Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, Gray code | ||
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, Gray code | ||
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, Gray code | ||
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, Gray code | ||
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, Gray code | ||
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, Gray code | ||
| General specifications | ||
|---|---|---|
| Passage speed | &le 12.5 m/s | |
| Measuring range | max. 314.5 m | |
| Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) | |
| Resolution | ± 0.4 mm (1,250 positions/m) | |
| Functional safety related parameters | ||
| MTTFd | 50 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED green: power on | |
| Data flow indicator | LED yellow: data communication active | |
| Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| Power consumption | 2 VA | |
| Interface | ||
| Interface type | CANopen , galvanically isolated | |
| Data output code | binary code | |
| Transfer rate | max. 1 MBit/s | |
| Termination | switchable | |
| Standard conformity | ||
| Emitted interference | DIN EN 61000-6-4 | |
| Noise immunity | DIN EN 61000-6-2 | |
| Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms | |
| Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles | |
| Approvals and certificates | ||
| CSA approval | cCSAus Certified, General Purpose Class 2 power source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Operating temperature | 0 ... 60 °C (32 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | 90 % , noncondensing | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP54 | |
| Material | ||
| Housing | ABS , PC (Polycarbonate) | |
| Mass | 500 g | |
| General information | ||
| Ordering information | Mounting plate included with delivery | |
| General specifications | ||
|---|---|---|
| Passage speed | &le 12.5 m/s | |
| Measuring range | max. 314.5 m | |
| Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) | |
| Resolution | ± 0.4 mm (1,250 positions/m) | |
| Functional safety related parameters | ||
| MTTFd | 50 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED green: power on | |
| Data flow indicator | LED yellow: data communication active | |
| Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed | |
| Display | Display module, 6-digit adaptable to installation position | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| Power consumption | 2 VA | |
| Interface | ||
| Interface type | CANopen , galvanically isolated | |
| Data output code | binary code | |
| Transfer rate | max. 1 MBit/s | |
| Termination | switchable | |
| Standard conformity | ||
| Emitted interference | DIN EN 61000-6-4 | |
| Noise immunity | DIN EN 61000-6-2 | |
| Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms | |
| Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles | |
| Approvals and certificates | ||
| CSA approval | cCSAus Certified, General Purpose Class 2 power source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Operating temperature | 0 ... 60 °C (32 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | 90 % , noncondensing | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP54 | |
| Material | ||
| Housing | ABS , PC (Polycarbonate) | |
| Mass | 500 g | |
| General information | ||
| Ordering information | Mounting plate included with delivery | |
| General specifications | ||
|---|---|---|
| Passage speed | &le 12.5 m/s | |
| Measuring range | max. 314.5 m | |
| Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) | |
| Resolution | ± 0.4 mm (1,250 positions/m) | |
| Functional safety related parameters | ||
| MTTFd | 50 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED green: power on | |
| Data flow indicator | LED yellow: data communication active | |
| Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| Power consumption | 11 VA at 24 V DC | |
| Interface | ||
| Interface type | CANopen , galvanically isolated | |
| Data output code | binary code | |
| Transfer rate | max. 1 MBit/s | |
| Termination | switchable | |
| Standard conformity | ||
| Emitted interference | DIN EN 61000-6-4 | |
| Noise immunity | DIN EN 61000-6-2 | |
| Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms | |
| Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles | |
| Approvals and certificates | ||
| CSA approval | cCSAus Certified, General Purpose Class 2 power source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Operating temperature | -40 ... 60 °C (-40 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | 90 % , noncondensing | |
| Mechanical specifications | ||
| Connection type | 5-pin, M12 x 1 connector | |
| Degree of protection | IP54 | |
| Material | ||
| Housing | ABS , PC (Polycarbonate) | |
| Mass | 500 g | |
| General information | ||
| Ordering information | Mounting plate included with delivery | |
| Описание оборудования | ||
|---|---|---|
| Read head with EtherNet/IP interface | ||
| General specifications | ||
|---|---|---|
| Passage speed | &le 12.5 m/s | |
| Measuring range | max. 314.5 m | |
| Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) | |
| Resolution | ± 0.4 mm (1,250 positions/m) | |
| Functional safety related parameters | ||
| MTTFd | 50 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| LED green | PROFINET link To: PROFINET connection OK | |
| LED yellow | PROFINET RX/TX Flashing: data transfer | |
| LED red | PROFINET communication To: communication error | |
| LED red/green | Status indication Green: code rail detected, normal function Red: system error Flashing red: no code rail detected | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| Power consumption | 6 W | |
| Interface | ||
| Interface type | 100 BASE-TX | |
| Data output code | binary code | |
| Protocol | PROFINET IO Real-Time (RT) Conformance class A | |
| Transfer rate |     100 MBit/s       | |
| Standard conformity | ||
| Emitted interference | EN 61000-6-4:2007+A1:2011     | |
| Noise immunity | EN 61000-6-2:2005     | |
| Shock resistance | EN 60068-2-27:2009 | |
| Vibration resistance | EN 60068-2-6:2008 | |
| Approvals and certificates | ||
| CSA approval | cCSAus Certified, General Purpose Class 2 power source | |
| CCC approval | CCC approval / marking not required for products rated &le36 V | |
| Ambient conditions | ||
| Operating temperature | 0 ... 60 °C (32 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | 90 % , noncondensing | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector, Y-coded | |
| Cable gland | Max. tightening torque of the cap nut: &le 0.4 Nm | |
| Degree of protection | IP54 | |
| Material | ||
| Housing | ABS , PC (Polycarbonate) | |
| Mass | 500 g | |
| General information | ||
| Ordering information | Mounting plate included with delivery | |
| Описание оборудования | ||
|---|---|---|
| Read head, RS-485 interface, with RS-485 termination resistor | ||
| Описание оборудования | ||
|---|---|---|
| Read head, RS-485 interface, with RS-485 termination resistor | ||
| Описание оборудования | ||
|---|---|---|
| Read head, RS-485 interface, with RS-485 termination resistor | ||
| Описание оборудования | ||
|---|---|---|
| Read head, RS-485 interface, with RS-485 termination resistor | ||
| Описание оборудования | ||
|---|---|---|
| Read head, RS-485 interface, with RS-485 termination resistor | ||
| Описание оборудования | ||
|---|---|---|
| Reading head, SSI interface, binary code | ||
| Supply | ||
|---|---|---|
| Connection | X20: terminals 1, 3 (+) 2, 4 (-) | |
| Nominal voltage | 24 V DC SELV/PELV | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 0.5 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Interface | ||
| Type/number | 2 x RS-485 | |
| Redundancy | ||
| Supply | Redundancy available. Each supply is decoupled. | |
| Indicators/settings | ||
| Display elements | LED PWR1 (Termination Board power supply), green LED LED PWR2 (Termination Board power supply), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | ||
| Control side | RS-485 : 1 x screw terminal , black HART : 2 x IDC plug, 34-pin | |
| Supply | pluggable screw terminals , black | |
| Core cross-section | screw terminals: 0.25 ... 1.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 10 % glass fiber reinforced | |
| Mass | approx. 190 g | |
| Dimensions | 50 x 200 x 163 mm (1.97 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Supply | ||
|---|---|---|
| Connection | X20: terminals 1, 3 (+) 2, 4 (-) | |
| Nominal voltage | 24 V DC SELV/PELV | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 0.5 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Interface | ||
| Type/number | 2 x RS-485 | |
| Redundancy | ||
| Supply | Redundancy available. Each supply is decoupled. | |
| Indicators/settings | ||
| Display elements | LED PWR1 (Termination Board power supply), green LED LED PWR2 (Termination Board power supply), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | ||
| Control side | RS-485 : 1 x screw terminal , black HART : 4 x IDC plug, 34-pin | |
| Supply | pluggable screw terminals , black | |
| Core cross-section | screw terminals: 0.25 ... 1.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 10 % glass fiber reinforced | |
| Mass | approx. 210 g | |
| Dimensions | 50 x 200 x 163 mm (1.97 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Supply | ||
|---|---|---|
| Connection | X20: terminals 1, 3 (+) 2, 4 (-) | |
| Nominal voltage | 24 V DC SELV/PELV | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 0.5 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Interface | ||
| Type/number | 2 x RS-485 | |
| Redundancy | ||
| Supply | Redundancy available. Each supply is decoupled. | |
| Indicators/settings | ||
| Display elements | LED PWR1 (Termination Board power supply), green LED LED PWR2 (Termination Board power supply), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | ||
| Control side | RS-485 : 1 x screw terminal , black HART : 4 x IDC plug, 34-pin | |
| Supply | pluggable screw terminals , black | |
| Core cross-section | screw terminals: 0.25 ... 1.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 10 % glass fiber reinforced | |
| Mass | approx. 210 g | |
| Dimensions | 50 x 200 x 163 mm (1.97 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 3.15 A , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: fixed screw terminals control side: PCS-specified connector RS 485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 700 g | |
| Dimensions | without HiDMux2700: 333 x 125 x 79 mm (13.1 x 4.9 x 3.1 inch) with Mux2700: 333 x 125 x 208 mm (13.1 x 4.9 x 8.2 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC | |
| Fusing | 2 A , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 64 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | HART loop interface: connectors depending on version RS-485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 152 x 121 x 53 mm (6 x 4.75 x 2.1 inch) with HiDMux2700: 152 x 121 x 142 mm (6 x 4.75 x 5.6 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 3.15 A , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: fixed screw terminals control side: fixed screw terminals RS 485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 222 x 122 x 79 mm (8.7 x 4.8 x 3.1 inch) with HiDMux2700: 222 x 122 x 208 mm (8.7 x 4.8 x 8.2 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 100 mA , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: screw terminals control side: screw terminals/Sub-D socket 2 x 37-pin RS 485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 700 g | |
| Dimensions | without HiDMux2700: 300 x 127 x 72 mm (11.8 x 5 x 2.84 inch) with HiDMux2700: 300 x 127 x 186 mm (11.8 x 5 x 7.3 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 315 mA , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: 2 x 37-pin Sub-D socket control side: 4 x 26-pin connectors RS 485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 260 x 120 x 57 mm (10.2 x 4.7 x 2.84 inch) with HiDMux2700: 260 x 120 x 190 mm (10.2 x 4.7 x 7.5 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 315 mA , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: 5.08 mm removable screw terminals control side: 50-pin Centronics plug RS-485 interface: 5.08 mm removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 333 x 127 x 57 mm (13.1 x 5 x 2.84 inch) with HiDMux2700: 333 x 127 x 190 mm (13.1 x 5 x 7.5 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 315 mA , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: 5.08 mm removable screw terminals control side: 50-pin Centronics plug RS-485 interface: 5.08 mm removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 307 x 120 x 57 mm (12.1 x 4.7 x 2.84 inch) with HiDMux2700: 307 x 120 x 190 mm (12.1 x 4.7 x 7.5 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC | |
| Fusing | 315 mA , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: 5.08 mm removable screw terminals control side: 50-pin Centronics plug RS-485 interface: 5.08 mm removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 333 x 127 x 57 mm (13.1 x 5 x 2.84 inch) with HiDMux2700: 333 x 127 x 190 mm (13.1 x 5 x 7.5 inch) | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 3.15 A , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: screw terminals control side: 56-pin Elco connector RS 485 interface: removable screw terminals power: removable screw terminals | |
| Mass | approx. 500 g | |
| Dimensions | without HiDMux2700: 256 x 125 x 79 mm (10 x 4.9 x 3.1 inch) with HiDMux2700: 256 x 125 x 208 mm (10 x 4.9 x 8.2 inch) | |
| Mounting | DIN rail mounting | |
Товаров: 0