Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 10 m | |
| Cable version | PA | |
| Core cross-section | 0.75 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 1/2"-20 UN , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.81 | |
| Output type | 2-wire | |
| Nominal ratings | ||
| Operating voltage | 20 ... 253 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Voltage drop | < 5 V (IL > 50 mA) < 8 V (IL < 50 mA) | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 5 ... 200 mA | |
| Off-state current | 0 ... 1.7 mA | |
| Operating voltage indicator | LED, green | |
| Switching state indicator | LED, yellow | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector 7/8 inch-16 UN , 3-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm | |
| Reduction factor rAl | 0.4 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.4 | |
| Nominal ratings | ||
| Installation conditions | ||
| B | 25 mm | |
| C | 16 mm | |
| F | 37 mm | |
| Operating voltage | 15 ... 30 V | |
| Switching frequency | 0 ... 300 Hz | |
| Hysteresis | 0.05 ... 2.2 mm | |
| Reverse polarity protection | yes | |
| Short-circuit protection | no | |
| Overload resistance | no | |
| Wire breakage protection | yes | |
| Inductive overvoltage protection | yes | |
| Surge suppression | yes | |
| Ripple | 10 % | |
| Voltage drop | &le 8 V | |
| Repeat accuracy | 0.3 mm | |
| Operating current | 2 ... 25 mA | |
| Lowest operating current | 2 mA | |
| No-load supply current | &le 1.5 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.25 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Mass | 145 g | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1050 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1050 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 5 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 7.6 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.15 | |
| Reduction factor r304 | 0.66 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 20 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1140 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Описание оборудования | ||
|---|---|---|
| Inductive sensor | ||
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm typ. 10 mm | |
| Reduction factor rAl | 0.36 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.67 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 1 ... 10 typ. 6 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.8 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1881 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PMMA | |
| Sensing face | PMMA | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm typ. 10 mm | |
| Reduction factor rAl | 0.36 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.67 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 1 ... 10 typ. 6 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.8 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1881 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PMMA | |
| Sensing face | PMMA | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 8.1 mm | |
| Actual operating distance | 9 ... 11 mm typ. 10 mm | |
| Reduction factor rAl | 0.36 | |
| Reduction factor rCu | 0.31 | |
| Reduction factor r304 | 0.67 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V DC | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | 1 ... 10 typ. 6 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2.8 V | |
| Operating current | 0 ... 100 mA | |
| No-load supply current | 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1935 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.14 mm2 | |
| Housing material | PMMA | |
| Sensing face | PMMA | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | Two-wire | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.82 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 250 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | no | |
| Voltage drop | &le 8 V | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 1.5 ... 200 mA | |
| No-load supply current | &le 1.7 mA | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | terminal compartment | |
| Core cross-section | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | AC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.33 | |
| Reduction factor rCu | 0.28 | |
| Reduction factor r304 | 0.82 | |
| Nominal ratings | ||
| Operating voltage | 20 ... 250 V | |
| Switching frequency | 0 ... 20 Hz | |
| Hysteresis | typ. 5 % | |
| Short-circuit protection | no | |
| Voltage drop | &le 8 V | |
| Momentary current (20 ms, 0.1 Hz) | 0 ... 1600 mA | |
| Operating current | 1.5 ... 200 mA | |
| No-load supply current | &le 1.7 mA | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | terminal compartment | |
| Core cross-section | up to 2.5 mm2 | |
| Housing material | PBT | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse &le 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | all direction LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2090 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2090 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | all direction LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2090 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally closed (NC) | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 150 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 100 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2090 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.8 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1733 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 126 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 7 ... 30 V | |
| Switching frequency | 0 ... 1400 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1494 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP68 / IP69K | |
| Mass | 121 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.8 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1733 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 90 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.8 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1733 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 126 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.5 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 1000 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 1.8 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | Multihole-LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1733 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Mass | 90 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 7 ... 30 V | |
| Switching frequency | 0 ... 1400 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1494 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP68 / IP69K | |
| Mass | 135 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 7 ... 30 V | |
| Switching frequency | 0 ... 1400 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1494 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP68 / IP69K | |
| Mass | 115 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 7 ... 30 V | |
| Switching frequency | 0 ... 1400 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1494 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP68 / IP69K | |
| Mass | 135 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | complementary | |
| Output type | PNP | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 4-wire | |
| Nominal ratings | ||
| Operating voltage | 7 ... 30 V | |
| Switching frequency | 0 ... 1400 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 2 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 4 µA at 25 °C | |
| No-load supply current | &le 10 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 1494 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP68 / IP69K | |
| Mass | 115 g | |
| General information | ||
| Scope of delivery | 2 self locking nuts in scope of delivery | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.3 | |
| Reduction factor r304 | 0.75 | |
| Nominal ratings | ||
| Operating voltage | 10 ... 30 V | |
| Switching frequency | 0 ... 200 Hz | |
| Hysteresis | typ. 5% | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | &le 3 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 0.1 µA at 25 °C | |
| No-load supply current | &le 15 mA | |
| Switching state indicator | all direction LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 990 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | cable PVC , 2 m | |
| Core cross-section | 0.34 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP67 | |
| General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | NPN | |
| Rated operating distance | 15 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 ... 12.15 mm | |
| Reduction factor rAl | 0.45 | |
| Reduction factor rCu | 0.4 | |
| Reduction factor r304 | 0.7 | |
| Reduction factor rBrass | 0.5 | |
| Output type | 3-wire | |
| Nominal ratings | ||
| Operating voltage | 5 ... 60 V | |
| Switching frequency | 0 ... 600 Hz | |
| Hysteresis | typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Inductive overvoltage protection | yes | |
| Surge suppression | yes | |
| Voltage drop | &le 2 V | |
| Rated insulation voltage | 60 V | |
| Operating current | 0 ... 200 mA | |
| Off-state current | 0 ... 0.5 mA typ. 6 µA at 25 °C | |
| No-load supply current | &le 7 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 830.5 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | cable PUR , 2 m | |
| Core cross-section | 3 x 0.75 mm2 | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Housing diameter | 30 mm | |
| Degree of protection | IP68 / IP69K | |
| Mass | 190 g | |
Товаров: 0