| Описание оборудования | ||
|---|---|---|
| Reflector with Micro-structure, rectangular 82 mm x 60 mm, mounting holes | ||
| Описание оборудования | ||
|---|---|---|
| Reflector with Micro-structure, round ø 21 mm, screw fixing M3 | ||
| Описание оборудования | ||
|---|---|---|
| Reflector with Micro-structure, round ø 21 mm, screw fixing M3 | ||
| Описание оборудования | ||
|---|---|---|
| Reflector with Micro-structure, rectangular 60 mm x 19 mm, mounting holes | ||
| Описание оборудования | ||
|---|---|---|
| Reflector with Micro-structure, rectangular 60 mm x 19 mm, mounting holes | ||
| Описание оборудования | ||
|---|---|---|
| Reflector with mounting holes | ||
| Описание оборудования | ||
|---|---|---|
| Reflector with mounting holes | ||
| Описание оборудования | ||
|---|---|---|
| Reflector, rectangular 120 mm x 51 mm, mounting holes, heatable 24 V DC | ||
| Описание оборудования | ||
|---|---|---|
| Reflector, rectangular 120 mm x 51 mm, mounting holes, heatable 24 V DC | ||
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Degree of protection | IP66 (IP67 with O-ring) | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Degree of protection | IP66 (IP67 with O-ring) | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Degree of protection | IP66 (IP67 with O-ring) | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Glass | thermo-resistant tempered glass | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Glass | thermo-resistant tempered glass | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Degree of protection | IP66 (IP67 with O-ring) | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Glass | thermo-resistant tempered glass | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Enclosure cover | threaded round cover | |
| Cover fixing | flamepath thread | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Glass | thermo-resistant tempered glass | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Grounding | M6 external/M5 internal grounding point | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| Conformity | ||
| Degree of protection | EN 60529 | |
| General information | ||
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Accessories | ||
| Optional accessories | see PDF data sheet | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | ASM enclosure: 500 A max. EJB enclosure: 1600 A max. GUB enclosure: 1000 A max. | |
| Mechanical specifications | ||
| Height | see PDF data sheet | |
| Width | see PDF data sheet | |
| Depth | see PDF data sheet | |
| Fixing holes distance, height | see PDF data sheet | |
| Fixing holes distance, width | see PDF data sheet | |
| Enclosure cover | hinged | |
| Cover fixing | see PDF data sheet | |
| Fixing holes diameter | see PDF data sheet | |
| Degree of protection | see PDF data sheet | |
| Material | ||
| Enclosure | aluminum and stainless steel | |
| Finish | see PDF data sheet | |
| Seal | see PDF data sheet | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | -20/-40 /-50 ... 55 °C (-4/-40/-58 ... 131 °F) details see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | see PDF data sheet | |
| Group, category, type of protection, temperature class | II 2 GDASM enclosures: Ex d IIB Gb, Ex tb IIIC Db EJB enclosures: Ex d IIB+H2 Gb, Ex tb IIIC Db EJB20 / EJB20A in aluminum: Ex d IIB Gb, Ex tb IIIC Db GUB enclosures: Ex d IIC Gb, Ex tb IIIC Db FS* Termination and Control Station: Ex de IIC T6, T5, T4 Gb Ex ib IIC T6, T5, T4 Gb Ex de ib IIC T6, T5, T4 Gb Ex tb IIIC T80 °C, T95 °C, T130 °C Db | |
| International approvals | ||
| IECEx approval | see PDF data sheet | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Glass | thermo-resistant tempered glass | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Grounding | M6 grounding points | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66/67 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | AISI 316L stainless steel | |
| Finish | shot peened | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Grounding | M6 grounding points | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Enclosure cover | threaded round cover | |
| Cover fixing | flamepath thread | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | Aluminum alloy | |
| Glass | thermo-resistant tempered glass | |
| Finish | painted grey | |
| Mass | see PDF data sheet | |
| Grounding | M6 grounding points | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| Conformity | ||
| Degree of protection | EN 60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Accessories | ||
| Optional accessories | see PDF data sheet | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Enclosure cover | threaded round cover | |
| Cover fixing | flamepath thread | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | AISI 316L stainless steel | |
| Finish | shot peened | |
| Mass | see PDF data sheet | |
| Grounding | M6 grounding points | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| Conformity | ||
| Degree of protection | EN 60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Accessories | ||
| Optional accessories | see PDF data sheet | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1000 A max. | |
| Mechanical specifications | ||
| Degree of protection | IP66 (IP67 with O-ring) | |
| Material | ||
| Enclosure | Stainless steel | |
| Ambient conditions | ||
| Ambient temperature | -50 ... 60 °C (-58 ... 140 °F) -20 °C ... 60 °C (-4 °F ... 140 °F) GUB*5* and GUBX*5* | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | INERIS 14 ATEX 0035X | |
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIC Gb Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0042X | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | AISI 316L stainless steel | |
| Finish | shot peened | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Electrical specifications | ||
|---|---|---|
| Operating voltage | 660 V DC / 1000 V AC max. | |
| Operating current | 1600 A max. | |
| Mechanical specifications | ||
| Enclosure cover | detachable , optional hinges | |
| Cover fixing | Stainless steel hexagonal head screws | |
| Degree of protection | IP66/67 (IP67 with O-ring) | |
| Cable entry | see PDF data sheet | |
| Defined entry area | see PDF data sheet | |
| Material | ||
| Enclosure | AISI 316L stainless steel | |
| Glass | thermo-resistant tempered glass | |
| Finish | shot peened | |
| Mass | see PDF data sheet | |
| Mounting | see PDF data sheet | |
| Ambient conditions | ||
| Ambient temperature | see PDF data sheet | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | ||
| Group, category, type of protection, temperature class | [Ex] II 2 GDEx d IIB+H2 Gb (EJB20 / 20 A in aluminum: Ex d IIB) Ex tb IIIC Db | |
| International approvals | ||
| IECEx approval | IECEx INE 14.0029X | |
| Conformity | ||
| Degree of protection | EN60529 | |
| General information | ||
| Ordering information | This Solution will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
| Описание оборудования | ||
|---|---|---|
| Actuator for non-contact AS-Interface Reed safety switch | ||
| Описание оборудования | ||
|---|---|---|
| Actuator for non-contact AS-Interface Reed safety switch | ||
| Описание оборудования | ||
|---|---|---|
| Right-angled actuator for AS-Interface safety switches | ||
| Описание оборудования | ||
|---|---|---|
| Straight actuator for AS-Interface safety switches | ||
| Описание оборудования | ||
|---|---|---|
| Hinged actuator for right/left mounted doors, for AS-Interface safety switches | ||