" ["product_id"]=> string(6) "141579" ["id_1c"]=> NULL ["sku"]=> string(6) "182912" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5085) ["primary_price"]=> string(8) "53.52471" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5085) ["unconverted_price"]=> float(53.52) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 182913
General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance15 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 12 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.4
Reduction factor r304 0.7
Reduction factor rBrass 0.5
Nominal ratings
Operating voltage3.5 ... 30 V
Switching frequency500 Hz
Reverse polarity protectionreverse polarity-conductive
Short-circuit protectionpulsing
Voltage drop&le 3.5 V
Temperature drift± 15%
Operating current2 ... 100 mA
Off-state currenttyp. 0.8 mA
Switching state indicatorLED, yellow
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
53.52 $ с НДС 5085 с НДС
array(31) { ["id"]=> string(5) "84839" ["product_id"]=> string(6) "141580" ["id_1c"]=> NULL ["sku"]=> string(6) "182913" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5085) ["primary_price"]=> string(8) "53.52471" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5085) ["unconverted_price"]=> float(53.52) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 182914
General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance15 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 12 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.4
Reduction factor r304 0.7
Reduction factor rBrass 0.5
Nominal ratings
Operating voltage3.5 ... 30 V
Switching frequency500 Hz
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le 3.5 V
Temperature drift± 15%
Operating current2 ... 100 mA
Off-state currenttyp. 0.8 mA
Switching state indicatorLED, yellow
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter30 mm
Degree of protectionIP67
Розничная цена
53.52 $ с НДС 5085 с НДС
array(31) { ["id"]=> string(5) "84840" ["product_id"]=> string(6) "141581" ["id_1c"]=> NULL ["sku"]=> string(6) "182914" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5085) ["primary_price"]=> string(8) "53.52471" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5085) ["unconverted_price"]=> float(53.52) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181169
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.2
Reduction factor rCu 0.1
Reduction factor r304 0.5
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega)
Switching frequency0 ... 1000 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd2490 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialPBT
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP67
Cable
Bending radius> 12 x cable diameter
General information
Use in the hazardous areasee instruction manuals
Category2G 1D
Розничная цена
56.16 $ с НДС 5336 с НДС
array(31) { ["id"]=> string(5) "84841" ["product_id"]=> string(6) "141582" ["id_1c"]=> NULL ["sku"]=> string(6) "181169" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5336) ["primary_price"]=> string(9) "56.166736" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5336) ["unconverted_price"]=> float(56.16) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181094
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.23
Reduction factor rCu 0.21
Reduction factor r304 0.7
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega)
Switching frequency0 ... 1000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorall direction LED, yellow
Functional safety related parameters
MTTFd2698 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP66 / IP67
Cable
Bending radius> 12 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega61 °C (141.8 °F)
using an amplifier in accordance with EN 60947-5-661 °C (141.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
56.16 $ с НДС 5336 с НДС
array(31) { ["id"]=> string(5) "83488" ["product_id"]=> string(6) "140229" ["id_1c"]=> NULL ["sku"]=> string(6) "181094" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5336) ["primary_price"]=> string(9) "56.166736" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5336) ["unconverted_price"]=> float(56.16) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181097
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.23
Reduction factor rCu 0.21
Reduction factor r304 0.7
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 1000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorall direction LED, yellow
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 10 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP67
Cable
Bending radius> 12 x cable diameter
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
Certificate of CompliancePF 15CERT3774 X
CE marking[*PD-Z02585A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
Special conditions
Minimum series resistance RVA minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxValues can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv.
at UBmax=9 V, RV=562 &Omega61 °C (141.8 °F)
using an amplifier in accordance with EN 60947-5-661 °C (141.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Protection of the connection cableThe connection cable must be prevented from being subjected to tension and torsional loading.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up.
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
89.1 $ с НДС 8465 с НДС
array(31) { ["id"]=> string(5) "84842" ["product_id"]=> string(6) "141583" ["id_1c"]=> NULL ["sku"]=> string(6) "181097" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(8465) ["primary_price"]=> string(8) "89.10259" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(8465) ["unconverted_price"]=> float(89.1) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181096
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.23
Reduction factor rCu 0.21
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega)
Switching frequency0 ... 1000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le 1 mA
Switching state indicatorall direction LED, yellow
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Cable
Bending radius> 12 x cable diameter
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals
Category1G 2G 3G 1D 3D
Розничная цена
78.3 $ с НДС 7439 с НДС
array(31) { ["id"]=> string(5) "84843" ["product_id"]=> string(6) "141584" ["id_1c"]=> NULL ["sku"]=> string(6) "181096" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(7439) ["primary_price"]=> string(9) "78.302914" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(7439) ["unconverted_price"]=> float(78.3) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Каталожный номер: 181099
General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ.
Reduction factor rAl 0.23
Reduction factor rCu 0.21
Reduction factor r304 0.7
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega)
Operating voltage5 ... 25 V
Switching frequency0 ... 1000 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected&ge 2.2 mA
Measuring plate detected&le 1 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd2698 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP66 / IP67
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals
Category1G 2G 1D
Розничная цена
58.05 $ с НДС 5515 с НДС
array(31) { ["id"]=> string(5) "83489" ["product_id"]=> string(6) "140230" ["id_1c"]=> NULL ["sku"]=> string(6) "181099" ["sort"]=> string(1) "0" ["name"]=> string(0) "" ["image_id"]=> NULL ["price"]=> float(5515) ["primary_price"]=> string(8) "58.05089" ["purchase_price"]=> float(0) ["compare_price"]=> float(0) ["count"]=> string(5) "0.000" ["available"]=> string(1) "1" ["stock_base_ratio"]=> NULL ["order_count_min"]=> NULL ["order_count_step"]=> NULL ["status"]=> string(1) "1" ["dimension_id"]=> NULL ["file_name"]=> string(0) "" ["file_size"]=> string(1) "0" ["file_description"]=> NULL ["virtual"]=> string(1) "0" ["ymleasyimport_price_id"]=> NULL ["id_xmlimport"]=> NULL ["stock"]=> array(3) { [1]=> string(5) "0.000" [3]=> string(5) "0.000" [4]=> string(5) "0.000" } ["unconverted_currency"]=> string(3) "USD" ["currency"]=> string(3) "RUB" ["frontend_price"]=> float(5515) ["unconverted_price"]=> float(58.05) ["frontend_compare_price"]=> float(0) ["unconverted_compare_price"]=> float(0) }
В корзину
Купить в 1 клик
Добавлено в корзину!

Товаров: 0

На сумму: 0

Продолжить покупки
Оформить заказ

Клиенты

Блог

Подписка

Последнее на форуме

ООО "Зипстор"
127282, RU, Московская область, Москва, ул. Полярная, 33, стр. 3
+7 (800) 551-66-17
info@zipstore.ru