| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Analog output | ||
| Output type | voltage output 0 ... 10 V | |
| Load resistor | &ge 2000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 2 m PUR cable , screened | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Analog output | ||
| Output type | voltage output 0 ... 10 V | |
| Load resistor | &ge 2000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 4-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Interface | ||
| Interface type | IO-Link | |
| Mode | COM 2 (38.4 kBaud) | |
| Value range | 0000h ... 7000h | |
| Analog output | ||
| Output type | voltage output 0 ... 5 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 4-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.4 mm | |
| No-load supply current | &le 20 mA | |
| Operating voltage indicator | LED | |
| Functional safety related parameters | ||
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 2000 &Omega | |
| Short-circuit protection | limited to 6 mA | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M8 x 1 connector, 3-pin | |
| Housing material | diecast zinc, not laquered or coated | |
| Degree of protection | IP67 | |
| Material | ||
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | PNP | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Voltage drop | &le 3 V | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 880 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Switching output | ||
| Output type | PNP (2 Channels) | |
| Operating current | per channel 50 mA , Combined max. 80 mA | |
| Switching window | position programmable, width 2 mm | |
| Switching hysteresis | 0.4 mm | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5 x 0.14 mm2 , screened 2 m PUR cable | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 95 g | |
| General specifications | ||
|---|---|---|
| Switching element function | PNP | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Voltage drop | &le 3 V | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 880 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Switching output | ||
| Output type | PNP (2 Channels) | |
| Operating current | per channel 50 mA , Combined max. 80 mA | |
| Switching window | position programmable, width 2 mm | |
| Switching hysteresis | 0.4 mm | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Male cordset, M12 , 5-pin 1 m, PUR cable, shielded | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 75 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | current limit | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5 x 0.14 mm2 , screened 2 m PUR cable | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 95 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.3 mm (With a target distance of 0.5 mm) | |
| No-load supply current | &le 20 mA | |
| Functional safety related parameters | ||
| MTTFd | 830 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | current limit | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Male cordset, M12 , 5-pin 1 m, PUR cable, shielded | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 75 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.4 mm | |
| No-load supply current | &le 20 mA | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | Male cordset, M12 , 5-pin 1 m, PUR cable | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 71 g | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 2 mm | |
| Measurement range | 0 ... 14 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | ± 0.05 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.4 mm | |
| No-load supply current | &le 20 mA | |
| Analog output | ||
| Output type | 1 voltage output: 0 ... 10 V | |
| Load resistor | &ge 1000 &Omega | |
| Short-circuit protection | pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Ambient conditions | ||
| Ambient temperature | -10 ... 70 °C (14 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 1 m, PUR cable | |
| Core cross-section | 5 x 0.25 mm2 | |
| Material | ||
| Housing | Zinc die-casting, nickel-plated cover , PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Mass | 65 g | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 210 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.2 mm | |
| Resolution | 210 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 310 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing length L | 250 mm | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PA 6 / AL | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 360 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.2 mm | |
| Resolution | 360 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 210 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing length L | 400 mm | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PA 6 / AL | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog current output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 40 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 60 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 202 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | current output 4 ... 20 mA | |
| Load resistor | current output &le 500 &Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog voltage output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 40 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | &le 60 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 202 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | voltage output 0 ... 10 V | |
| Load resistor | voltage output: &ge 1000 &Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | PBT | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 510 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.6 mm | |
| Repeat accuracy | ± 0.5 mm | |
| Resolution | 550 µm | |
| Temperature drift | ± 0.7 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 65 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 165 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing length L | 550 mm | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PA 6 / AL | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. | |
| General specifications | ||
|---|---|---|
| Switching element function | Analog current output with PNP binary NO | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 80 mm | |
| Linearity range | 1 ... 79 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 125 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | &le 100 mA | |
| Switching window | ± 1 mm | |
| Switching hysteresis | 0.4 mm | |
| Voltage drop | &le 3 V | |
| Short-circuit protection | pulsing | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA | |
| Load resistor | &le 400 &Omega | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | ABS | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | 0.5 ... 3 mm , recommended: 2 mm | |
| Measurement range | 0 ... 80 mm | |
| Linearity range | 1 ... 79 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm | |
| Repeat accuracy | ± 0.1 mm | |
| Resolution | 125 µm | |
| Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 40 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 419 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Degree of protection | IP67 | |
| Material | ||
| Housing | ABS | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 810 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V DC | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.8 mm | |
| Repeat accuracy | ± 0.4 mm | |
| Resolution | 950 µm | |
| Temperature drift | ± 1 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 70 mA | |
| Operating voltage indicator | LED green | |
| Functional safety related parameters | ||
| MTTFd | 120 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | 4-pin, M12 x 1 connector | |
| Housing length L | 850 mm | |
| Degree of protection | IP65 | |
| Material | ||
| Housing | PA 6 / AL | |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. The path measurement system must be secured at 20 cm intervals to prevent mechanical load. | |
| General specifications | ||
|---|---|---|
| Switching element function | analog, current or voltage output | |
| Object distance | max. 6 mm | |
| Measurement range | 0 ... 960 mm | |
| Nominal ratings | ||
| Operating voltage | 18 ... 30 V | |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.9 mm | |
| Repeat accuracy | ± 0.4 mm | |
| Resolution | 960 µm | |
| Temperature drift | ± 0.9 mm (-25 °C ... 70 °C) | |
| No-load supply current | &le 70 mA | |
| Operating voltage indicator | LED green | |
| Analog output | ||
| Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V | |
| Load resistor | current output: &le 400 &Omega voltage output: &ge 1000 &Omega | |
| Short-circuit protection | voltage output: pulsing | |
| Compliance with standards and directives | ||
| Standard conformity | ||
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Mechanical specifications | ||
| Connection type | M12 connector | |
| Housing material | PA 6 / AL | |
| Housing length L | 1000 mm | |
| Degree of protection | IP65 | |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6  mm. The path measurement system must be secured at 20 cm intervals to prevent mechanical load. | |
| Описание оборудования | ||
|---|---|---|
| WCS CANopen interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS Ethernet interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS INTERBUS-S interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS parallel interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS parallel interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS SSI interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS SSI interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS SSI interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS SSI interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS Profibus interface module | ||
| Описание оборудования | ||
|---|---|---|
| WCS-Interface module with PROFINET interface | ||
Товаров: 0
На сумму: 0