| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 25 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 20.25 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 19 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.8 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | &le 10 µA | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General information | ||
| Scope of delivery | 2 hex nuts included | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.5 | |
| Reduction factor r304 | 0.75 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M8 x 1 , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 8 mm | |
| Degree of protection | IP67 | |
| General information | ||
| Scope of delivery | 2 hex nuts included | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.5 | |
| Reduction factor r304 | 0.75 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 8 mm | |
| Degree of protection | IP67 | |
| General information | ||
| Scope of delivery | 2 hex nuts included | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 8 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 6.48 mm | |
| Reduction factor rAl | 0.39 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.45 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 450 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 16 mA | |
| Switching state indicator | all direction LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |
| General information | ||
| Scope of delivery | 2 hex nuts included | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 8 mm | |
| Installation | non-flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
| Reduction factor rAl | 0.39 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.45 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 450 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 16 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |
| General information | ||
| Scope of delivery | 2 hex nuts included | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.6 ... 2.6 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | up to 2.5 mm2 | |
| Connection (valve side) | Cage tension spring terminals | |
| Core cross-section (valve side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP20 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.6 ... 2.6 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Core cross-section (system side) | up to 2.5 mm2 | |
| Core cross-section (valve side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP20 | |
| Note | Installation in housing | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.6 ... 2.6 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP20 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.6 ... 2.6 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP20 | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.45 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Reduction factor rBrass | 0.63 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.7 ... 3.3 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.45 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Reduction factor rBrass | 0.63 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow can be switched off by of DB1 | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | up to 2.5 mm2 | |
| Connection (valve side) | Cage tension spring terminals | |
| Core cross-section (valve side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| General information | ||
| Use in the hazardous area | see instruction manual | |
| Category | 1G 2G 3G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally closed (NC) | |
| Output type | NAMUR | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.6 ... 2.6 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.2 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow can be switched off by of DB1 | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection (system side) | screw terminals | |
| Core cross-section (system side) | up to 2.5 mm2 | |
| Connection (valve side) | screw terminals | |
| Core cross-section (valve side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Note | Installation in housing | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G | |
| General specifications | ||
|---|---|---|
| Switching function | 2 x normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 3 mm | |
| Installation | flush mountable | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 2.43 mm | |
| Actual operating distance | 2.6 ... 2.6 mm typ. | |
| Reduction factor rAl | 0.5 | |
| Reduction factor r304 | 1 | |
| Reduction factor rSt37 | 1.1 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 100 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 25 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Valve status indicator | LED, yellow | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection (system side) | Cage tension spring terminals | |
| Core cross-section (system side) | up to 2.5 mm2 | |
| Connection (valve side) | Cage tension spring terminals | |
| Core cross-section (valve side) | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Degree of protection | IP20 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Slot width | 3 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Installation | ||
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Operating current | 0 ... 200 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Core cross-section | 3 x 0.14 mm2 | |
| Housing material | PA 6.6 | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 4 ... 6 typ. 6 mm | |
| Installation | ||
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 6 ... 30 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Hysteresis | 0.15 ... 0.6 mm | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | yes | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Housing material | PA 6.6 | |
| Degree of protection | IP67 | |
| Mass | 18 g | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Slot width | 2 mm | |
| Depth of immersion (lateral) | 5 ... 7 | |
| Installation | non-flush | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 5 ... 30 V DC | |
| Switching frequency | 0 ... 2000 Hz | |
| Hysteresis | 0 ... 0.05 mm | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 4.9 V | |
| Operating current | 2 ... 50 mA | |
| Off-state current | 0 ... 0.5 mA typ. | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads LIFYW , 500 mm | |
| Core cross-section | 0.06 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0.1 ... 0.4 mm | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 500 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | Crastin (PBTB) | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm | |
| Output polarity | DC | |
| Assured operating distance | ||
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0.1 ... 0.4 mm | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Cable connector M8 x 1 , 4-pin , cable: PVC , L = 500 mm ± 5 mm | |
| Housing material | Crastin (PBTB) | |
| Degree of protection | IP67 | |
| General information | ||
| Scope of delivery | screw M 1.7 x 10 , nut M1.7 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm | |
| Output polarity | DC | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0 ... 0.6 mm | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 7 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads LiY , 500 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Installation | ||
| Output polarity | DC | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0.1 ... 0.4 mm | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 7 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads LiY , 500 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Installation | ||
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 65 mm PVC cord with DuPont connector | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm | |
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 2000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 135 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Installation | ||
| Output polarity | DC | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 2000 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2590 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 2 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm , typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 5000 Hz | |
| Hysteresis | 0.11 ... 0.2 mm | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 5790 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 500 mm | |
| Core cross-section | 0.06 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 2 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 5000 Hz | |
| Hysteresis | 0 ... 0.05 mm | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 500 mm | |
| Core cross-section | 0.06 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm , typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0.41 ... 0.6 mm | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 5880 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 135 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0 ... 0.6 mm | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 6 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8 V | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0 ... 0.6 mm | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 400 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Cable | ||
| Bending radius | > 10 x cable diameter | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0.21 ... 0.4 mm | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | min. 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 4968 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads LiY , 500 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 3G 1D | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | NAMUR | |
| Slot width | 3.5 mm | |
| Depth of immersion (lateral) | 5 ... 7 mm , typ. 6 mm | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Nominal voltage | 8.2 V (Ri approx. 1 k&Omega) | |
| Operating voltage | 5 ... 25 V | |
| Switching frequency | 0 ... 3000 Hz | |
| Hysteresis | 0.11 ... 0.2 mm | |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
| Current consumption | ||
| Measuring plate not detected | &ge 3 mA | |
| Measuring plate detected | &le 1 mA | |
| Switching state indicator | LED, yellow | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
| Electromagnetic compatibility | NE 21:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | flexible leads PVC , 500 mm | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PBT | |
| Degree of protection | IP67 | |
| Equipment protection level Da | ||
| Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EU-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
| General information | ||
| Use in the hazardous area | see instruction manuals | |
| Category | 1G 2G 1D | |