| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub) | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 50 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit prtected (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 100 °C (-40 ... 212 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 280 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 35 gcm2 | |
| Starting torque | &le 1 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub) | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 100 °C (-40 ... 212 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 280 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 35 gcm2 | |
| Starting torque | &le 1 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 50 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 100 °C (-40 ... 212 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 280 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 35 gcm2 | |
| Starting torque | &le 1 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F) , fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F) , fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 350 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 25 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 40 N at max. 6000 min-1 10 N at max. 12000 min-1 | |
| Radial | 60 N at max. 6000 min-1 20 N at max. 12000 min-1 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F) , fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F) , fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 350 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 25 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 40 N at max. 6000 min-1 10 N at max. 12000 min-1 | |
| Radial | 60 N at max. 6000 min-1 20 N at max. 12000 min-1 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 50 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F) , fixed cable | |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F) , fixed cable | |
| Storage temperature | ||
| Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 350 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 25 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 40 N at max. 6000 min-1 10 N at max. 12000 min-1 | |
| Radial | 60 N at max. 6000 min-1 20 N at max. 12000 min-1 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 2500 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 50 E+9 at 1750 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC or 5 V DC ± 5 % (see "Output circuit" in the ordering information) | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in the ordering information) | |
| Voltage drop | < 2.5 V (push-pull, incremental) | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected (push-pull, incremental) max. per channel 20 mA , short-circuit protected, reverse polarity protected (RS 422, incremental) | |
| Output frequency | max. 200 kHz | |
| Rise time | 600 ns | |
| De-energized delay | 600 ns | |
| Connection | ||
| Connector | M23 connector, 12-pin , clockwise rotation M23 connector, 12-pin , counter clockwise rotation | |
| Cable | &empty6.5 mm, 4 x 2 x 0.14 mm2 | |
| Terminal compartment | Cable duct for cable diameter &empty4 mm ... 13 mm | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP66, IP67 or IP69K 1) | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
| Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
| Ambient conditions | ||
| Operating temperature | -40 ... 80 °C (-40 ... 176 °F) fixed cable | |
| Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | 3.1645 aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 2200 g | |
| Rotational speed | max. 3000 min -1 1) | |
| Starting torque | &le 10 Ncm | |
| Shaft load | ||
| Axial | &le 300 N | |
| Radial | &le 400 N | |
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 2500 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 50 E+9 at 1750 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC or 5 V DC ± 5 % (see "Output circuit" in the ordering information) | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in the ordering information) | |
| Voltage drop | < 2.5 V (push-pull, incremental) | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected (push-pull, incremental) max. per channel 20 mA , short-circuit protected, reverse polarity protected (RS 422, incremental) | |
| Output frequency | max. 200 kHz | |
| Rise time | 600 ns | |
| De-energized delay | 600 ns | |
| Connection | ||
| Connector | M23 connector, 12-pin , clockwise rotation M23 connector, 12-pin , counter clockwise rotation | |
| Cable | &empty6.5 mm, 4 x 2 x 0.14 mm2 | |
| Terminal compartment | Cable duct for cable diameter &empty4 mm ... 13 mm | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP66, IP67 or IP69K 1) | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
| Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
| Ambient conditions | ||
| Operating temperature | -40 ... 80 °C (-40 ... 176 °F) fixed cable | |
| Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | 3.1645 aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 2200 g | |
| Rotational speed | max. 3000 min -1 1) | |
| Starting torque | &le 10 Ncm | |
| Shaft load | ||
| Axial | &le 300 N | |
| Radial | &le 400 N | |
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Cable | &empty6.5 mm, 4 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub) | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Cable | &empty6.5 mm, 4 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 50 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Cable | &empty6.5 mm, 4 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 1024 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Cable | 200 mm cable with M12 connector, 8-pin | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -30 ... 60 °C (-4 ... 140 °F), fixed cable | |
| Storage temperature | ||
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 290 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | &le 40 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit prtected (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 280 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 35 gcm2 | |
| Starting torque | &le 1 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub) | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 280 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 35 gcm2 | |
| Starting torque | &le 1 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 50 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP54 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 280 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 35 gcm2 | |
| Starting torque | &le 1 Ncm | |
| Shaft load | ||
| Angle offset | 1 ° | |
| Axial offset | max. 1 mm | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 60 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 3 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 400 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F) , fixed cable -40 ... 80 °C (-40 ... 176 °F) with Option T , fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 350 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 25 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 40 N at max. 6000 min-1 10 N at max. 12000 min-1 | |
| Radial | 60 N at max. 6000 min-1 20 N at max. 12000 min-1 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 70 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F) , fixed cable -40 ... 80 °C (-40 ... 176 °F) with Option T , fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 350 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 25 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 40 N at max. 6000 min-1 10 N at max. 12000 min-1 | |
| Radial | 60 N at max. 6000 min-1 20 N at max. 12000 min-1 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 50000 | |
| Functional safety related parameters | ||
| MTTFd | 140 a | |
| Mission Time (TM) | 20 a | |
| L10h | 70 E+9 at 6000 rpm | |
| Diagnostic Coverage (DC) | 0 % | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 50 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected | |
| Output frequency | max. 200 kHz | |
| Rise time | 100 ns | |
| Connection | ||
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin or M12 connector, 8-pin | |
| Cable | &empty7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F) , fixed cable -40 ... 80 °C (-40 ... 176 °F) with Option T , fixed cable | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 350 g | |
| Rotational speed | max. 12000 min -1 | |
| Moment of inertia | &le 25 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 40 N at max. 6000 min-1 10 N at max. 12000 min-1 | |
| Radial | 60 N at max. 6000 min-1 20 N at max. 12000 min-1 | |
| General specifications | ||
|---|---|---|
| Pulse count | max. 5000 | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 80 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 4 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 100 kHz | |
| Rise time | 250 ns | |
| De-energized delay | 250 ns | |
| Connection | ||
| Connector | type 42306 (M16), 6-pin type 42308 (M16), 8-pin type 9414 (M16), 5-pin type 9416 (M23), 12-pin | |
| Cable | &empty6 mm, 4 x 2 x 0.14 mm2, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -20 ... 70 °C (-4 ... 158 °F) | |
| Plastic disk | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | ||
| Glass disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Plastic disk | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical specifications | ||
| Material | ||
| Combination 1 | housing: diecast zinc flange: aluminum 3.1645 shaft: stainless steel 1.4305 / AISI 303 | |
| Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
| Mass | approx. 335 g (combination 1) approx. 1400 g (combination 2) | |
| Rotational speed | max. 10000 min -1 | |
| Moment of inertia | &le 30 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 60 N | |
| Radial | 80 N | |
| General specifications | ||
|---|---|---|
| Pulse count | max. 5000 | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 150 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof | |
| Output frequency | max. 100 kHz | |
| Rise time | 100 ns | |
| De-energized delay | 100 ns | |
| Connection | ||
| Connector | type 42306 (M16), 6-pin type 42308 (M16), 8-pin type 9414 (M16), 5-pin type 9416 (M23), 12-pin | |
| Cable | &empty6 mm, 4 x 2 x 0.14 mm2, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -20 ... 70 °C (-4 ... 158 °F) | |
| Plastic disk | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | ||
| Glass disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Plastic disk | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical specifications | ||
| Material | ||
| Combination 1 | housing: diecast zinc flange: aluminum 3.1645 shaft: stainless steel 1.4305 / AISI 303 | |
| Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
| Mass | approx. 335 g (combination 1) approx. 1400 g (combination 2) | |
| Rotational speed | max. 10000 min -1 | |
| Moment of inertia | &le 30 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 60 N | |
| Radial | 80 N | |
| General specifications | ||
|---|---|---|
| Pulse count | max. 5000 | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 150 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof, reverse polarity protected | |
| Output frequency | max. 100 kHz | |
| Rise time | 100 ns | |
| De-energized delay | 100 ns | |
| Connection | ||
| Connector | type 42306 (M16), 6-pin type 42308 (M16), 8-pin type 9414 (M16), 5-pin type 9416 (M23), 12-pin | |
| Cable | &empty6 mm, 4 x 2 x 0.14 mm2, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -20 ... 70 °C (-4 ... 158 °F) | |
| Plastic disk | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | ||
| Glass disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Plastic disk | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical specifications | ||
| Material | ||
| Combination 1 | housing: diecast zinc flange: aluminum 3.1645 shaft: stainless steel 1.4305 / AISI 303 | |
| Combination 2 (Inox) | housing: stainless steel flange: stainless steel shaft: stainless steel | |
| Mass | approx. 335 g (combination 1) approx. 1400 g (combination 2) | |
| Rotational speed | max. 10000 min -1 | |
| Moment of inertia | &le 30 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 60 N | |
| Radial | 80 N | |
| General specifications | ||
|---|---|---|
| Pulse count | 1024 | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 80 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 4 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 100 kHz | |
| Rise time | 250 ns | |
| De-energized delay | 250 ns | |
| Connection | ||
| Cable | &empty6 mm, 4 x 2 x 0.14 mm2, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP65 | |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Glass disk | -20 ... 70 °C (-4 ... 158 °F) | |
| Plastic disk | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | ||
| Glass disk | -40 ... 70 °C (-40 ... 158 °F) | |
| Plastic disk | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical specifications | ||
| Material | housing: diecast zinc flange: aluminum 3.1645 shaft: stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 335 g | |
| Rotational speed | max. 10000 min -1 | |
| Moment of inertia | &le 30 gcm2 | |
| Starting torque | &le 1.5 Ncm | |
| Shaft load | ||
| Axial | 60 N | |
| Radial | 80 N | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 80 mA | |
| Interface | ||
| Resolution | ||
| Overall resolution | ||
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 4 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 100 kHz | |
| Rise time | 250 ns | |
| De-energized delay | 250 ns | |
| Connection | ||
| Cable | &empty11.2 mm, 9-core, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP66 | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Ambient conditions | ||
| Operating temperature |   | |
| Gas Ex-area | -40 ... 55 °C (-40 ... 131 °F) | |
| Dust Ex-area | -30 ... 55 °C (-22 ... 131 °F) | |
| Storage temperature | ||
| Gas Ex-area | -40 ... 70 °C (-40 ... 158 °F) | |
| Dust Ex-area | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical specifications | ||
| Material |   | |
| Housing | 3.1645 aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 3000 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | 400 gcm2 | |
| Starting torque | < 5 Ncm | |
| Shaft load |   | |
| Axial | 60 N | |
| Radial | 80 N | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ZELM 02 ATEX 0078 X | |
| Group, category, type of protection | II 2G Ex db IIC T6 Gb II 2D Ex tb IIIC T80°C Db IP66 | |
| Directive conformity | ||
| Directive 94/9/EC | EN 60079-0:2012 EN 60079-1:2007 EN 60079-31:2009 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 150 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof | |
| Output frequency | max. 100 kHz | |
| Rise time | 100 ns | |
| De-energized delay | 100 ns | |
| Connection | ||
| Cable | &empty11.2 mm, 9-core, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP66 | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Ambient conditions | ||
| Operating temperature | ||
| Gas Ex-area | -40 ... 55 °C (-40 ... 131 °F) | |
| Dust Ex-area | -30 ... 55 °C (-22 ... 131 °F) | |
| Storage temperature | ||
| Gas Ex-area | -40 ... 70 °C (-40 ... 158 °F) | |
| Dust Ex-area | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | 3.1645 aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 3000 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | 400 gcm2 | |
| Starting torque | < 5 Ncm | |
| Shaft load | ||
| Axial | 60 N | |
| Radial | 80 N | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ZELM 02 ATEX 0078 X | |
| Group, category, type of protection | II 2G Ex db IIC T6 Gb II 2D Ex tb IIIC T80°C Db IP66 | |
| Directive conformity | ||
| Directive 94/9/EC | EN 60079-0:2012 EN 60079-1:2007 EN 60079-31:2009 | |
| General specifications | ||
|---|---|---|
| Detection type | photoelectric sampling | |
| Pulse count | max. 5000 | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 150 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof, reverse polarity protected | |
| Output frequency | max. 100 kHz | |
| Rise time | 100 ns | |
| De-energized delay | 100 ns | |
| Connection | ||
| Cable | &empty11.2 mm, 9-core, 2 m | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP66 | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Ambient conditions | ||
| Operating temperature | ||
| Gas Ex-area | -40 ... 55 °C (-40 ... 131 °F) | |
| Dust Ex-area | -30 ... 55 °C (-22 ... 131 °F) | |
| Storage temperature | ||
| Gas Ex-area | -40 ... 70 °C (-40 ... 158 °F) | |
| Dust Ex-area | -30 ... 70 °C (-22 ... 158 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | 3.1645 aluminum | |
| Flange | 3.1645 aluminum | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 3000 g | |
| Rotational speed | max. 6000 min -1 | |
| Moment of inertia | 400 gcm2 | |
| Starting torque | < 5 Ncm | |
| Shaft load | ||
| Axial | 60 N | |
| Radial | 80 N | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ZELM 02 ATEX 0078 X | |
| Group, category, type of protection | II 2G Ex db IIC T6 Gb II 2D Ex tb IIIC T80°C Db IP66 | |
| Directive conformity | ||
| Directive 94/9/EC | EN 60079-0:2012 EN 60079-1:2007 EN 60079-31:2009 | |
| General specifications | ||
|---|---|---|
| Pulse count | max. 2500 | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | max. 80 mA | |
| Output | ||
| Output type | push-pull, incremental | |
| Voltage drop | < 4 V | |
| Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
| Output frequency | max. 160 kHz | |
| Rise time | 250 ns | |
| De-energized delay | 250 ns | |
| Connection | ||
| Connector | type 9414 (M16), 5-pin | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP40 | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Plastic disk | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | ||
| Plastic disk | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated diecast zinc | |
| Flange | powder coated diecast zinc | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 480 g | |
| Rotational speed | max. 3000 min -1 | |
| Moment of inertia | &le 5 gcm2 | |
| Starting torque | < 0.5 Ncm | |
| Shaft load | ||
| Axial | 10 N | |
| Radial | 10 N | |
| General specifications | ||
|---|---|---|
| Pulse count | max. 2500 | |
| Electrical specifications | ||
| Operating voltage | 5 V DC ± 5 % | |
| No-load supply current | max. 150 mA | |
| Output | ||
| Output type | RS 422, incremental | |
| Load current | max. per channel 20 mA , conditionally short-circuit proof | |
| Output frequency | max. 160 kHz | |
| Rise time | 100 ns | |
| De-energized delay | 100 ns | |
| Connection | ||
| Connector | type 9414 (M16), 5-pin | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP40 | |
| Emitted interference | EN 61000-6-4:2007/A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
| Ambient conditions | ||
| Operating temperature | ||
| Plastic disk | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | ||
| Plastic disk | -40 ... 60 °C (-40 ... 140 °F) | |
| Mechanical specifications | ||
| Material | ||
| Housing | powder coated diecast zinc | |
| Flange | powder coated diecast zinc | |
| Shaft | Stainless steel 1.4305 / AISI 303 | |
| Mass | approx. 480 g | |
| Rotational speed | max. 3000 min -1 | |
| Moment of inertia | &le 5 gcm2 | |
| Starting torque | < 0.5 Ncm | |
| Shaft load | ||
| Axial | 10 N | |
| Radial | 10 N | |