| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 150 x 200 x 163 mm (5.9 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 150 x 200 x 163 mm (5.9 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 150 x 200 x 163 mm (5.9 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Configuration | jumper SW1: card selection - position 1: DI card 3564 - position 2: n.c. (factory setting) - position 3: DI card 3504E  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 150 x 200 x 163 mm (5.9 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 150 x 200 x 163 mm (5.9 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 50-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 550 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 550 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 550 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 490 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 550 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 490 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 50-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 490 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 490 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 490 g | |
| Dimensions | 205 x 175 x 153 mm (8.1 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Connection | X20: terminals 3, 5 (+) 4, 6 (-) | |
| Nominal voltage | 24 V DC , in consideration of rated voltage of used isolators | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the isolators is decoupled, monitored and fused. | |
| Fault indication output | ||
| Connection | X20: terminals 1, 2 | |
| Output type | volt-free contact | |
| Contact loading | 30 V DC, 1 A | |
| Indicators/settings | ||
| Display elements | LED PWR1 (Termination Board power supply), green LED LED PWR2 (Termination Board power supply), green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | ||
| Field side | explosion hazardous area: 4 screw terminals per module , blue | |
| Control side | non-explosion hazardous area: 4 screw terminals per module , black | |
| Supply | pluggable screw terminals , black | |
| Core cross-section | screw terminals: 0.25 ... 1.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 10 % glass fiber reinforced | |
| Mass | approx. 980 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | CESI 11 ATEX 062 | |
| Marking |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Connection | X20: terminals 3, 5 (+) 4, 6 (-) | |
| Nominal voltage | 24 V DC , in consideration of rated voltage of used isolators | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the isolators is decoupled, monitored and fused. | |
| Fault indication output | ||
| Connection | X20: terminals 1, 2 | |
| Output type | volt-free contact | |
| Contact loading | 30 V DC, 1 A | |
| Indicators/settings | ||
| Display elements | LED PWR1 (Termination Board power supply), green LED LED PWR2 (Termination Board power supply), green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | ||
| Field side | explosion hazardous area: 4 screw terminals per module , blue | |
| Control side | non-explosion hazardous area: 2 37-pin Sub-D connector | |
| Supply | pluggable screw terminals , black | |
| Core cross-section | screw terminals: 0.25 ... 1.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 10 % glass fiber reinforced | |
| Mass | approx. 870 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EU-Type Examination Certificate | CESI 11 ATEX 062 | |
| Marking |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1600 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1600 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1600 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A , in each case for 8 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Configuration | jumper SW1/SW2: card selection - position 1: DI card 3564 - position 2: n.c. (factory setting) - position 3: DI card 3504E  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 600 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): ELCO socket, 56-pin  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1600 g | |
| Dimensions | 300 x 200 x 163 mm (11.8 x 7.9 x 6.42 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 32 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 50-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 860 g | |
| Dimensions | 310 x 175 x 153 mm (12.2 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A , in each case for 16 modules | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (Termination Board power supply) - LED power supply I, green LED - LED power supply II, green LED LED FAULT (fault indication), red LED - LED lits: module failure - LED flashes: power supply failure  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2011 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): spring terminals, blue  safe area connection (control side): Yokogawa system connector, 40-pin  | |
| Core cross-section | spring terminals:  rigid: 0.2 ... 2.5 mm2 flexible: 0.25 ... 1.5 mm2  | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 860 g | |
| Dimensions | 310 x 175 x 153 mm (12.2 x 6.9 x 6.02 inch) | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-26:2007 , EN 50303:2000 | |
| International approvals | ||
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 20 ... 30 V DC | |
| Fusing | 100 mA , 5 x 20 mm (0.2 x 0.8 inch) | |
| Power dissipation | 0.7 W , with Multiplexer | |
| Reverse polarity protection | yes | |
| HART signal channels (intrinsically safe) | ||
| HART signal channels | ||
| Number of channels | 32 unbalanced signal loops | |
| Redundancy | ||
| Supply | yes | |
| Galvanic isolation | ||
| HART signal channels | 30 V DC | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
| Relative humidity | 5 ... 90 %, non-condensing | |
| Mechanical specifications | ||
| Core cross-section | 2.5 mm2 (16 AWG) | |
| Connection | field side: screw terminals control side: screw terminals/Sub-D socket 2 x 37-pin RS 485 interface: removable screw terminals power: removable screw terminals  | |
| Mass | approx. 700 g | |
| Dimensions | without HiDMux2700: 300 x 127 x 72 mm (11.8 x 5 x 2.84 inch) with HiDMux2700: 300 x 127 x 186 mm (11.8 x 5 x 7.3 inch)  | |
| Mounting | DIN rail mounting | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): 37-pin Sub-D connector (male)  | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 900 g | |
| Dimensions | 273 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 06 ATEX 022 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| UL approval | ||
| Control drawing | 116-0327 | |
| IECEx approval | IECEx CES 06.0003 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): 37-pin Sub-D connector (male)  | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 900 g | |
| Dimensions | 273 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 06 ATEX 022 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| UL approval | ||
| Control drawing | 116-0327 | |
| IECEx approval | IECEx CES 06.0003 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): 37-pin Sub-D connector (male)  | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 500 g | |
| Dimensions | 201 x 155 x 153 mm (7.9 x 6.1 x 6.0 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): 37-pin Sub-D connector (male)  | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1000 g | |
| Dimensions | 357 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED  | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description.  | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue  safe area connection (control side): 37-pin Sub-D connector (male)  | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1000 g | |
| Dimensions | 357 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection |   II (1)G [Ex ia Ga] IIC   II (1)D [Ex ia Da] IIIC   I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC  [Ex ia Da] IIIC [Ex ia Ma] I  | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Fusing | T3A15 | |
| Electrical specifications | ||
| volt-free fault indication output | 30 V DC, 1 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |