Атол 30Ф не включается (заводской брак)
Валерий
14 января 2022
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 900 g | |
| Dimensions | 273 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 06 ATEX 022 | |
| Group, category, type of protection | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| UL approval | ||
| Control drawing | 116-0327 | |
| IECEx approval | IECEx CES 06.0003 | |
| Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 2 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 500 g | |
| Dimensions | 201 x 155 x 153 mm (7.9 x 6.1 x 6.0 inch) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1000 g | |
| Dimensions | 357 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I | |
| Supply | ||
|---|---|---|
| Connection | terminal block TB3 (1-, 2+ 3-, 4+) | |
| Rated voltage | 24 V DC , in consideration of rated voltage of used isolated barriers | |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered | |
| Ripple | &le 10 % | |
| Fusing | 4 A | |
| Power dissipation | &le 500 mW , without modules | |
| Reverse polarity protection | yes | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Indicators/settings | ||
| Display elements | LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2012 For further information see system description. | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | hazardous area connection (field side): pluggable screw terminals, blue safe area connection (control side): 37-pin Sub-D connector (male) | |
| Core cross-section | 0.2 ... 2.5 mm2 (24 ... 12 AWG) | |
| Material | housing: polycarbonate, 30 % glass fiber reinforced | |
| Mass | approx. 1000 g | |
| Dimensions | 357 x 155 x 153 mm (L x W x H) , height including module assembly | |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
| Data for application in connection with hazardous areas | ||
| EC-Type Examination Certificate | CESI 11 ATEX 062 | |
| Group, category, type of protection | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I | |
| Safe area | ||
| Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) | |
| Galvanic isolation | ||
| Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
| Directive conformity | ||
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 50303:2000 | |
| International approvals | ||
| CSA approval | ||
| Control drawing | see control drawing of correspoding modules | |
| IECEx approval | IECEx CES 11.0022 | |
| Approved for | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Fusing | T3A15 | |
| Electrical specifications | ||
| volt-free fault indication output | 30 V DC, 1 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Directive conformity | ||
|---|---|---|
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Directive conformity | ||
|---|---|---|
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Fusing | T3A15 | |
| Electrical specifications | ||
| volt-free fault indication output | 30 V DC, 1 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Directive conformity | ||
|---|---|---|
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Rated current | &le 100 mA per channel , total current consumption depends on number and type of devices | |
| Fusing | T2A | |
| Electrical specifications | ||
| volt-free fault indication output | 30 V DC, 1 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Fusing | T2A | |
| Electrical specifications | ||
| volt-free fault indication output | 30 V DC, 1 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Directive conformity | ||
|---|---|---|
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC | |
| Fusing | T2A | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Fusing | T2A | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC SELV/PELV | |
| Rated current | &le 0.6 A per channel , total current consumption depends on number and type of devices | |
| Fusing | 6.3 A | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Supply | ||
|---|---|---|
| Rated voltage | 24 V DC | |
| Rated current | &le 0.6 A | |
| Fusing | 6.3 A | |
| Electrical specifications | ||
| volt-free fault indication output | max. 30 V AC/40 V DC, 2 A | |
| Redundancy | ||
| Supply | Redundancy available. The supply for the modules is decoupled, monitored and fused. | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Directive conformity | ||
|---|---|---|
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Degree of protection | IEC 60529 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -15 ... 50 °C (5 ... 122 °F) | |
| Storage temperature | -15 ... 55 °C (5 ... 131 °F) | |
| Relative humidity | &le 95 % , non-condensing | |
| Shock resistance | 1 g , 16 ms (all space directions) | |
| Vibration resistance | < 15 Hz, amplitude ± 2.5 mm/15 Hz | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
Товаров: 0